background image

IMPORTANT SAFETY INSTRUCTIONS

This machine is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops

and offices other than normal residential housekeeping purposes.

When using any electrical appliance, basic precautions should always be followed, including the following:

NOTE

: Read all instructions before using this machine.

  WARNING!

To reduce the risk of fire, electric shock, or injury:

Do not leave the maching unattended when it is plugged in.  Unplug the unit from the outlet when not in use

and before servicing.

To avoid electric shock, do not expose to rain or snow.  Store, and use, indoors.

Do not allow to be used as a toy.  Close attention is necessary when used near children.

Use only as described in this manual.  Use only the manufacturer’s recommended attachments.

Do not use with damaged cord or plug.  If the machine is not working as it should, has been dropped,

damaged, left outdoors or dropped into water, return it to a service center.

Do not pull by the cord, use the cord as a handle, close a door on the cord, or pull the cord around sharp

edges or corners.  Do not run the machine over the cord.  Keep the cord away from heated surfaces.

Do not unplug by pulling on the cord.  To unplug, grasp the plug, not the cord.

Do not handle the plug, the cord or the machine with wet hands.

Do not put any object into openings.  Do not use with any opening blocked; keep free of dust, lint, hair, and

anything that may reduce air flow.

Keep loose clothing, hair, fingers, and all parts of body away from openings and moving parts.

Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes, or any

health endangering dusts.

Turn off all controls before unplugging.

Use extra care when cleaning on stairs.

Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may

be present.

Connect to a properly grounded outlet only.  See Grounding Instructions.

Liquid ejected at the spray nozzle could be dangerous as a result of its temperature, pressure or chemical

content

.

INTRODUCTION

This manual will help you get the most from your COBRA-H2 Extractor

.

  Read these instructions thoroughly

before operating the machine.  This product is intended for commercial use only.

PARTS AND SERVICE

Call the distributor from whom you purchased your machine when you need parts or service.  Please

specify the Model and Serial Number when discussing your machine.

UNCRATING

When the machine is delivered, carefully inspect the shipping carton and the machine for damage.  If damage

is evident, save the shipping carton so that it can be inspected.  Contact the shipping company immediately

for instructions on how to file a freight damage claim.

SERIAL NUMBER PLATE

The Serial Number of your machine is shown on the plate that is mounted on the floor of the base

compartment.  This serial number and model are needed when ordering replacement parts for the machine.

Use the space below to note the Model and Serial Number of your machine for future reference.

MODEL :    COBRA-H2-CSA                     SERIAL NUMBER : _____________________________________
Be sure to register your warranty.  Go to 

www.usproducts.com

.

Содержание COBRA-H2

Страница 1: ...arly monthly or more often to prevent a build up of minerals or chemicals in the pump and heat systems Follow the flush with a clear water rinse to remove any particles and to rinse the acid from the...

Страница 2: ...hair fingers and all parts of body away from openings and moving parts Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes or any health endangering dusts Turn o...

Страница 3: ...has a grounding plug that looks like the plug illustrated in Figure 1 below A temporary adapter illustrated in Figures 2 and 3 may be used to connect this plug to a 2 pole receptacle as shown in Figu...

Страница 4: ...where the vacuum hose attaches to the machine Latch 6 Open the latches to access the base compartment which contains the motors and heater Drain Gate 7 Open this gate to drain the recovered solution...

Страница 5: ...nutes to reach operating temperature 6 Turn the pump on Turn the vacuum on NOTE the pump has a built in pressure switch the pump runs only when you are spraying 7 Begin cleaning using the correct hose...

Страница 6: ...seals are damaged Internal vacuum hose is cracked Recovery tank lid is not closed is cracked or gasket is damaged Recovery tank is warped or cracked Debris impeding air movement on vac motor impellor...

Страница 7: ...1 22 40 41 42 43 44 45 46 47 53 48 55 49 58 50 51 52 62 69 14 16 66 67 68 COBRA H2 CSA 08 10 2007 19 56 24 11 12 13 14 33 28 32 35 63 38 37 30 65 61 60 59 58 69 57 55 54 53 36 31 34 22 25 26 29 27 31...

Страница 8: ...Heat Exchanger complete 36 5 Bolt 1 4 20 X 3 4 37 8 Lock nut 1 4 20 38 455 Bracket heater mount 39 76 Hose Clamp 40 270 Bolt 1 4 20 X 5 41 137 Washer split lock 42 136 Nut finish 1 4 43 14 Washer fla...

Страница 9: ...les mois ou plus souvent pour emp cher le d p t de min raux ou de produits chimiques dans les syst mes de pompe et de chauffage Rincer apr s le lavage avec de l eau claire pour liminer les particules...

Страница 10: ...les cheveux les doigts et tout autre partie du corps loin des ouvertures et des pi ces mobiles Ne pas ramasser quoi que ce soit qui br le ou qui fume comme des cigarettes allumettes ou cendres chaudes...

Страница 11: ...connecter cette fiche une prise p les comme le montre la Figure 2 si une prise correctement mise la terre n est pas disponible Il faut utiliser l adaptateur temporaire uniquement jusqu au moment o un...

Страница 12: ...tion 5 C est l que le tuyau flexible d aspiration est fix la machine Loquet 6 Ouvrir les loquets pour acc der au compartiment inf rieur qui contient les moteurs et l l ment chauffant Opercule du drain...

Страница 13: ...eindre la temp rature de fonctionnement 6 Mettre la pompe en marche Mettre l aspiration en marche NOTE La pompe dispose d un pressostat int gr elle ne fonctionne que lorsque vous vaporisez 7 Commencer...

Страница 14: ...mpl tement ferm ou les joints d tanch it sont endommag s Le tuyau flexible int rieur d aspiration est fendu Le couvercle du r servoir de r cup ration n est pas ferm est fendu ou le joint d tanch it es...

Страница 15: ...425 322 0133 800 257 7982 FAX 425 322 0136 11015 47th Ave W Mukilteo WA 98275 VISIT US AT http www usproducts com...

Отзывы: