PREPARE PLUMBING

The water valve uses a standard 1/4" (6.35 mm) 
compression fitting. U-Line recommends using accessory 
water hook up kit – part # WATERHOOKUP. The kit 
includes a 10' (3 m) braided flexible water supply line and 
a brass hose fitting. When using a 1/4" (6.35 mm) O.D. 
soft copper supply line use the brass nut and sleeve 
included with the unit.

WARNING

!

Prior to installation, determine if this product 
contains a gravity style drain or factory installed 
drain pump. Products without a drain pump may 
only use a gravity style drain. Failure to connect 
water supply or drain line connections properly 
may result in water leakage, personal injury, 
and/or property damage. Disconnect power and 
turn off water to the unit before attempting to 
alter these connections. These connections are 
the responsibility of the owner and must be 
connected per local plumbing code. If you are 
uncertain of how to safely and properly install 
this product, contact a licensed plumber. 

Water Supply Connection

WARNING

!

Connect to potable water supply only.

CAUTION

!

Review, obey, and understand the local 
plumbing codes before you install your unit. 
Connect to the cold water supply. The water 
pressure should be between 20 and 120 psi (138 
and 827 kPa). The water line MUST have a shut-
off valve on the supply line.

CAUTION

!

Do not use any plastic water supply line. The line 
is under pressure at all times. Plastic may crack 
or rupture with age and cause damage to your 
home.

Do not use tape or joint compound when 
attaching a braided flexible water supply line 
that includes a rubber gasket. The gasket 
provides an adequate seal – other materials 
could cause blockage of the valve.

Failure to follow recommendations and 
instructions may result in damage and/or harm, 
flooding or void the product warranty.

CAUTION

!

Turn off water supply and disconnect electrical 
supply to unit prior to installation.

Use caution when handling back panel. The 
edges could be sharp.

1. Turn off water supply and disconnect electrical supply 

to product prior to attempting installation.

2. Remove the grille/access panel in the front and the 

back panel.

Содержание U-CLR1215S-40B

Страница 1: ...QUICK START GUIDE 1000 Series CLR1215 115 V 60 Hz...

Страница 2: ...to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all availab...

Страница 3: ...1 Model List 2 Safety and Warning 2 Environmental Requirements 3 Electrical 3 Water Hookup 7 Drain 8 Door Swing 9 General Installation 9 Integrated Panel Installation 11 Control Operation 11 First Us...

Страница 4: ...view detailed User Guides for all U Line products Clear Ice U CLR1215S 00B U CLR1215S 40B U CLR1215INT 00B U CLR1215INT 40B U CLR1215B 00B U CLR1215B 40B U CLR1215W 00B U CLR1215W 40B Outdoor Series U...

Страница 5: ...igned to operate between 50 F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best perform...

Страница 6: ...ces and is not recommended for your unit because it could be prone to nuisance tripping However be sure to consult your local codes Water Hookup INDOOR MODELS PREPARE PLUMBING Please use the braided s...

Страница 7: ...r harm flooding or void the product warranty CAUTION Turn off water supply and disconnect electrical supply to unit prior to installation 1 Turn off water supply and disconnect electrical supply to pr...

Страница 8: ...s product contact a licensed plumber Water Supply Connection WARNING Connect to potable water supply only CAUTION Review obey and understand the local plumbing codes before you install your unit Conne...

Страница 9: ...Normal operation creates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line 4 On the back panel break...

Страница 10: ...be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened during shipment Verify all co...

Страница 11: ...or Swing Units have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle...

Страница 12: ...cord 2 Gently push the unit into position Be careful not to entangle the cord or water and drain lines 3 Re check the leveling from front to back and side to side Make any necessary adjustments The u...

Страница 13: ...ct depth in order to avoid splits in the wood when hardwood is installed 11 Locate 6 of the 6x 1 1 4 32 mm screws provided with your unit 12 Using a Phillips screwdriver place one screw into each of t...

Страница 14: ...on to stabilize for 24 hours before rechecking ice thickness Ice is produced in layers resulting in a clear cube Ice in bin may develop surface frost which disappears when cube is placed in liquid Ice...

Страница 15: ...ur clear ice machine is pre set to produce ice between the optimal dimensions illustrated below Ice thickness adjustments are made using the control panel as follows 1 To enter the thickness adjustmen...

Страница 16: ...nty period two years on Modular 3000 Series for all U Line products U Line shall 1 repair any product or replace any part of a product and 2 for all Marine RV and Domestic U Line products sold and ser...

Страница 17: ...y come into contact with rain by virtue of outdoor use Exposure to other sources of water shall also cause this warranty to be void including flooding of the area in proximity of the unit greater than...

Отзывы: