The ice cube thickness is factory set for best overall 
performance. The factory setting is designed to maintain 
an ice bridge of approximately 1/16" to 1/8" (1.6 mm to 
3.2 mm) under normal conditions, resulting in a dimple of 
approximately 1/4" to 1/2" (6.4 mm to 12.7 mm) in 
depth. A fuller cube with less of a dimple results in a 
thicker ice bridge. As the ice bridge becomes thicker, the 
tendency for the cubes to stay together as a slab 
increases. A bridge thicker than 1/8" (3.2 mm) may cause 
cubes to overfill the ice bucket.

32 ice cubes are formed on a 4 x 8 slab during each cycle. 
Each cycle takes approximately 15-20 minutes at the 
default cube thickness (0).

Your clear ice machine is pre-set to produce ice between 
the optimal dimensions illustrated below:

Ice thickness adjustments are made using the control 
panel as follows:

1. To enter the thickness adjustment mode:

• Press and hold   for 5 seconds.

• The display will switch to “0” to confirm the 

thickness adjustment mode has been selected.

The factory setting is “0,” and the total range of 
adjustment is -5 to +5 (ideal range is -1 to +1). Use   to 
raise the setting and thicken the ice bridge, or   to lower 
the setting to thin the ice bridge.

Ice cubes in any given batch will vary, so it is necessary 
to choose cubes from the sample area for comparison 
when making adjustments.

DIMPLES

ICE BRIDGE

7/8"

(22 mm)

7/8"

(22 mm)

THINNER BRIDGE

THICKER BRIDGE

DEEPER DIMPLE

SHALLOWER DIMPLE

1/4" TO 1/2"

(6.4 mm to 12.7 mm)

DIMPLE 

1/16" TO 1/8"

(1.6 mm to 3.2 mm)

ICE BRIDGE

Cube Details

Factory Default Setting - 0

-5

SETTING

+5

SETTING

Содержание U-CLR1215S-40B

Страница 1: ...QUICK START GUIDE 1000 Series CLR1215 115 V 60 Hz...

Страница 2: ...to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all availab...

Страница 3: ...1 Model List 2 Safety and Warning 2 Environmental Requirements 3 Electrical 3 Water Hookup 7 Drain 8 Door Swing 9 General Installation 9 Integrated Panel Installation 11 Control Operation 11 First Us...

Страница 4: ...view detailed User Guides for all U Line products Clear Ice U CLR1215S 00B U CLR1215S 40B U CLR1215INT 00B U CLR1215INT 40B U CLR1215B 00B U CLR1215B 40B U CLR1215W 00B U CLR1215W 40B Outdoor Series U...

Страница 5: ...igned to operate between 50 F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best perform...

Страница 6: ...ces and is not recommended for your unit because it could be prone to nuisance tripping However be sure to consult your local codes Water Hookup INDOOR MODELS PREPARE PLUMBING Please use the braided s...

Страница 7: ...r harm flooding or void the product warranty CAUTION Turn off water supply and disconnect electrical supply to unit prior to installation 1 Turn off water supply and disconnect electrical supply to pr...

Страница 8: ...s product contact a licensed plumber Water Supply Connection WARNING Connect to potable water supply only CAUTION Review obey and understand the local plumbing codes before you install your unit Conne...

Страница 9: ...Normal operation creates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line 4 On the back panel break...

Страница 10: ...be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened during shipment Verify all co...

Страница 11: ...or Swing Units have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle...

Страница 12: ...cord 2 Gently push the unit into position Be careful not to entangle the cord or water and drain lines 3 Re check the leveling from front to back and side to side Make any necessary adjustments The u...

Страница 13: ...ct depth in order to avoid splits in the wood when hardwood is installed 11 Locate 6 of the 6x 1 1 4 32 mm screws provided with your unit 12 Using a Phillips screwdriver place one screw into each of t...

Страница 14: ...on to stabilize for 24 hours before rechecking ice thickness Ice is produced in layers resulting in a clear cube Ice in bin may develop surface frost which disappears when cube is placed in liquid Ice...

Страница 15: ...ur clear ice machine is pre set to produce ice between the optimal dimensions illustrated below Ice thickness adjustments are made using the control panel as follows 1 To enter the thickness adjustmen...

Страница 16: ...nty period two years on Modular 3000 Series for all U Line products U Line shall 1 repair any product or replace any part of a product and 2 for all Marine RV and Domestic U Line products sold and ser...

Страница 17: ...y come into contact with rain by virtue of outdoor use Exposure to other sources of water shall also cause this warranty to be void including flooding of the area in proximity of the unit greater than...

Отзывы: