PAGE 5 OF 16
0421 IH-2549
ROUTINE MAINTENANCE
DAILY
1.
Check Dust Bag
– Before each use, check the dust
bag and empty if nearly full.
2.
Belt Condition
– Check the belt for signs of wear.
Change the belt when it is loose or has cuts or
cracks. Refer to the diagram on the underside of the
base for proper installation of belt and brushroll.
3.
Supply Cord and Plug
– Check supply cord and
plug for any cuts or damage. If damaged, have
the supply cord and plug assembly replaced by a
qualified Sanitaire repair center.
4.
Motor
– If there are unusual sounds or if poor
performance occurs, the motor should be inspected
immediately by a qualified Sanitaire repair center.
WEEKLY
1.
Cloth Dust Bag
– Inspect the dust bag assembly for
any unusual wear. Replace bent clips, stretched
springs or a worn bag with genuine Sanitaire
replacement parts.
2.
Brushroll Bristle Strips –
Check the bristles for wear
once a week. The bristle strips should be replaced
when the bristles are less than 1/4 inch in length.
3.
Brush Roll Condition
– Check for and remove any
loose material, such as string or hair wrapped
around the brushroll.
MONTHLY
1.
Cleaning
– Inspect and clean the vacuum,
including the fan chamber and under the hood.
2.
Electrical
– Inspect the cord assembly for wear and
check for proper handle assembly.
3.
Handle
– Check the handle assembly for tightness
and replace handle bolts if missing.
4.
Motor
– A qualified Sanitaire repair center should
make a routine check of the motor every 6 months.
Inspect the motor immediately if there are any
unusual sounds or if poor performance occurs.
OPERATING ISSUE
RECOMMENDATIONS
Belts continue to break.
1. The agitator bar should be positioned so the belt
lines up with the grooves on the bottom frame of the
vacuum.
If there is little or no suction.
1. Inspect brush roller and opening under vacuum for
clogs and debris and clear if necessary.
Vacuum turns off while in use.
1. The machine may turn off due to overheating.
2. Check to make sure nothing is caught on the brush
roll and check for clogs.
Vacuum has a burning smell.
1. The belt may be damaged or something may be
caught in the brush roll.
2. Check brush roll for obstruction.
3. Replace belt.
TROUBLESHOOTING