background image

PAGE 5 OF 6 

1018 IH-7357

LCD DISPLAY

READING THE DISPLAY 

READY 

Jump starter is ready for use.

CONNECT   Clamps are disconnected or there is no or 

very low battery voltage detected.

COOLING   Internal battery temperature is too warm, 

cooling process begins.

OVERRIDE   Override mode has been engaged and 

clamps are live. Protections are removed.

LOW 

 Battery or alternator voltage is low and 

needs to be recharged.

CHARGE   Unit is charging or battery or alternator 

being tested is bad.

FULL 

Battery or alternator being tested is good.

0000%

 

 Displays level of internal battery or displays 

level of vehicle battery charge in test mode.

0000

 V 

 Displays voltage level of vehicle electrical 

system in test mode.

FAULT/ERROR CODES

Over-Discharged Battery Protection –  

Fault/Error Code: 

F01

•  During the normal operation of this unit, if the 

voltage drops below a safe point, the error code 

F01

 will display.

•  Plug jump starter into a charging source and 

recharge the internal battery.

Low Temperature Protection – Fault/Error Code: 

F02

 

•  When the core temperature on the surface of the 

battery drops below 32°F, the unit stops working. The 

error code 

F02

 will display.

•  Bring jump starter indoors and allow it to warm at 

room temperature. Once battery temperature is 

above 32°F unit will operate again.

Overheat Protection – Fault/Error Code: 

F03

 

•  When the temperature on the surface of the battery 

exceeds 131°F, the unit will stop working to prevent 

damage to the internal battery.

•  The error code 

F03

 will display and flash until the 

unit is cool enough to use again.

•  The unit should not operate or be subjected to 

temperatures at or above 518°F.

Overload Protection – Fault/Error Code: 

F04

•  If a user attempts to start a vehicle’s engine whose 

cranking current is higher than the rated current of 

the jump starter, the unit will stop cranking and an 

error code 

F04

 will display.

•  The unit will enter into COOLING mode and a 

second attempt can be made once cooled.

Reverse Polarity – Fault/Error Code: 

F05

•  Once the engine start button is pressed, the unit will 

shut down and the error code 

F05

 will display. This 

occurs if the unit senses that the clamps are not 

connected positive (+) to positive battery post and 

negative (–) to negative battery post.

•  Recheck connections and connect correctly.

WARNING! This protection is disabled when 
using Override Mode.

Short Circuit Protection – Fault/Error Code: 

F06

•  Once the engine start button is pressed, the unit will 

shut down and the error code 

F06

 will display if the 

clamps are short circuited, connected to each other 

or there is a dead short.

•  Recheck connections and connect correctly.

WARNING! This protection is disabled when 
using Override Mode.

v

/

READY

LOW CHARGE

CHARGE

CONNECT

OVERRIDE

COOLING

ERROR CODE

MEANING

F01

Recharge unit

F02

Battery temperature is low

F03

Battery temperature is high

F04

Current overload

F05

Clamps reversed

F06

No battery found

Содержание RESCUE H-7357

Страница 1: ...ent to start cars light trucks ATVs boats lawn and garden equipment and other 12V equipment Units feature a 5V USB Unit also features a safety work light that can be set to continuous on or flashing mode LCD display screen provides indication of reserve power level and shows when unit is charged or fully charged Each LCD display will also prompt an error protection code if the unit is incorrectly ...

Страница 2: ... intended for use by young people without supervision Do not set the unit on flammable materials such as carpeting upholstery paper cardboard etc Never place the unit directly above battery being jumped WARNING Working in the vicinity of a lead acid battery is dangerous Batteries generate explosive gases during normal battery operation It is important to follow these instructions each time you use...

Страница 3: ...tton for three seconds to switch on the device Press the power button for three seconds to switch off the device USING LED LIGHT Activate power button on the jump starter The light works in the following sequence by pressing the switch Press light button once flashing white light Press light button twice steady white light Press light button third time turns off light USING USB PORTS The two USB p...

Страница 4: ...t to start the vehicle during Ready cycle NOTE If the LCD display does not show READY and instead shows CONNECTING the battery voltage being detected as less than two volts If this occurs see Override Mode instructions Starting the engine engaging the ignition activates a 10 second start cycle countdown After each starting attempt the unit will cool down for 30 seconds LCD will display the remaini...

Страница 5: ...ture on the surface of the battery exceeds 131 F the unit will stop working to prevent damage to the internal battery The error code F03 will display and flash until the unit is cool enough to use again The unit should not operate or be subjected to temperatures at or above 518 F Overload Protection Fault Error Code F04 If a user attempts to start a vehicle s engine whose cranking current is highe...

Страница 6: ...t car Clamps are not making a good connection to the battery The unit is not charged The vehicle s battery voltage is over 15V The vehicle does not have a battery The temperature of the jump starter s internal battery is low Check for poor connection to battery Make sure connection points are clean Check the battery charge status and recharge unit if necessary You cannot use this jump starter for ...