background image

USER GUIDE

Water Hookup 1

u-line.com

SAFETY •

INSTALLATION & INTEGRATION

 • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

Water Hookup

PREPARE PLUMBING

The water valve in this unit uses a standard 1/4" 
(6.35 mm) compression fitting. U-Line recommends a 
braided stainless steel water supply line.
P/N (WATERHOOKUP).

CAUTION

!

Plumbing installation must observe all state and 
local codes. All water and drain connections 
MUST BE made by a licensed/qualified plumbing 
contractor. Failure to follow recommendations 
and instructions may result in damage and/or 
harm.

Water Supply Connection

When connecting the water supply, please note the 
following:

• Before installing the unit and connecting to the cold 

water supply, review the local plumbing codes.

• The water pressure should be between 20 and 120 psi 

(138 and 827 kPa).

• The water line MUST have a shut-off valve in the 

supply line.

• The water line should be looped into 2 coils. This will 

allow the unit to be removed for cleaning and servicing. 
Make certain that the tubing is not pinched or damaged 
during installation.

WARNING

!

Connect to potable water supply only.

CAUTION

!

Do not use any plastic water supply line. The line 
is under pressure at all times. Plastic may crack 
or rupture with age and cause damage to your 
home.

Do not use Teflon tape or joint compound on the 
water fitting. The rubber washer provides an 
adequate seal. Other materials could cause 
blockage of the valve.

Failure to follow recommendations and 
instructions may result in damage and/or harm, 
flooding or void the product warranty.

Use new hose set. Do not reuse old hose set.

CAUTION

!

Turn off water supply and disconnect electrical 
supply to unit prior to installation.

Use caution when handling back panel. The 
edges could be sharp.

1. Turn off water supply and disconnect electrical supply 

to product prior to attempting installation.

2. Remove the grille/access panel in the front and the 

back panel.

 
 
 
 
 
 

Содержание Origins BI-98

Страница 1: ...USER GUIDE SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE ADA Height Compliant Series BI98 15 Crescent Ice Maker RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Страница 2: ...l Requirements Electrical Cutout Dimensions Product Dimensions Water Hookup General Installation Integrated Panel Dimensions Integrated Panel Installation Grille Plinth Installation Door Swing Door Ad...

Страница 3: ...ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all ava...

Страница 4: ...sted throughout this guide SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger Warning or Caution based on the risk type DANGER Danger means that failure to follow th...

Страница 5: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulati...

Страница 6: ...C or higher may reduce the unit s ability to reach low temperatures For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity a...

Страница 7: ...use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded...

Страница 8: ...e is required for an electrical and water connection in the rear NOTICE Units can NOT be installed behind a closed cabinet door CUT OUT DIMENSIONS NOTICE It is extremely important that this unit sits...

Страница 9: ...uct Dimensions 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 27 3 8 695 mm 14 15 16 379 mm 20 508 mm Add 1 1 2 For For Water Line Clearance...

Страница 10: ...pply line The water line should be looped into 2 coils This will allow the unit to be removed for cleaning and servicing Make certain that the tubing is not pinched or damaged during installation WARN...

Страница 11: ...components other than the solenoid valve Normal operation creates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or dama...

Страница 12: ...not level the ice mold will not fill evenly Use a level to confirm the unit is level Level should be placed along top edge and side edge as shown INSTALLATION 1 Plug in the power electrical cord 2 Ge...

Страница 13: ...door panels can be flat or raised as long as the maximum panel thickness where inserted into the door reveal channel is no more than 1 4 6 mm thick For raised panels the depth of the reveal is 1 4 6 m...

Страница 14: ...Pull door gasket out of groove top edge of door only Start in the middle and pull outward moving toward the edge This may take some force 3 Remove top screw on each side securing door handle Slightly...

Страница 15: ...nnect electric power to the unit before removing the grille WARNING DO NOT touch the condenser fins 4 The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to t...

Страница 16: ...TION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Door Swing All units have a zero clearance for the door to open 90 U Line recommends a minimum door clearance of 1 4 6 mm to accommodate the handle if t...

Страница 17: ...of the door ALIGNMENT AND ADJUSTMENT 1 Loosen do not remove top and bottom hinge screws 2 Align door squarely with cabinet Make sure gasket is firmly in contact with cabinet all the way around the do...

Страница 18: ...on the opposite side of the door Do not place handle on door until you have completed step 9 9 Remove plastic hole plug from door handle and relocate to opposite side Lift the handle slightly and pre...

Страница 19: ...assembly 13 Place the door latch assembly on opposite side of unit Be sure to tighten all three screws securely 14 Place door on lower hinge pin Invert and install upper hinge on door Fasten upper hin...

Страница 20: ...at the factory Initial startup requires no adjustments NOTICE U Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may d...

Страница 21: ...rtain sounds are normal during the unit s operation You may hear the compressor or fan motor the water valve or ice dropping into the ice bucket CAUTION NEVER use an ice pick knife or other sharp inst...

Страница 22: ...igns on the control box CAUTION Too large of an adjustment to the screw can cause the water to overflow the ice maker and can cause property damage 3 Turn the adjusting screw toward the minus sign clo...

Страница 23: ...GRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or...

Страница 24: ...eaners or polishes on any glass surfaces Clean any glass surfaces with a non chlorine glass cleaner Do not use cleaners not specifically intended for stainless steel on stainless surfaces this include...

Страница 25: ...ower to the unit 2 Remove ice bucket and discard ice 3 Place towel or other absorbent material on bottom of ice bin 4 Fill the ice bucket half full with warm not hot water This will help the unit defr...

Страница 26: ...ntal conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the condenser fins The condenser fins a...

Страница 27: ...ter is removed from the lines 7 The door must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be...

Страница 28: ...1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Accessories 80 51004 00 Accessories Anti Tip Mounting Brackets US 18 99 WATERHOOKUP Accessories Braided Water Li...

Страница 29: ...dency to reflect normal appliance operating noises Listed below are common refrigeration components with a brief description of the normal operating sounds they make NOTE Your product may not contain...

Страница 30: ...erature setting Ambient temperature where installed Installation in direct sunlight or near a heat source The number of door openings and the time the door is open The time the internal light is illum...

Страница 31: ...ervice com 3 The warranty listed above does not apply to floor display models The warranty for these models shall be 30 days from the date of retail purchase and only if U Line s Product Registration...

Страница 32: ...IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ALL OF WHICH ARE DISCLAIMED U Li...

Отзывы: