PAGE 8 OF 69
1021 IH-9554
MENU SETTINGS
The User Menu allows the customizing of balance
settings.
NOTE: Additional sub-menus may be available
if Interface Options are installed. See Interface
User Manual for the additional setting
information.
MENU:
C.A.L
S.E.t.U.P
r.E.A.d
U.n.i.t
Menu
Items:
Zero2
1
Span1
Span2
1
Lin1
Lin2
1
GEO
End
Reset
D.Scale
Cap2
1
Grad2
1
Pwr. Un
Zero
A.Opt
A.Tare
Bp.Opt
Bp.Sig
Bp.Key
Accum
End
Reset
Stable
Filter
AZT
Light
A.Off
End
Reset
kg
g
lb
oz
lb:oz
End
1
Only visible when dual scale is set to On. Some units
may not be available in all models.
MENU:
P.r.i.n.t.1
C.O.M.1
L.O.C.k
E.n.d
Menu
Items:
Reset
Stable
A.Print
Contnt
Layout
Data.Tr
End
Reset
Baud
Parity
Stop
Handsh
Alt.Cm
End
L.Setup
L.Read
L.Unit
L.Print
L.COM
End
NOTE: When Legal For Trade is set to on
(LFT switch in locked position), the menu
settings are affected as follows:
• Calibration (
C.A.L
) menu is not accessible.
• Dual Scale, Capacity 2, Graduation 2, Filter
and Units are locked at their current settings.
Zero Range setting is locked at 2%.
• Stable Range setting is locked at 1d.
• Auto-Zero Tracking setting is locked at 0.5d.
• Stable Only is locked On.
• Auto Print/Continuous is disabled.
• Lb:oz is locked Off.
Summary of button navigation functions in menu mode:
• Yes: Allows entry into the displayed menu.
o
Accepts the displayed setting and advances to
the next item.
• No: Skips by the displayed menu.
o
Rejects the displayed setting or menu item and
advances to the next available item.
• Back: Moves backward through the upper and
middle level menus.
o
Backs out of a list of selectable items to the
previous middle level menu.
• Exit: Exits from menu directly to the active weighing
mode.
CALIBRATION MENU
Enter this menu to perform calibrations.
When the scale is operated for the first time, a span
calibration is recommended to ensure accurate
weighing results. Before performing the calibration, be
sure to have the appropriate calibration weights as
listed in table. Ensure that the LFT switch/calibration lock
is set to unlocked position (See Figure 6 on page 16) or
adjust the GEO setting according to user's location.
PROCEDURE
Press and hold Menu until [
mMeNU
] is displayed. When
the button is released, the display will show [
C.A.L
]. Press
Yes to accept. [
SpaN
] will then be shown. Press Yes to
begin the span calibration. [
0 kg
] will be displayed.
Press Yes to accept. [
--C--
] will be displayed while zero
reading is stored. Next, the display shows the calibration
weight value. Place the specified calibration mass on
the pan. Press Yes to accept the weight or No to select
an alternate weight. [
--C--
] will be displayed while the
reading is stored. The display will show [
done
] if the
calibration was successful. The scale returns to the
previous application mode and is ready for use.
REQUIRED SPAN CALIBRATION MASS (SOLD SEPARATELY)
CAPACITY
MASS
CAPACITY
MASS
1500g
1.5kg / 3lb
15000g
15kg / 30lb
3000g
3kg / 6lb
30000g
30kg / 60lb
6000g
6kg / 15lb
NOTE: When active unit is g or kg, the
calibrating unit will be in kg. When active unit
is lb, oz or lb:oz, the calibrating unit will be in lb.
For linearity calibration, the calibration mass is
fixed. Mid-point is always half of full capacity.