background image

PAGE 3 OF 9 

0621 IH-7272

INSTALLATION CONTINUED

7.  Place screws (provided) in holes on the canopy. 

8.  Route exit input wires through knockout in exit frame, 

pipe nut and metal mounting plate. 

9.  Make wiring connection. For 120V, use black and 

white wires; for 277V, use red and white wires. 

WARNING! Properly insulate the unused lead 
with a wire nut (provided) or other approved means. 

10.  Push wire connections into junction box. Secure 

mounting plate to junction box (hardware not included).

11.  Secure canopy to steel mounting plate with screws 

installed in step seven. 

12.  Place pipe nipple through mounting 

hole of frame until gasket touches 

frame. Thread a second nut onto 

pipe nipple on the inside of frame to 

lock canopy into place. (See Figure 9) 

Once canopy is locked, there will 

not be any side-to-side movement.

13.  Remove proper chevron(s) as required. When 

removing chevrons, it may be helpful to remove 

diffuser to allow easier access to chevrons. 

NOTE: Remember to reinstall the diffuser once 

chevron(s) have been removed. 

14. Connect battery to lamp board.

15.  Secure faceplate(s) to frame 

with screws. (See Figure 10)

NOTE: Push center of 

lens to balance when 
tightening screws. 

16.  Press to make sure unit is 

locked onto the wall tightly.  

Distance between bracket 

and wall should be less than 

2 mm. (See Figures 11-12)

17.  Apply continuous AC 

power and press test 

button to check operation.

Figure 12

Push

MAINTENANCE

OPERATION

BATTERY BACKUP

1.  Apply AC power to the unit. The LED indicator will be red. 

2.  After the battery has been left to charge for two 

hours, test the unit by pushing the switch. The LED 

indicator turns off and the LED board stays on. 

3.  When the switch is released, the LED indicator turns 

back to red and the LED board stays on.

CAUTION! Always turn off AC power to the equipment before servicing. Servicing should be performed 
only by a qualified service technician. Only use manufacturer supplied replacement parts. 

BATTERY

Figure 9

Figure 10

Figure 11

The battery supplied with this model requires no 

maintenance. However, it should be tested periodically 

and replaced when it no longer operates the connected 

sign for the duration of a 30-second or 90-minute test. 

The supplied battery has a life expectancy of five years 

when used in a normal ambient temperature of 72ºF. 

NPFA 101 (Life Safety Code) requires that all emergency 

lighting equipment be functionally tested every 30 days 

for a minimum of 30 seconds, and tested annually for 

a full 90-minute duration. Written records of the testing 

are to be kept for examination by the authority having 

jurisdiction.

1-800-295-5510

uline.com

Содержание H-7272

Страница 1: ...aintained in accordance with the applicable installation codes by a person familiar with the operation of the product and the hazards involved This product must be installed in accordance with applica...

Страница 2: ...kplate for supply wire leads 5 Remove backing from self adhesive junction box gasket and adhere to backplate 6 Route input wires through center holes of backplate and make wiring connection For 120V u...

Страница 3: ...ocked onto the wall tightly Distance between bracket and wall should be less than 2 mm See Figures 11 12 17 Apply continuous AC power and press test button to check operation Figure 12 Push MAINTENANC...

Страница 4: ...ebe instalarse y recibir mantenimientos de acuerdo a los c digos de instalaci n aplicables por alguien familiarizado con el funcionamiento del producto y los peligros que conlleva Este producto debe i...

Страница 5: ...es de suministro 5 Retire el respaldo de la junta autoadhesiva de la caja de conexiones y adhi rala a la placa posterior 6 Gu e los cables de entrada a trav s de los orificios de la placa posterior y...

Страница 6: ...d est bien asegurada a la pared La distancia entre el soporte y la pared deber a ser de menos de 2 mm Vea Diagramas 11 12 17 Aplique electricidad CA continua y presione el bot n de test para verificar...

Страница 7: ...ions d installation et d entretien L entretien de cet quipement doit tre effectu uniquement par un personnel de maintenance qualifi Cet quipement doit tre install et entretenu conform ment aux codes d...

Страница 8: ...de la plaque arri re pour les fils conducteurs 5 Retirez la doublure du joint du bo tier de jonction puis collez le joint la plaque arri re 6 Acheminez les fils d entr e travers les trous au centre d...

Страница 9: ...l unit pour vous assurer qu elle est bien s curis e au mur La distance entre le support et le mur doit tre moins de 2 mm Voir Figures 11 et 12 17 Fournissez une alimentation CA continue et appuyez su...

Отзывы: