background image

PAGE 4 OF 6 

1114 IH-4729

AVERAGE PIECE WEIGHT (APW)

When the 

MODE

 button 

is released, CLr.PW Pcs is 

displayed.

NOTE: If no APW has been previously stored, 
the CLr.PW display is skipped and the display 
shows PUt 10 Pcs.

CLEARING A STORED APW

Press the 

YES

 button to clear the stored APW.

RECALLING A STORED APW

1.  Press the 

NO

 button to  

recall the existing APW.

2.  Press the 

FUNCTION MODE

 

button to temporarily 

display the APW value.

ESTABLISHING THE AVERAGE PIECE WEIGHT (APW)

The display shows PUt 10 Pcs.

ESTABLISHING A NEW APW

1.  Press the 

NO

 button to 

increment the sample size. 

Choices are 5, 10, 20, 50, 

100 and 200.

2.  To establish the APW, 

place the specified 

quantity of samples on  

the scale and press the  

YES

 button to capture  

the weight.

BEGIN COUNTING

1.  Place the parts on the 

scale and read the count. 

If a container is used, be 

sure to tare the empty 

container first.

LEGAL FOR TRADE

When the Indicator is used in trade or a legally 

controlled application, it must be set up, verified and 

sealed in accordance with local weights and measures 

regulations. It is the responsibility of the purchaser to 

ensure that all pertinent legal requirements are met.

SETTINGS

Before verification and sealing, perform the following steps:

1.  Verify that the menu settings meet the local weights 

and measures regulations.

2.  Perform a calibration.
3.  Set Legal for Trade to ON in the Setup menu.

4.  Exit the menu.

5.  Disconnect power from the indicator and open the 

housing. 

6.  Set the security switch to the ON position. 

7.  Close the housing.

8.  Reconnect power and turn the indicator on.

NOTE: For installations that employ the audit 
trail sealing method, steps 5 to 8 are not 
required. However, the security switch may be 
set to ON to safeguard against unintentional 

changes to configuration and calibration 
settings.

NOTE: When Legal for Trade is set to ON and the 
security switch is set to ON, the following menu 
settings cannot be changed: Span Calibration, 
Linearity Calibration, GEO, LFT, Calibration 
Unit, Capacity, Graduation, Power On Unit, Zero 
Range, Auto Zero Tracking, Expanded Mode, 

Count Mode, Kilogram Unit, Pound Unit, Gram 
Unit, Ounce Unit, Pound Ounce Unit, Stable 
Only. To enable editing of these menu settings, 

return the security switch to the OFF position 

and set LFT menu item to OFF.

VERIFICATION

The local weights and measures official or authorized 

service agent must perform the verification procedure. 

Please contact your local weights and measures office 

for further details.

OPERATION CONTINUED

Отзывы: