4.  When eyes are in the stream of fluid, use thumb 

and forefinger of each hand to open eyelids. Hold 

eyelids open until thoroughly flushed. 15 minutes is 

recommended.

5.

  After flushing, seek medical attention immediately.

6.  Safety and supervision personnel must be notified 

when the unit has been used and must be refilled.

OPERATION CONTINUED

INSPECTION AND MAINTENANCE

SAFETY PRECAUTIONS

1.  When filled with flushing fluid, the Porta Stream II 

weighs approximately 150 lbs. Provide the necessary 

equipment or personnel to install or remove the filled 

Porta Stream II from the mounting bracket.

2.  Install the mounting bracket so the Porta Stream II is 

level.

3.  Read all warning notices on the saline concentrate 

bottle before mixing.

4.  Wear suitable eye protection and gloves when 

mixing the concentrate.

5.  Do not add any product or material to the solution 

of saline concentrate and water.

INSPECTION

An individual or department must be assigned the 

task of checking all self-contained eyewash units 

on a weekly schedule to ensure the unit is in proper 

operating condition with adequate levels of flushing 

fluid. Records of these weekly inspections should 

be kept with the unit. Eyewash units containing 

saline solution or water with an additive should be 

cleaned and refilled per the solution manufacturer's 

recommendations. Units containing just water need 

to be cleaned and refilled once a week. Use of a 

fluid beyond the expiration date may result in serious 

personal injury.

NOTE: The S-9876 Saline Concentrate contains 
a specially formulated salt compound. There 
may be a white residue if solution has dried on 
the Porta Stream II surfaces. The white residue 

can be removed by wiping with a damp cloth.

TO REPLACE FLUSHING FLUID IN EYEWASH STATION

1.  Place an empty container large enough to hold  

16 gallons of liquid under the Porta Stream II.

2.  Pull rubber strap from nozzles and allow unit to drain 

into empty container.

3.  Once there is no flow from nozzles, open fill cap on 

top of unit and turn upside down over container to 

empty any remaining fluid.

4.  Partially fill unit with clean tap water and agitate 

thoroughly. Turn upside down over container to 

empty fluid.

5.  Replace fill cap on top of unit. Partially fill unit 

with clean tap water again, allowing fluid to drain 

through eyewash nozzles.

NOTE: If nozzles are blocked, they may 
be opened by inserting a pin to remove 

obstructions. If obstructions cannot be 

removed, contact Uline Customer Service 

at 1-800-295-5510 for replacement nozzles 
(H-1142-NOZ).

6.  Open fill cap on top of unit and turn upside down 

over container to empty any remaining fluid.

7.  For best results, disinfect unit each time fluid is 

changed.

8.  Reassemble unit and fill per instructions under "Filling 

the Eyewash Station" on page 2.

π

 CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA

1-800-295-5510

uline.com

Содержание H-1142

Страница 1: ...le s no less than 33 and no greater than 53 from the floor and 6 minimum from the wall or nearest obstruction 2 Eyewash units shall be in accessible locations that require no more than 10 seconds to r...

Страница 2: ...strap are clean and dry and that the strap is fully seated on the nozzles 7 Pour the mixed solution into the unit 8 If your eyewash station is equipped with a separate vent cap replace the vent cap Cl...

Страница 3: ...ions Units containing just water need to be cleaned and refilled once a week Use of a fluid beyond the expiration date may result in serious personal injury NOTE The S 9876 Saline Concentrate contains...

Страница 4: ...1 La unidad Porta Stream II se posicione con la boquilla a no menos de 83 8 cm 33 y no m s de 134 6 cm 53 del suelo y a un m nimo de 15 2 cm 6 de la pared o la obstrucci n m s cercana 2 Las unidades...

Страница 5: ...mpias y secas y de que la correa est completamente asentada sobre las boquillas 7 Vierta la soluci n mezclada en la unidad 8 Si su estaci n lavaojos est equipada con una tapa con ventilaci n independi...

Страница 6: ...vo deber n limpiarse y rellenarse siguiendo las recomendaciones del fabricante de la soluci n Las unidades que nicamente contengan agua necesitan limpiarse y rellenarse una vez a la semana El uso de u...

Страница 7: ...e plac e de fa on ce que la buse soit une distance minimale de 83 8 cm 33 po et maximale de 134 6 cm 53 po du sol et une distance minimale de 15 2 cm 6 po du mur ou de l obstacle le plus pr s 2 Les do...

Страница 8: ...ns de solution 6 Assurez vous que les buses et la courroie sont propres et s ches et que la courroie est fermement log e sur les buses 7 Versez la solution m lang e dans l unit 8 Si votre douche ocula...

Страница 9: ...t remplies selon les recommandations du fabricant de la solution Les unit s contenant de l eau seulement doivent tre nettoy es et remplies une fois par semaine L utilisation d un liquide p rim peut en...

Отзывы: