background image

PAGE 2 OF 9 

0719 IH-1142

UNIT LOCATION AND INSTALLATION CONTINUED

When installing the hanging bracket, the horizontal holes 

in the bracket must be 52½" to 72½" from the floor in 

order to have the nozzles positioned as required by  

ANSI Z358.1-2014. (See Figure 1)

After installing the hanging bracket, hang unit by 

placing the handle onto the bracket. Check the nozzle 

height. Place the emergency eyewash sign (if included 

with your model) in a visible area to mark the location of 

the unit.

FILLING THE EYEWASH STATION

MIXING INSTRUCTIONS

Saline concentrate (S-9876) is formulated to be mixed 

with potable drinking water, in a ratio of 

10 parts 

water to one part saline concentrate.

 To prepare the 

16 gallons of solution required to fill the Porta Stream 

II, you will need 14.5 gallons of water to mix with the 

180 ounces of saline concentrate. For best results, use 

filtered water. If filtered water is not available, use 

potable water. The solution may be mixed directly in 

the Porta Stream II unit. For best results, mix in an area 

which is clean and free of airborne particles. 

Do not 

add any product or material to the solution of saline 
concentrate and water.

NOTE: If using the wall bracket mount, remove 
the unit from the wall bracket before filling.

1.  Wear protective eyewear and gloves and follow 

sanitary practices during mixing.

2.  Use a clean container of sufficient capacity to mix 

16 gallons.

3.  Add approximately 5 gallons of filtered water to the 

container.

4.  Add 1/3 of the saline concentrate to the container 

and agitate or mix thoroughly.

5.  Repeat steps 3 and 4 adding sufficient water and 

saline concentrate to make a total of approximately 

16 gallons of solution.

6.  Ensure that the nozzles and pull strap are clean and 

dry and that the strap is fully seated on the nozzles.

7.  Pour the mixed solution into the unit.

8.  If your eyewash station is equipped with a separate 

vent cap, replace the vent cap. Close the fill cap 

and attach a security device or inspection tag if 

desired.

9.  Properly dispose of the saline concentrate bottle. Do 

not reuse.

10.  Solution must be replaced 6 months after mixing.

OPERATION

Employees must be instructed in the use of emergency 

eyewash stations. Studies have shown that obtaining 

emergency flushing within the first 10 seconds in eye 

emergencies is critical. It is required that training be 

provided to employees in each department where eye 

hazards exist. This training should be scheduled on a 

regular basis to keep both current and new employees 

aware of the location of all eyewash devices, as well as 

to reinforce the importance of obtaining immediate eye 

washing in emergencies.

1.  The sooner the injured person can flush his or her 

eyes, the less likely there will be of eye damage. 

Seconds can make the difference in preventing 

serious eye injury or blindness.

2.  All employees must be reminded this unit is for 

emergency use only. Tampering with this unit or 

using it for non-emergency purposes may cause 

the unit to not operate properly in an emergency 

situation.

In an emergency, the eyes may involuntarily clamp 

shut and the individual may be experiencing pain, 

anxiety and disorientation. They may need assistance 

from other workers in getting to and using the eyewash 

station.

1.  Start the fluid flow by grasping the pull strap and 

pulling the strap upward.

2.  When the fluid is flowing, place the injured person's 

left hand around the left nozzle and the right hand 

around the right nozzle.

3.  The injured person should then lower his or her head 

into the Porta Stream II toward their hands.

EMERGENCY

EYEWASH STATION

Figure 1

52½ - 72½" from floor

Metal Hanging 

Bracket

Содержание H-1142

Страница 1: ...le s no less than 33 and no greater than 53 from the floor and 6 minimum from the wall or nearest obstruction 2 Eyewash units shall be in accessible locations that require no more than 10 seconds to r...

Страница 2: ...strap are clean and dry and that the strap is fully seated on the nozzles 7 Pour the mixed solution into the unit 8 If your eyewash station is equipped with a separate vent cap replace the vent cap Cl...

Страница 3: ...ions Units containing just water need to be cleaned and refilled once a week Use of a fluid beyond the expiration date may result in serious personal injury NOTE The S 9876 Saline Concentrate contains...

Страница 4: ...1 La unidad Porta Stream II se posicione con la boquilla a no menos de 83 8 cm 33 y no m s de 134 6 cm 53 del suelo y a un m nimo de 15 2 cm 6 de la pared o la obstrucci n m s cercana 2 Las unidades...

Страница 5: ...mpias y secas y de que la correa est completamente asentada sobre las boquillas 7 Vierta la soluci n mezclada en la unidad 8 Si su estaci n lavaojos est equipada con una tapa con ventilaci n independi...

Страница 6: ...vo deber n limpiarse y rellenarse siguiendo las recomendaciones del fabricante de la soluci n Las unidades que nicamente contengan agua necesitan limpiarse y rellenarse una vez a la semana El uso de u...

Страница 7: ...e plac e de fa on ce que la buse soit une distance minimale de 83 8 cm 33 po et maximale de 134 6 cm 53 po du sol et une distance minimale de 15 2 cm 6 po du mur ou de l obstacle le plus pr s 2 Les do...

Страница 8: ...ns de solution 6 Assurez vous que les buses et la courroie sont propres et s ches et que la courroie est fermement log e sur les buses 7 Versez la solution m lang e dans l unit 8 Si votre douche ocula...

Страница 9: ...t remplies selon les recommandations du fabricant de la solution Les unit s contenant de l eau seulement doivent tre nettoy es et remplies une fois par semaine L utilisation d un liquide p rim peut en...

Отзывы: