3-6
Section 3 - Service and Repair
ICE MAKER OPERATING CYCLES
Freeze Cycle (
)
• Temperature control terminals 2 and 3 are closed.
• Power to the compressor.
• Power to the condenser fan.
Figure 7. Freeze Cycle\
Harvest-1 Cycle (
• Temperature control terminals 2 and 3 are open - 2 and 1 close.
• No power to the compressor or condenser fan.
• If bin arm is down, power goes through bin arm switch to the ice
maker motor. If bin arm is up, the ice maker will not harvest.
Figure 8. Harvest-1 Cycle (Hold Switch in Normal Position)
SWITCH
LIMIT
orange
black
black
black
MOTOR
MAKER
ICE
MOLD HEATER
WATER
SWITCH
FILL
C
NC
MOTOR
FAN
LOAD
OVER
black
RELAY
START
COMP.
SWITCH
OFF
ON
black
black
blue
black
CONTROL
TEMP.
NC
black
orange
3
yellow
2
orange
SWITCH
BIN
red
NO
1
C
NO
brown
black
white
C
SWITCH
HOLD
VALVE
WATER
ground
UL183-4
(Hold Switch In Normal Position)
SWITCH
LIMIT
orange
black
black
black
MOTOR
MAKER
ICE
MOLD HEATER
WATER
SWITCH
FILL
C
NC
MOTOR
FAN
LOAD
OVER
black
RELAY
START
COMP.
SWITCH
OFF
ON
black
black
blue
black
CONTROL
TEMP.
NC
black
orange
3
yellow
2
orange
SWITCH
BIN
red
NO
1
C
NO
brown
black
white
C
SWITCH
HOLD
VALVE
WATER
ground
UL183-5
Содержание BI95FCB
Страница 9: ...1 8 Section 1 General Information This page intentionally left blank...
Страница 27: ...3 12 Section 3 Service and Repair THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 29: ...4 2 Section 4 Parts U LINE ICE MAKER ASSEMBLY...
Страница 61: ...4 34 Section 4 Parts This page intentionally left blank...
Страница 63: ...5 2 Section 5 Wiring Diagrams U CO29A CO1175A BI2115 ADA15IM 115 VOLT ULN 29R 115 VOLT...
Страница 64: ...5 3 Section 5 Wiring Diagrams 1075BEV 1075WC 115 VOLT...
Страница 65: ...5 4 Section 5 Wiring Diagrams ULN 95 ULN 98 SP18 22 1095 220 VOLT CO 29A CO1175 BI2115 ADA15IM 220 VOLT...