USER GUIDE
Service Mode 3
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
To clear the error log use Down to select “Clear Errors”
and press Select to confirm.
To exit the Actual Temps menu use Up to select
“Return to Menu” and press Select to confirm.
RELAY STATUS
Relay status displays the current state of each relay. While
all available relays are displayed, only a portion are used.
NOTE: The Cond (Condenser Fan) will switch state with
the compressor relay, however the condenser fan is
actually powered through a DC output and is independent
of the Cond relay. Condenser fan status can be viewed
through the “Output” service menu option.
To access Relay Status
1. Use Down to select “Relay Status”.
2. Press Select .
3. Use Up and Down to scroll through available
information.
To exit the Relay Status simply press Select to exit.
RELAY TOGGLE
Relay toggle is used to manually switch the state of each
relay to test for proper operation. In addition to the AC
relays, DC outputs may also be toggled. Relay toggle can
also be used to force the unit into a particular state. For
example, to force a 3018 / 3045 into a cooling cycle
activate Comp, F1, and F3.
ID
Description
Status
Mull
Mullion Heater
Not Used
Cond
Condenser Fan
Used
Def
Defrost Valve
Not Used
LVLV
Left Valve
Not Used
RVLV
Right Valve
Not Used
Pan
Pan Heater
Not Used
Comp
Compressor
Used
WV
Water Valve
Used
Pump
Circulation Pump
Used
Harvest
Harvest
Used
Up
Select
Down
RETURN TO MENU
RELAY STATUS
MULL COND DEF LVLV
OFF OFF OFF OFF
ID
Description
Type
Cond
Fan
AC
LVLV
Left Valve (Not Used)
AC
RVLV
Right Valve (Not Used)
AC
Pan
Pan Heater (Not Used)
AC
Comp
Compressor
AC
F1
Evaporator Fan (Not Used)
DC
F2
Evaporator Fan (Not Used)
DC
F3
Condenser Fan (Not Used)
DC
L1
Cabinet Lighting
DC
L2
Cabinet Lighting (Not Used)
DC
WV
Water Valve
AC
Pump
Circulation Pump
AC
Harvest
Harvest
AC
Up
Select
Down
RETURN TO MENU
RELAY TOGGLE
MULL OFF
COND OFF