Control Operation - Service 5
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
Outputs
Outputs is used to monitor the state of DC outputs.
To access Outputs
1. Use Down to select “Outputs”.
2. Press Select .
3. Use Up and Down to scroll through available
information.
To exit the Input Status menu use Up to select “Return
to Menu” and press Select to confirm.
Offsets
NOTICE
Customer care MUST be notified and approve of any
changes to the differential before they are made. Failure to
notify customer care will void the warranty.
Offsets are used to adjust or correct thermistor readings.
Offset values are added to the current thermistor reading
and are then used by the control board to determine
cooling and defrost cycle times. Offsets have a range of
+/- 10°C. Corrected values may be viewed through the
customer “All Temps” menu or TTY output.
To access Offsets
1. Use Down to select “Offsets”.
2. Press Select .
3. Use Up and Down to scroll through available
thermistors.
To change offset
4. Press Select , the selected thermistor will begin to
flash.
5. use Up or Down to modify offset value.
6. Press Select to confirm setting.
To exit the Offset menu use Up to select “Return to
Menu” and press Select to confirm.
Self Test
ID
Description
States
Evap Fan
Evaporator Fan
0 - 100%
Condenser Fan
Condenser Fan
0 - 100%
Light
Zone Lighting
Off - Low - Med - High
Up
Select
Down
RETURN TO MENU
OUTPUTS
EVAP FAN=0%
CONDENSER FAN=0%
Up
Select
Down
RETURN TO MENU
OFFSETS
ZONE = 1°F
EVAP = 1°F
Can be displayed in Celsius
Up
Select
Down
RETURN TO MENU
SELF TEST
NO ERRORS
try “RELAY TOGGLE”