Problem
Possible Cause
Remedy
The unit is not
For model 29AD only:
cold enough
is the defrost timer set
(continued)
to the correct time of day?
See INITIAL START-UP
The unit is not cold The door was left open
Turn off the unit to manually
enough (Frost free
causing the evaporator
defrost the evaporator.
units only)
behind the back wall to
See DEFROSTING.
fill with frost preventing
proper air flow and cooling.
The unit frosts
Unit is manual
Models BI-15, 95, 98,
up
defrost model
and Combo 29A and
75A are manual defrost.
Refer to DEFROSTING
Door gasket not
Adjust door. See
sealing properly
ALIGNING THE DOOR
High ambient
Defrost unit manually.
temperatures or
See DEFROSTING
humidity
Water is leaking
Water supply
Tighten fitting. See
out the back
connection leaking
CONNECTING THE
of the unit
WATER SUPPLY
Ice cubes
Door gasket not
Adjust door. See
sticking together
sealing properly
ALIGNING THE DOOR
Infrequent use of cubes
Break apart cubes
Noise during
Copper water supply
Carefully bend tubing
operation
tubing contacting
away from cabinet and
internal components
components
Fan blade touching
Remove obstruction
obstruction (wiring,
foam insulation, etc.)
No ice
Bin arm locked in
Lower bin arm
upright position
Not enough ice
Control set too cold
Adjust control to a
warmer setting
(COUNTER-CLOCKWISE)
Ice cube size too
Set cube size smaller.
large
See ADJUSTING ICE
CUBE SIZE
Water leaks into
Water level set too
Set cube size smaller.
ice bucket
high
See ADJUSTING ICE
CUBE SIZE
Fresh food section
Ice bucket not fully
Push ice bucket
on Combo units
inserted
into place
too cold
Temperature control
Set control to warmer
set too cold
setting (COUNTER-
CLOCKWISE)
28
User’s Manual