background image

USER GUIDE

Thermistor 2

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • 

SERVICE

Thermistor Resistance Data

Temp (F)

Temp (C)

Nominal Resistance 

(OHMS)*

-40

-40

169157

-31

-35

121795

-22

-30

88766

-13

-25

65333

-4

-20

48614

5

-15

36503

14

-10

27681

23

-5

21166

32

0

16330

41

5

12696

50

10

9951

59

15

7855

68

20

6246

77

25

5000

86

30

4029

95

35

3266

104

40

2665

113

45

2186

122

50

1803

131

55

1495

140

60

1247

149

65

1044

158

70

879

167

75

743

176

80

631

* (+/-5%)

65

Содержание 124BEV

Страница 1: ...SER GUIDE SERVICE MANUAL SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE 2000 Series 2260WC 60 cm Single Zone Wine Cellar RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962 ...

Страница 2: ... Grille Plinth Installation Door Swing Door Stop Door Adjust Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation Sabbath Mode Airflow and Product Loading U Line Wine Guide Recommended Wine Storage Service Wine Rack Installation Troubleshooting Wire Diagram Product Liability Warranty Claims Parts Ordering Replacement Parts R600a Specifications...

Страница 3: ...8 00 am to 4 30 pm CST T 1 414 354 0300 Service Email onlineservice u line com Parts Email onlineparts u line com GENERAL INQUIRIES U Line Corporation 8900 N 55th Street Milwaukee Wisconsin 53223 USA Monday Friday 8 00 am to 4 30 pm CST T 1 414 354 0300 Email sales u line com u line com CONNECT WITH US Designed engineered and assembled in WI USA WELCOME TO U LINE Congratulations on your U Line pur...

Страница 4: ...oughout this guide This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with this appliance DANGER This un...

Страница 5: ...ever install or operate the unit behind closed doors Be sure front grille plinth strip base fascia is free of obstruction Obstructing free airflow can cause the unit to malfunction and will void the warranty Failure to clean the condenser every six months can cause the unit to malfunction This could void the warranty Allow unit temperature to stabilize for 24 hours before use Do not block any inte...

Страница 6: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refrigeration appliances and follow these steps completely 1 Remove all consumable contents from the unit 2 Unplug the electrical cord from its socket 3 Rem...

Страница 7: ... F 10 C and 90 F 32 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are present condensation may appear on outside surfaces This is considered normal The condensation ...

Страница 8: ...g area dry If the detachable type electric supply cord is damaged it must be replaced by an equivalent cord available from the manufacturer or its service agent NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified electrician The unit requires a grounded and polarized 2...

Страница 9: ...the front grille plinth strip base fascia must NOT be obstructed CAUTION Unit can NOT be installed behind a closed cabinet door U Line products are designed and manufactured to be installed in the specified cutout openings shown and variance to the floors or cabinetry must be accounted for in your installation CUTOUT DIMENSIONS Metric measurements rounded and optimized 4 102 mm 7 178 mm 33 7 8 860...

Страница 10: ...ne com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 3 5 8 to 4 5 8 92 mm to 118 mm 33 11 16 to 34 11 16 856 mm to 881 mm 23 7 16 590 mm 23 5 8 600 mm Includes 3 4 20 mm integrated panel 10 ...

Страница 11: ...ut Dimensions in each unit s Installation Guide Each door can be opened individually one at a time without interference However to ensure unobstructed door swing opening both doors at the same time 1 4 6 4 mm of space needs to be maintained between the units Hinge by Hinge Installation Mullion When installing two units hinge by hinge 13 16 22 mm is required for integrated models Additional space m...

Страница 12: ... drill bit drill 3 pilot holes 5 8 16 mm deep into bottom of counter top Use the anti tip bracket as a template 4 Install 3 8x5 8 screws into the plate using a 2 Phillips head screwdriver SIDE MOUNT Side mount position is used when you are unable to mount the bracket to the underside of your countertop 1 Remove the pre installed anti tip bracket from the top mount position and align the bracket to...

Страница 13: ... total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Adjust the front legs to level the unit after it is correctly positioned in the opening INSTALLATION 1 Plug in the power electrical cord 2 Gently push the unit into position Be careful not to entangle the ...

Страница 14: ...20 lbs 10 kg It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed 1 Cut the panels to the dimensions listed in the diagram below 2 Optional Stain or finish panel to desired stain or color Be sure to closely follow the instructions provided by the manufacturer 3 Optional Install handles and hardware NOTICE ...

Страница 15: ...e door The appliance will need up to 34 1 2 876 mm to the underside of the counter to leave room for leveling adjustments A single prepared frame with insert must not weigh more than 20 lbs 10 kg Integrated Frame Preparation 1 Cut the main panel to the appropriate dimensions below For details see the drawings on the next page 2 Create the top design for the handleless feature and the 1 8 3 mm notc...

Страница 16: ...RVICE Handleless Integrated Frame Dimensions 3 4 20 mm 28 13 16 732 mm 2 3 4 70 mm 2 3 4 70 mm R 5 8 R 16 mm 1 8 3 mm 1 4 6 mm Wooden Insert Notch Depth 1 8 3 mm 2 3 8 60 mm 7 8 22 mm Ref Cutout for Frame Units Top Detail Insert Notch Top Design 1 8 3 mm 3 1 2 89 mm 23 1 2 595 mm Wooden Insert Dimensions 23 1 2 595 mm 16 ...

Страница 17: ... dimensions listed in the appropriate diagram on the next page 2 Optional Stain or finish panel to desired stain or color Be sure to closely follow the instructions provided by the manufacturer 3 Optional Install handles and hardware NOTICE The door panel must not weigh more than 20 lbs 10 kg It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits...

Страница 18: ...ted Panel Integrated Panel Integrated Frame Front Side Front Side 3 5 16 89 mm to 4 5 16 114 mm Floor Cabinet 3 5 16 89 mm 3 5 16 89 mm to 1 25 mm U Line Unit Extended Integrated Panel Extended Integrated Frame Floor Cabinet 3 5 16 89 mm to 1 25 mm U Line Unit Integrated Panel Panel can extend beyond the door frame A minimum of 1 25 mm from the floor is required for proper ventilation 18 ...

Страница 19: ...integrated frame is 2 3 4 70 mm The top bottom border of the frame must account for any additional length BACK SURFACE MUST HAVE AMPLE FLAT SURFACE TO MOUNT OVERLAY FRAME FLAT AND WITHOUT INTERFERENCE 2 3 4 MIN 70 mm MIN Integrated Frame 3 4 20 mm 23 1 2 595 mm 32 7 8 to 33 7 8 834 mm to 860 mm A minimum of 1 25 mm is required from the floor to the bottom of the extended integrated panel frame for...

Страница 20: ...a panel to match your surrounding furniture Finish front back and edges to prevent warping Carefully follow the manufacturer s recommendations for finish application and cure times 3 Apply double sided tape to the backside of the integrated grill plinth strip base fascia Use the diagram below for reference U Line recommends 3M VHB tape a high strength bonding tape 4 Remove backing paper from doubl...

Страница 21: ...pe will not damage panel finish upon removal 7 Using a 7 64 3 mm drill bit drill 6 pilot holes into the wood panel 1 2 12 mm deep using the holes in the door frame as a guide NOTICE It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardwood is installed 8 Locate 6 of the 6x 1 1 2 38 mm screws provided with your unit 9 Using ...

Страница 22: ...e fascia When using the unit the grille plinth strip base fascia must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing the grille plinth strip base fascia 1 Disconnect power to the unit 2 Loosen the two screws 1 3 Remove grille plinth strip base fascia 2 from unit Installing the grille 1 Align cabinet and grille holes and secure b...

Страница 23: ... installed adjacent to a wall 1 2 13 mm clearance is recommended from wall on hinge side to allow the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated panel frame Units have a zero clearance when installed adjacent to cabinets Wall 90 Door Swing Space Required For any Knobs or Pulls 1 2 13 mm 23 ...

Страница 24: ...approximately 90 2 Remove hinge cover by lifting top and bottom of hinge cover and sliding the cover inwards to remove from hinge 3 Once cover is removed slide hinge pin into hole as shown Pin should slide into place stopping the door at 90 if the pin does not go into the hole shown hold the door less than 90 open and try again 4 To fully seat the pin tap it lightly with a hammer 5 Carefully slide...

Страница 25: ...e that it is firmly in contact with the cabinet Also make sure the door gasket is not pinched on the hinge side of the door CAUTION Do not attempt to use the door to raise or pivot your unit This would put excessive stress on the hinge system Alignment and Adjustment Procedure 1 Open door and remove gasket near the hinges 2 Using a T 25 Torx Bit loosen each pair of Torx head screws on both the upp...

Страница 26: ...ove caps from screw heads on opposite side 2 on top and 2 on bottom Using 2 Phillips bit remove the 4 underlying screws Reinstall the screws and caps on the opposite side 5 Partially install screw 1 in the outer most holes on top and bottom Rotate door 180 align hinge over screw 1 and slide seat into position Reinstall screw 2 on top and bottom Tighten both screws and install hinge cover Align and...

Страница 27: ...t the factory Initial startup requires no adjustments NOTICE U Line recommends allowing the unit to run overnight before loading with product When plugged in the unit will begin operating under the factory default settings If the unit was turned off during installation simply press and the unit will immediately switch on To turn the unit off press 27 ...

Страница 28: ...ROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY OPTIONS ON OFF Press and release Unit will immediately turn ON or OFF Toggle lights Press and release to leave interior light on for 3 hours Glass door wine and beverage centers only Adjust refrigerator set point Press and release When the F or C in the display is flashing press to adjust the set point temperature View temperature in unit Press together ...

Страница 29: ...tain internal temperatures and set points View a full list of Star K certified U Line units at www star k org To enable Sabbath Mode 1 Press 4 and hold for ten seconds and release the F C symbol will flash briefly at the end of the ten second period 2 The interior light and control display 3 will go dark until user resets mode 3 NOTE Although the display will not be visible the temperature control...

Страница 30: ...r airflow to perform at its highest efficiency Do not block the front grille or the unit will not perform as expected Do not install the unit behind a door When loading your unit leave space between the evaporator and product loaded Anything in direct contact with the evaporator is subject to freezing When properly loaded your U Line unit will store up to 43 750 ml bottles of wine 30 ...

Страница 31: ...e subject of wine is your own palate Do not be afraid to make mistakes Experiment discover but most of all enjoy yourself and your new U Line product Guide To Common Styles Of Wine Matching Food and Wine Although there are no hard fast rules for matching wine to food observe some guidelines Delicate dishes should be accompanied by lighter more delicate wines Full flavored foods should be matched w...

Страница 32: ...he presentation of the cork has a rich and fascinating history dating back to the late 1800 s A phylloxera root louse devastation to the vineyards severely limited the supply of great wines Restaurateurs would remove labels on inferior wines and replace them with labels from superior wines This made it necessary for patrons to protect themselves by checking the branding on the cork to ensure that ...

Страница 33: ...hat sediment is left undistributed and particles are not suspended vibration in a storage environment is not an issue Wines can become flat or tired when voids and vacuums are created inside the wine bottle In order to create voids and vacuums within a liquid aggressive motion or shaking of the wine bottle would have to occur Terminology Description Acidity A critical element of wine that is respo...

Страница 34: ... Each U Line Wine Captain model is designed to impress and inspire anyone with an interest in wine by providing cellar conditions in stylish undercounter units U Line Wine Captain models offer stable storage temperatures a 50 internal relative humidity and protection from UV light rays U Line has the largest product offering available making storing presenting and sharing your wine effortless and ...

Страница 35: ...ed horizontal wine racks properly position the bottles so the wine remains in contact with the cork which ensures the cork does not become dry Larger diameter bottles may be stored on the shaded racks illustrated below NOTE After stocking allow unit to stabilize product temperatures for 24 hours Use These Racks For Larger Diameter Bottles Champange 1 2 3 4 5 6 7 35 ...

Страница 36: ...otchBrite will cause the graining in the stainless steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean integrated panels use household cleaner per the cabinet manufacturer s recommendations INTERIOR CLEANING Disconnect power to the unit Clean the interior and all remove...

Страница 37: ...e drain pan and possibly damaging water sensitive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in an open position 2 in 50 mm minimum 4 Allow the frost to melt naturally 5 After the frost melts completely clean the interior and all removed components See INTERIOR CLEANING 6 When the interior is dr...

Страница 38: ...en necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric current to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condenser unit Condenser may be cleaned using a vacuum soft brush or compressed air 1 Remove the grille plinth strip base fascia See GRILLE PLINTH INSTALLATION 2 Clean the conden...

Страница 39: ...e cabinet NOTICE Do not remove the track rails from the cabinet To insert wine racks in the cabinet 1 Align the left and right rack channels with the tracks in the cabinet Ensure an even track engagement on both sides by gently pushing the rack into the cabinet until it stops 2 Before reloading the rack ensure proper movement of the travel stops in the left and right track rails by pulling the rac...

Страница 40: ...it is returned to service 3 If ice is on the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be exposed to temperatures of 40 F 5 C or less the steps abo...

Страница 41: ... listed Compressor The compressor makes a hum or pulsing sound that may be heard when it operates Evaporator Refrigerant flowing through an evaporator may sound like boiling liquid Condenser Fan Air moving through a condenser may be heard Automatic Defrost Drain Pan Water may be heard dripping or running into the drain pan when the unit is in the defrost cycle TROUBLESHOOTING GUIDE DANGER ELECTROC...

Страница 42: ... openings and the time the door is open The time the internal light is illuminated This mainly affects product on the top rack or shelf Digital Display Shows 1 16 or 99 A factory test mode may be enabled Adjust the temperature to 99 and press the LIGHT icon Product Is Freezing Because product in contact with the rear wall may freeze ensure no product is touching the rear wall Adjust the temperatur...

Страница 43: ...LUG 220 240 VOLT PLUG OVERLOAD NEUTRAL WHITE 115v DARK BLUE 220 240v TO COMPRESSOR NEUTRAL WHITE 115v DARK BLUE 220 240v BLUE 115V LIGHT BLUE 220V 240V TO COMPRESSOR 1 10 CONTROL BOARD ZONE TEMP FUSE 16 8 9 1 6 1 10 5 EVAP TEMP L T DOOR SWITCH AMBIENT TEMP R B LIGHT L T LIGHT COND FAN EVAP TEMP R B DOOR SWITCH CAP P R O G R A M I N G T O D I S P L A Y OPEN A N T E N N A J9 J10 HOT LIGHT BLUE OVERL...

Страница 44: ...ent of a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the date and the servicer who removed the part If the service technician determines the damage is the result of installation issues water connection drain etc the c...

Страница 45: ...ashes 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may submitted with the warranty claim to document warranty status We also accept the following information to verify warranty status New Construction Occupancy Documents Closing Paperwork Final Billing Rem...

Страница 46: ...40 00 18 Hinge covers 2 pcs 80 54001 00 19 Hinge mounting hole covers 4 80 54024 00 20 Hinges 2 w screws and covers 80 54013 00 21 LED light strip and cover assy 80 54000 00 22 Leg Levelers 4 80 54019 00 23 Main board no case or wires 80 54008 00 24 Packaging 80 54159 00 25 Rack assembly 80 54010 00 26 Rack assembly bottom 80 54091 00 27 Rack assy lower 80 54817 00 28 Rack assy middle 80 54818 00 ...

Страница 47: ...ts will be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original parts we will inform you when the parts order is taken This requirement will be noted on your packing list A prepaid shipping label will be included with the repla...

Страница 48: ... federal state and local laws regarding refrigerants Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when mixed with air Keep a dry powder type fire extinguisher in the work area R 600a is heavier than air do not allow any leakage migration to low areas such as basements and stairs Never use a torch on a fully charged refrigeration system Never substitute U L...

Страница 49: ...y equipment should be at least 10 feet from the work area It is recommended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system prior to brazing any part of the sealed system Only a clean dry leak free system should be charged with R 600a R 600A SPECIFICATIONS LABELING R 600a equipped products are labeled both the unit and the compressor R 600...

Страница 50: ...the system prior to repair simple venting is not sufficient Evacuate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required When re brazing the system must be purged with dry nitrogen and at least one access point open to the atmosphere When re brazing proper ventilation is required along with constant monitoring for the presence of R600a refrigerant The filt...

Страница 51: ...pe access port on the compressor process stub Evacuate the system to 100 microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minutes to clear the charging hoses Seal the Schrader Type access port a proper cap and seal must be used to close the system SUMMARY Safely handling R 600a requires proper procedures and training R 600a approved service...

Страница 52: ...e Lower than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room temperature Very hot Top passes warm Lower passes cool near room temperature due to liquid Room temperature cool or colder Extremely cold near inlet Outlet below room temperature backing up Lower ...

Страница 53: ...grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the C and S pins To measure the run winding resistance measure across the C and R pins Also check S to R and you should get the sum of the run and start windings To ensure the windings are not shorted check the S and R to groun...

Страница 54: ...outputs located on the relay power board Included in this section are some diagnostic tips and of course if additional help is required please contact the U Line Corp Customer Care Facility at 1 800 779 2547 for assistance NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components D...

Страница 55: ...Refer to 14 Error Log in Service Mode Thermistor failure Check Error Log in Service Mode OHM thermistor Frost Buildup Inside Unit Door Ajar or Restricted from Closing Check door clearance to adjoining cabinetry Check distribution of product in unit Evaporator fan not operating Use Relay Toggle Component Testing in Service Mode Thermistor failure Check Error Log Display Not Working Unit placed in S...

Страница 56: ... into overload The compressor will automatically deactivate during an overload and will remain deactivated until the overload switch cools This could take some time It is important to allow the compressor at least 5 minutes off time between relay cycles 2 Toggle the relay Its related component should activate deactivate with the switching of the relay If it does not test component Other Suspected ...

Страница 57: ...ed magnetic force pulls the reed to its contact and closes the circuit which turns the light and display off When the door is open the reed pulls away from the contact and opens the circuit If the door is left open for longer than 5 minutes the switch will trigger an error code and set an audible warning Magnet Close To Switch Door Closed Switch Closed Magnet Away From Switch Door Open Switch Open...

Страница 58: ...igates through service menu LED activated with button activation 3 Down Button Decreases temperature Navigates through service menu LED activated with button activation 4 Light Button Activates light for 3 hours on select models Used to select items in service menu LED activated with button activation 5 Power Button Turns unit off on LED activated with button activation only turning unit off 6 Cle...

Страница 59: ...nter exit this mode hold the light key and the power key for 5 seconds The display will flash once and beep and the degree symbol will begin to flash When the degree symbol is flashing the unit will allow the use of the control for demonstrations The unit can be left in this mode indefinitely SERVICE MODE This mode has options available for service diagnostics To enter the mode hold the hidden key...

Страница 60: ...in the refrigerator section 13 ADJUST DEFROST DURATION 0 TO 99 MINUTES The length of the defrost can be adjusted 0 to 99 minutes long The other defrost parameters still apply Lengthening a defrost may cause higher than normal temperatures in the refrigerator section Service Mode Menu Item 1 View thermistor 1 no offsets 2 View thermistor 2 no offsets 3 View thermistor 3 no offsets 4 View thermistor...

Страница 61: ...an will continue to run at the end of a cooling cycle Adjustable 0 99 minutes 19 INDIVIDUAL COMPONENT TOGGLE 20 MODEL NUMBER INDICATOR Displays the two digit model number of the specific unit See model list table 21 LIGHT ALL LED SEGMENTS This will illuminate all the LEDs on the display to ensure they work properly 22 VIEW DEFROST CYCLES Displays the number of defrosts that have occurred in the pa...

Страница 62: ...econds use the up and down arrow buttons to select the appropriate model number See Above Model List 5 Press the light bulb button once 6 The display will blink and then will appear as the programmed display 1000 MODEL INDICATOR 2000 120V MODEL INDICATOR 2000 230V MODEL INDICATOR 1215R 07 2218R 05 2245R 55 1215WC 12 2218RGL 04 2245DC 54 1224BEV 13 2218WC 06 2245WC 56 1224DWR 08 2224BEV 00 2260DC 5...

Страница 63: ...ht Evaporator Fan Condenser Fan N A N A 2218WC N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2224BEV N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2224R N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2224RGL N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2224WC N A N A N A N A N A Compress...

Страница 64: ...he Control Operations Service section This unit has three thermistors Thermistor one Zone Located along the right hand side wall It is used to maintain the operating temperature within that zone Thermistor two Evaporator Located on the evaporator It is used for defrost Thermistor three Ambient Located in the base of the unit secured to the condenser It is used to monitor the ambient temperature wi...

Страница 65: ...ata Temp F Temp C Nominal Resistance OHMS 40 40 169157 31 35 121795 22 30 88766 13 25 65333 4 20 48614 5 15 36503 14 10 27681 23 5 21166 32 0 16330 41 5 12696 50 10 9951 59 15 7855 68 20 6246 77 25 5000 86 30 4029 95 35 3266 104 40 2665 113 45 2186 122 50 1803 131 55 1495 140 60 1247 149 65 1044 158 70 879 167 75 743 176 80 631 5 65 ...

Страница 66: ...F C 1224 RF 12 45 15 9 1215 1224 2218 2245 2224 2260 WC ZWC 12 45 45 7 1215 1224 2218 2245 2224 2260 R RSOD RDC BEV DC DWR RGL 12 45 42 6 CO29 F 12 18 n a CO1224 F 12 18 45 7 1224FZR Freezer Mode 6 45 42 6 1224FZR Refrigerator Mode 12 45 42 6 Defrost Settings by Zone 3000 Series Zones Compressor Run Time Between Defrost Hours Duration in Minutes Minimum Duration in Minutes Maximum Stop Temperature...

Страница 67: ...e air and clear any condensation that may have appeared on glass doors and shelves Note If the unit is set to sabbath mode the evaporator fan will no longer respond to the state of the door switch In order to operate efficiently the evaporator fan blade and vents should be unobstructed and free of any dust buildup Evaporator Fan Replacement Should the evaporator fan need to be replaced follow the ...

Страница 68: ... wire NOTICE Fan must be oriented to pull air in through lower evaporator cover vents and push air out at fan mounting location 15 Installation is the reverse of removal 16 Care must be taken to assure the bottom of the evaporator cover is reinstalled behind the front edge of the drain trough 17 Use sealant gum to seal any openings at rear of unit before reinstalling rear cover 18 Reinstall unit t...

Страница 69: ...anty arising by operation of law U Line will not be responsible for any consequential or incidental damages arising from the breach of these warranties or any other warranty whether express implied or statutory Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you These warranties give you specific lega...

Отзывы: