NEO-M9N - Integration manual
Casting
If casting is required, use viscose or another type of silicon pottant. The OEM is strongly advised to
qualify such processes in combination with the module before implementing this in the production.
Casting will void the warranty.
Grounding metal covers
Attempts to improve grounding by soldering ground cables, wick or other forms of metal strips
directly onto the EMI covers is done at the customer’s own risk. The numerous ground pins should
be sufficient to provide optimum immunity to interferences and noise.
u-blox makes no warranty for damages to the module caused by soldering metal cables or
any other forms of metal strips directly onto the EMI covers.
Use of ultrasonic processes
Some components on the module are sensitive to ultrasonic waves. Use of any ultrasonic processes
(cleaning, welding etc.) may cause damage to the GNSS receiver.
u-blox offers no warranty against damages to the module caused by ultrasonic processes.
5.3 Packaging
The NEO-M9N modules are delivered as hermetically sealed, reeled tapes in order to enable efficient
production, production lot set-up and tear-down. For more information about packaging, see the u-
blox Package Information Guide [
].
5.4 Tapes
shows the feed direction and illustrates the orientation of the NEO-M9Ns on the tape:
Figure 43: Orientation of NEO-M9N on the tape
The dimensions of the tapes for NEO-M9N are specified in
UBX-19014286 - R07
5 Product handling
Page 88 of 95
C1-Public