TZ Centurion

™ 

Bridge

TZ Centurion

 Bridge Model 7130CF Series 

2. Best Practices

It is always best to plan out your cabling before installation  

to ensure that you have the proper cable lengths on hand 

when you start installation of the TZ Centurion system. Plans 

and cable requirements will differ significantly depending on 

the layout of the system, infrastructure and type of cabinets  

and doors.

Be aware that there are several different types of cabling and 

communication protocols used in the TZ Centurion System.

To connect the TZ Centurion Bridge to the existing 

network, standard straight through UTP CAT5e/6 with 

RJ45 connectors is required. The TZ Centurion Bridge 

communicates across the network via standard Ethernet 

(802.3) protocol.

Cabling between the TZ Centurion Bridges, TZ Centurion 

Port Links, TZ Radial devices, TZ SlideHandle devices 

and TZ Centurion RFID / Wiegand Translator devices is 

also via standard straight through UTP CAT5e/6 with RJ45 

connectors. However, the TZ Centurion Bridge uses the  

RS-485 serial protocol to communicate with the TZ Centurion 

Port Links, TZ Radial devices, TZ SlideHandle devices and 

TZ Centurion RFID / Wiegand devices.

It is common practice to use cabling of different colours 

for different traffic in the data center. (blue = data, white 

= VoIP, purple = 1GB backbone, etc.) The CAT5e/6 cable 

between TZ devices and/or cabinet patch panels should be 

differentiated by colour from the cabling carrying Ethernet 

traffic in the data center or building.

As CAT5e/6 cables connecting TZ intelligent locks to TZ 

Centurion Port Links may be routed inside a cabinet door 

and be subjected to flexing as the door is opened and 

closed.  As such, it is recommended to use UTP Stranded 

CAT5e/6, and that the cables be tucked away and well 

secured to appropriate surfaces.

For cable used for infrastructure from a cabinet back to a 

TZ Centurion Bridge it is recommended to use UTP Solid 

CAT5e/6.

The maximum cable length from a TZ Centurion powered 

devices (Bridge or Multi Port Link) to a TZ TZ SMArt locking 

device is 100 m / 328 ft.

The Temperature, Humidity and Liquid sensors use 2 m /  

6.6 ft. of standard 4-conductor cable that end in a terminal 

block. This plugs into the TZ Centurion Port Links. If 

necessary, the cable can be looped and secured or cut to 

length if distances are shorter. 

The door sensors for the TZ SlideHandle locks have a 1.2 m 

/ 4 ft. length of 2 wire cabling attached to them. They may be 

cut to length, as the cabling layout requires. Due to various 

cabinet designs and materials, door sensor placements 

have to be tested prior to final placement. Initial testing can 

be done with a volt-ohm meter or the “continuity / beep” 

function on a multi-meter. Final placement of the door 

sensors should be confirmed with the TZ Centurion system 

running to ensure that the contact closure is registering 

properly with the software interface. See the TZ Sensor 

manual for more detailed instructions.

Содержание Centurion 7130CF

Страница 1: ...ary 2015 Document Number 112365 01_D A TZ Business ixp tz net 2015 TZ TZ Centurion TZ SlideHandle TZ Radial TZ SMArt and TZ Sensors are trademarks of TZ Limited Patents Pending Product Manual TZ Centurion Bridge Model 7130CF Series ...

Страница 2: ...ide basic technical information related to the TZ Centurion Bridge model 7130CF This document is not meant to be an exhaustive statement of all relevant data By using this document however you agree to accept and comply with the terms conditions notices and disclaimers contained in this document While TZ has used all due care and skill to ensure that the information contained in this document is a...

Страница 3: ...ter 7 6 2 Within a Subnet 7 7 TZ Centurion Bridge Ethernet Configuration 8 7 1 TZ Centurion Bridge Settings 8 7 2 Network Settings Sub Tab 9 7 3 SNMP Configuration Sub Tab 10 7 4 Auxiliary IO Sub Tab 15 7 5 Device Licensing Sub Tab 16 7 6 Device Status Tab 17 8 Configuring TZ Network Devices Network 19 8 1 Configuring TZ Radial Devices 20 8 2 Configuring RFID Readers 21 8 3 Configuring TZ SlideHan...

Страница 4: ...pes The TZ Centurion Bridge is capable of monitoring and controlling a total of 32 users web UI 8 32 or 70 TZ SMArt locking devices TZ intelligent locks and or TZ RFID readers and 500 unique RFID cards Larger installations may require the TZ Centurion Server to coordinate multiple TZ Centurion Bridges 1 1 Introduction Telezygology Inc TZ is the inventor of intelligent fastening locking and actuati...

Страница 5: ...m Example Figure 2 shows an example of a TZ network system that may be used to control and monitor multiple computer racks and provide access to authorised parties when warranted The TZ network allows an administrator on or off site to monitor and control cabinets and other areas secured with TZ intelligent locks and devices Each of these components is controlled by the TZ Centurion Bridge allowin...

Страница 6: ...P purple 1GB backbone etc The CAT5e 6 cable between TZ devices and or cabinet patch panels should be differentiated by colour from the cabling carrying Ethernet traffic in the data center or building As CAT5e 6 cables connecting TZ intelligent locks to TZ Centurion Port Links may be routed inside a cabinet door and be subjected to flexing as the door is opened and closed As such it is recommended ...

Страница 7: ...nnected only to PoE networks routed within the facility Two status LEDs Eight RJ45 ports that accept RJ45 8P8C plugs used to make connections to the TZ device network Note These accept the same Category 5e 6 Cat 5e 6 cabling used in Ethernet connections However the TZ Centurion Bridge communicates to devices attached to it locks and readers via RS 485 serial communications NOT 802 3 Ethernet These...

Страница 8: ...FID Readers and other devices are all plugged into any of the eight RJ45 ports on the face of the unit Devices may be connected to the TZ Centurion Bridge with up to 100 meters of standard Cat 5e 6 cable More than one device can be connected to any leg that emanates from the TZ Centurion Bridge by daisy chaining the connection through the use of TZ Centurion Port Link or Multi Port Link devices If...

Страница 9: ...ts in the front of the unit Connect the TZ Centurion Bridge to an available 10 100 1000Mbps port on the local Ethernet network by using Cat5 6 cable If the Ethernet complies with the IEEE 802 3af Power over Ethernet standard the unit will start up Note that the TZ Centurion Bridge is to be connected only to PoE networks within the facility If necessary connect the 24V power supply to the jack in t...

Страница 10: ...h the unit The program may also be downloaded from the website http www tz net products tz centurion The program must be run on a computer that is running Microsoft Windows 7 or higher that is on the same subnet as the TZ Centurion Bridge The TZ Centurion Bridge Console will display a screen showing the IP address MAC address and name of the TZ Centurion Bridge devices on the local subnet as shown...

Страница 11: ...first sub tab is labeled About this Centurion Bridge and it contains all of the basic product firmware and serial number information The Primary and Secondary Name which is only used when the device is located with the TZ Centurion Bridge Console or when the TZ Centurion Server is used to control the device are set in this sub tab The units of measurement for the sensors Celsius or Fahrenheit are ...

Страница 12: ... IP address will likely change over time based on the IP lease policies of the local system administrator But the IP address can always be found by using the TZ Centurion Bridge Console utility as described in Section 6 TZ recommends using a Static IP Address when that option is available Using a Static IP Address allows the URL IP Address used to access the TZ Centurion Bridge to remain constant ...

Страница 13: ...standard contact information for the device usually a name phone number or email address mib 2 system sysContact System Location Field to set the mib 2 standard location information for the device mib 2 system sysLocation Read Only Community string Settable string indicating the community whose members can query Get GetNext the The TZ Centurion Bridge s SNMP database but not write Set the values T...

Страница 14: ...m standard SNMP traps They are as follows coldStart Indicates the system has restarted and a ROM value has been changed This indicates that the device array has been reset or modified by use of the reset switch on the back of the bridge warmStart Indicates the bridge has gone through a normal maintenance reboot or user initiated power cycle No changes were made to the internal ROM and execution ha...

Страница 15: ...1 4 Read Write String Community string traps are sent to for NMS devices that support this feature 7 3 2 3 Devices Section OID tz centurionBridge 1 3 The devices section of the TZ mib file exposes specific device control variables and traps for accessing and controlling TZ locks and other devices attached to the Bridge The following sections define the values traps and control variables in the dev...

Страница 16: ...der for the table holding device info deviceEntry 2 1 N A Table Entry OID space holder for entry in device Table deviceInde 2 1 1 0 deviceNumber 1 Read Only Table Key Position Key of device in table deviceName 2 1 2 0 deviceNumber 1 Read Write String Device primary name deviceName2 2 1 3 0 deviceNumber 1 Read Write String Device secondary name humidityAlarm 2 1 13 0 deviceNumber 1 N A Integer This...

Страница 17: ...3 Unused Temperature 0 1 Current Reading Unit Dependent x 10 eg 270 decimal 27 C eg 720 decimal 72 F 2 0 1 Associated Input 01 Device attached to Input 1 10 Device attached to input 2 00 invalid 2 6 Unused 7 Status of Alarm 1 Alarm has been set 0 Alarm was set but has been cleared 3 Unused 7 3 2 3 5 Enable Setting of Device Values The final value in the devices section of the TZ mib file is the al...

Страница 18: ...onality The Bridge s inputs are simple digital contact closures and are always set accordingly The Bridge s Auxiliary outputs have two different settable functionalities The default Output Function for these outputs is as an alarm indicator Setting an Auxiliary output as Alarm Output enables it to be actuated in the event of an alarm This setting works in conjunction with the Output Type when appl...

Страница 19: ...Sub Tab Typically the TZ Centurion Bridge is provided with a license already loaded right out of the box but in some cases it might be necessary reinitialise a license in the field Valid licenses can be entered into the Device Licensing sub tab of the System tab as shown below A TZ Centurion Bridge s current license can be manually stored to an SD card using the Export License to SD button When ne...

Страница 20: ...trayed in Table 1 on the following page To open a particular lock click on the door sensor icon The lock will open immediately and the door state icon should change from closed to open If the device is a TZ SlideHandle or if a door sensor i e a reed switch or similar is connected then when closing the open icon will only change to the closed icon when the sensor also reports a closed door To unloc...

Страница 21: ...r State Description Solid Red Handle is down unlocking is not enabled door is closed Solid Green Handle is up via authorised access unlocking has timed out door is open Handle is up via authorised access unlocking is enabled door is open Flashing Orange Handle is down unlocking is enabled door is closed Handle is down unlcoking is enabled door is open For example after handle was inadvertently clo...

Страница 22: ...k the TZ Centurion Bridge must be instructed to discover the device within its network This is done by clicking on the Start Discovery button found under the Settings subtab of the System tab as shown below in Figure 14 Once this is done go back to the Device Config tab and click the Edit button to display a screen that allows specific settings to be edited for each specific device as explained in...

Страница 23: ...ther it is put into a mode push to release that waits to sense a push on the door to which the device is attached When the TZ Radial senses this pressure it automatically ejects the stud thus opening The Unlock TimeOut field defines how long the TZ Radial stays in this ready mode Auxiliary Input Name String used to describe the device attached to the auxiliary input temp sensor humidity sensor etc...

Страница 24: ...Z Centurion Bridge Model 7130CF Series 8 2 Configuring RFID Readers If there are any RFID readers or Wiegand devices on the TZ network they will show up on the Device Configuration tab not the Device Status tab and their basic information can be found and edited by clicking the appropriate Edit link as shown in Figure 16 below Figure 16 Configuring a TZ Centurion RFID Reader ...

Страница 25: ...h some information may not be editable in order to reflect specific functionality differences in the hardware e g TZ SlideHandle AuxIn2 is configured to be a door sensor This is shown in Figure 17 below 8 4 Downloading Logs Under the Device Config tab there are buttons which allow users to download the different logs stored within the non volatile memory of the TZ Centurion Bridge 8 4 1 Download S...

Страница 26: ... being added to the system etc from non volatile memory 8 4 3 Download Event Logs Clicking this button will download a text file containing the details of all the non alarm events e g doors being opened cards being swiped users being added to the system etc 8 5 Other Buttons under the System tab The buttons for Re booting the System updating the TZ Centurion Bridge firmware or clearing either the ...

Страница 27: ...imary and Secondary DNS When checked during a backup function the resulting file will be named TZIP dat When checked during a recovery function the system will look for the TZIP dat file and if found will load the data contained within back into the Network Settings Bridge Aux IO The Bridge Aux IO data includes the user settable information under the System About this Centurion Bridge tab includin...

Страница 28: ...econds to organize the data internally 8 5 4 Clear Event Logs Clicking this button will clear all of the event logs from non volatile memory 8 5 5 Clear Alarm Logs Clicking this button will clear all of the alarm logs from non volatile memory 8 5 6 Clear Sensor Logs Clicking this button will clear all of the data of the specified sensor from non volatile memory 9 Event and Alarm Logs An event occu...

Страница 29: ...is functionality is primarily defined through the Alarm Config tab although some preliminary set up may be required in the Device Config tab If the reading from a particular sensor is to be used for the alarm then confirm that the sensor is configured correctly For example if an alarm is required to monitor temperature then make sure that a temperature sensor is connected to the appropriate radial...

Страница 30: ...b if the alarm is ever tripped Source Select the appropriate sensor by choosing the proper input from the Source dropdown box Minimum Trigger and Reset Values When the reading from a sensor reaches below the Minimum Trigger value the alarm will activate and will continue to be active until the reading rises above the Minimum Reset value Maximum Trigger and Reset Values When the reading from a sens...

Страница 31: ...s add RFID users and view log events The TZ Centurion Bridge supports up to 16 Login Users Clicking on the Add User button will bring up the above screen Enter the appropriate information in the Login Name Password and Full Name fields and check all of the devices that this user should be able to view when he or she is logged in The check boxes under the Permissions label are used to determine whi...

Страница 32: ...ing the Device and Recovering Configurations If the TZ Centurion Bridge is not operating properly the unit can be reset and rebooted by disconnecting and reconnecting the power The unit will reset and all of the configurations definitions and log entries e g what devices are connected what users are allowed to do and what alarms are defined will be reread from non volatile memory To perform a full...

Страница 33: ...to C 67 F to 0 C 122 F e connected d rnet IEEE 802 interface via R 3 4 Not Us UL all in progre Warranty tz net Te 112345 01_D application re 1 compromises roduce metal s 131 F 185 F evices 3af RJ 45 sed 5 Gnd 6 ess TZ lezygology I quirements the Ingress P shavings arou 6 7 Not Use Centuri Model N Inc 2011 Protection IP und electronic ed 8 V ion B Number 7 rating of the e equipment ridge 7130CF enc...

Страница 34: ...e trademarks of TZ Limited Patents Pending TZ Centurion Bridge TZ Centurion Bridge Model 7130CF Series Appendix 2 1 U Rack Mount Adapter An optional 1U rack mount adapter part 112386 along with blanking plates part 112550 not shown are available for the mounting the TZ Centurion Bridge in standard computer racks ...

Страница 35: ...A TZ Business ixp tz net 2015 TZ TZ Centurion TZ SlideHandle TZ Radial TZ SMArt and TZ Sensors are trademarks of TZ Limited Patents Pending ixp tz net ...

Отзывы: