Digital Systems
9
ALARM
The DS512 in mode 3 and 4 (operating as VSS) has detected alarm
condition and is alarming.
ALARM_OEM
The DS512 has detected, that OEM CAN VSS has been triggered
(modes 2,3,4) .
ALARM_PAGER
The DS512 has detected, that monitored analogue VSS has been
triggered and is alarming (mode 1 - analogue Pager) .
LOCK_STATE
VSS system is armed / vehicle is locked.
LOCK_woTRUNK
VSS system is armed without trunk, rear door, additional sensor - the
3rd button on remote has been used.
DOOR (...)
Door is opened.
TRUNK
Trunk is opened.
BONNET (CAN)
Bonnet is opened - signal from OEM switch read from CAN-bus.
BONNET (switch)
Bonnet is opened - analogue signal read via gray wire(pin4) in modes (3
and 4).
DOOR/TRUNK/BONNET
The lamp signals if any input is triggered. If the lamp is on, the door
status in SMS is sent as opened, In mode 1 (analogue pager) that lamp
shows the status of monitored VSS inputs.
GLOBAL_IGNITION
The result of ignition signal - the sum of signals from CAN-bus and
analogue signal (orange wire).
IGNITION (CAN)
Ignition switch signal read from CAN-bus.
ACC (CAN)
ACC (ignition switch in accessory position) signal read from CAN-bus.
HZD_LEFT, HZD_RIGHT,
HAZARD LIGHTS
Direction indicators and hazard lights status.
STATUS1-
Status of additional analogue ground signal connected to blue wire (pin
4), necessary for CAN-bus connections on some vehicles (e.g. Renault
Clio).
Status of additional positive analogue signal connected to orange wire
(pin 3), necessary for CAN-bus connections on some vehicles (e.g.
Subaru Forester).
SEND LOCK,
SEND UNLOCK,
SEND UNLOCKTRUNK
SEND HAZARD LIGHTS
SEND CLOSE WIN
The lamps show that DS512 is sending CAN-bus commands to the
vehicle, that control the vehicle circuits (power door locks, hazard lights,
power windows).
PA button / ultrasonic
The lamp show that the PA button is pressed or the additional sensor
input is triggered.
LED
The lamp repeats the LED state.
ALARM STATE
Device is in alarm state - it is alarming or there was an alarm since last
arming
EXT_SENSOR_INP
Additional sensor input is active
EXT_SENSOR2_PRE
The lamp shows that additional sensor No2 Prealarm input was
triggered.
EXT_SENSOR2
The lamp shows that additional sensor No2 Alarm input was triggered.
Columns 6-7 show the status of device analogue inputs / outputs.
Lamp
Description
OUT_IMMORELAY
The lamp shows that the immobilisation relay output is active -
connected to ground.
OUT_HAZARD
The lamp shows that the hazard lights control output is active -
connected to ground
OUT_SIREN
The lamp shows that the siren control output is active - connected to
ground
OUT_LED
The lamp shows that the LED control output is active - connected to
ground
AI0 (pin9),
DI0 (pin6), DI2 (pin4),
DI1 (pin3), DI5 (pin5),
The lamps show the physical state at the given input. The lamp lights up
if the voltage at the input is positive. That is why the PA button and
STATUS1- inputs, which do have internal pull-up are displayed as
active.
Содержание DS 512
Страница 1: ...Vehicle Security System GSM SMS Pager DS 512 CAN GSM GPS INSTALLATION MANUAL ver 0 14 ...
Страница 16: ...16 tytan Diagram No 2 Mode 2 OEM VSS CAN Pager ...
Страница 19: ...Digital Systems 19 Diagram No 5 connections necessary for anti hijack remote stop function in modes 1 2 3 ...
Страница 20: ...20 tytan Diagram No 6 connection of RF receiver module with analogue power door lock control ...
Страница 21: ...Digital Systems 21 Diagram No 7 connection of second additional sensor with pre alarm ...