background image

 

TYROLIT Hydrostress AG 

9

 

Technical data 

9.1

 

Dimensions 

Parameter Value 

Weight 610 

kg 

Cutting depth (max.) 

480 mm 

Blade uptake diameter 

25.4 mm 

Max. saw blade diameter 

1,200 mm 

Dimensions (transport dimensions with blade 

guard folded up) 

L: 1,700 mm 

W: 870 mm 

H: 1,160 mm 

 

 

9.2

 

Motor 

Parameter Value 

Type Electric 

 

Power 30 

kW 

Voltage 400 

Rated speed 

1,800 rpm 

Cooling Air 

cooling 

Grease 

Polyrex EM (Exxon Mobil) 

Ampere (power) 

44 Amps 

Power cable connection 

up to 25m 

5 x 10mm2 

 

25 - 50m 

5 x 16mm2 

Mains fuse protection 

(Neutral conductor (Earth + residual current 

circuit breaker imperative) 

min. 63 Amps 

 

 

 

9.3

 

Lift drive 

Parameter Value 

Drive type 

Electro-hydraulic 

 

 

Floor Saw FSE1240



 

Page 21 

Содержание FSE1240

Страница 1: ...10987503 en 07 11 2008 Operating Instructions Floor Saw FSE1240 Index 001...

Страница 2: ...o honour our warranty obligations Any repair work must be carried out by trained personnel only Should you need more details concerning your TYROLIT Hydrostress unit in order to keep it in perfect con...

Страница 3: ...er with the Safety Manual System Description for Floor Saws to form a complete set of documentation DANGER Failure to comply with the safety instructions in the Safety Manual System Description may re...

Страница 4: ...e plate 3 Main motor 4 Front cut guide 5 Shaft cover 6 Blade guard 7 Saw blade 8 Rocker wheel 9 Drive wheel 10 Rear cut guide 11 Water feed 2 1 Saw blade drive Saw blade drive schematic 1 Blade drive...

Страница 5: ...drive Lift drive schematic 1 Hydraulic cylinder 2 3 Travel drive Travel drive schematic 1 Drive shaft main motor 2 Hydrostat drive belt 3 Hydrostatic motors 4 Drive chain 5 Wheel drive shaft 6 Drive...

Страница 6: ...s and load suspension devices with sufficient load bearing capacity must be used Floor saws must only be hitched by the hitching points provided Appoint an expert marshaller When transporting by crane...

Страница 7: ...TYROLIT Hydrostress AG 4 Initial start up 4 1 Fitting battery Fit battery for type see Technical Data Floor Saw FSE1240 Page 7...

Страница 8: ...TYROLIT Hydrostress AG 5 Assembly Set up 5 1 Mounting grip 5 2 Mounting saw blade 1 Apply hand brake Page 8 Floor Saw FSE1240...

Страница 9: ...ated with a blade guard When assembling the saw blade on the right hand side use the anchoring screw with the left hand thread When assembling the saw blade on the left hand side use the anchoring scr...

Страница 10: ...stress AG 4 C To prevent the saw blade rotating while being tightened carefully place the saw blade on the floor 5 3 Mounting saw blade on the other side 5 3 1 Disassemble the blade guard Page 10 Floo...

Страница 11: ...ble the shaft cover 5 3 3 Assembling the blade guard and shaft cover on the other side Assembly of the blade guard and the shaft cover is performed in the opposite order to disassembly 5 4 Connecting...

Страница 12: ...switch 8 Reset button 9 Rotating field selector switch 10 On Off control for internal water pump 11 On Off control for headlight 12 Raise Lower buttons 13 Feed adjuster forward backward travel 14 Key...

Страница 13: ...TYROLIT Hydrostress AG 6 3 Connecting the water supply Floor Saw FSE1240 Page 13...

Страница 14: ...ing lever in uncoupled position 9 Coupling lever 5 is in the uncoupled position 9 EMERGENCY STOP switch 2 has been released 1 Set key operated switch 4 to I 2 Press start button 1 3 Check direction of...

Страница 15: ...ample 1 Press the Lower button 3 until the saw blade touches the material to be cut 2 Set the cutting depth indicator 1 in the 0 position 3 Using the Lower key lower the saw blade to the desired cutti...

Страница 16: ...d position Feed adjuster in the forwards direction of travel Feed adjuster in the backwards direction of travel 9 Feed adjuster is in the neutral position 9 Hand brake has been released 1 Place coupli...

Страница 17: ...TYROLIT Hydrostress AG 6 7 Correcting the tracking Correcting the tracking 1 Saw blade If the saw blade drifts adjust the rear axle with the adjusting screw Floor Saw FSE1240 Page 17...

Страница 18: ...perating hours Arrange a major service by TYROLIT Hydrostress AG or an authorised representative 7 1 Grease nipples Position of grease nipples 1 Motor 2 items 2 Feed adjuster control rods 4 items 3 Wh...

Страница 19: ...TYROLIT Hydrostress AG 7 3 Tensioning chain on travel drive Tensioning chain 1 Chain Floor Saw FSE1240 Page 19...

Страница 20: ...d arrange repair as necessary Defective hydrostat Check hydrostat and if necessary have this repaired by a TYROLIT Hydrostress engineer Defective chain Have the chain replaced by a TYROLIT Hydrostress...

Страница 21: ...700 mm W 870 mm H 1 160 mm 9 2 Motor Parameter Value Type Electric Power 30 kW Voltage 400 V Rated speed 1 800 rpm Cooling Air cooling Grease Polyrex EM Exxon Mobil Ampere power 44 Amps Power cable c...

Страница 22: ...B A Vibrations DIN EN ISO 5349 2 2 5 m s2 Value applies under the following condition Travel drive is switched off and the saw blade is not engaged The measurement is performed with the motor under fu...

Страница 23: ...of cut 500 2450 4 12 5 6 1800 3VX560 4 130 600 2000 4 5 5 1800 3VX560 4 180 700 1700 5 4 75 1800 3VX560 6 230 800 1400 5 3 4 12 1800 3VX560 6 280 900 1400 5 3 4 12 1800 3VX560 6 330 1000 1075 6 9 4 12...

Страница 24: ...EC Standards EN 12100 1 Safety of machinery Basic concepts general design principles EN 12100 2 Safety of machinery Basic concepts and general principles for design EN ISO 14121 Safety of machinery Pr...

Отзывы: