TYROLIT Hydrostress AG
8
Malfunctions
Malfunction Possible
cause
Solution
Saw blade jammed
Saw blade is jammed in the cutting material
►
Reverse the floor saw.
►
If necessary release the saw blade by
rocking.
►
If necessary stop the motor, disassemble
the saw blade and release this
individually from the cutting material.
Belt tension too slack
►
Tension or replace belt.
Saw blade does not rotate even
though the motor is running
Pulling pin on the anchoring flange has
sheared off
►
Mount new anchoring flange.
Operation of the control rods impaired
►
Check control rods and arrange repair as
necessary.
Defective hydrostat
►
Check hydrostat and if necessary have
this repaired by a TYROLIT Hydrostress
engineer.
Defective chain
►
Have the chain replaced by a TYROLIT
Hydrostress engineer.
Feed not working
Main motor belt slipping
►
Check belt for wear and if necessary
have this replaced by a TYROLIT
Hydrostress engineer.
►
Increase belt tension as necessary.
EMERGENCY STOP
switch has been pressed.
►
Release
EMERGENCY STOP
switch.
Not plugged in to mains
►
Plug in to mains
Defective cable
►
Check cable and change as necessary.
Faulty electric motor
►
Have electric motor checked by a
qualified electrician.
Electric motor does not run
Wrong direction of rotation
►
Note rotary field warning lamp
►
Shift forward / reverse switch
Page 20
Floor Saw FSE1240
Содержание FSE1240
Страница 1: ...10987503 en 07 11 2008 Operating Instructions Floor Saw FSE1240 Index 001...
Страница 13: ...TYROLIT Hydrostress AG 6 3 Connecting the water supply Floor Saw FSE1240 Page 13...
Страница 19: ...TYROLIT Hydrostress AG 7 3 Tensioning chain on travel drive Tensioning chain 1 Chain Floor Saw FSE1240 Page 19...