typical GC6880 Скачать руководство пользователя страница 9

Parameter

Parameter Function

Range

Default

Description

P84

Thick start angle

0-330

9

P85

The thick end angle

0-330

57

P92

Encoder start angle

160

View manual 1.4 chapter

3

Error Code List

Error Code

Problem

Strategies

E1

Power Module is faulty.
Abnormal over current or voltage.
Resistor is damaged or F1 fuse is blown.

System will be shut down until the power resets on.
Please check the power board in detail.

E2

1

When power on, detected main voltage too low

2

Connect the wrong voltage, too low.

Moto and machine will be shutting down.
Please check the AC power. (Too low) Please check
the main pc board.

E3

Operation Box linked to CPU interface had
communication error.

Motor and machine will be shutting down.
Please check the operation box.

E5

The connection of the Foot Pedal error

Motor and machine will be shutting down.
Please check the connection of the Foot Pedal or the
problem of it

E7

a) Bad connection at the motor connector.
b) Machine locked or object stuck in the motor pulley.
c) Sewing material is too thick.
d Module output is abnormal.

Head rotation motor handwheel see if stuck. As the first
rule nose stuck mechanical failure.
As normal rotation, check the motor and motor encoder
connector power cord connector is loose. Please correct
if loose.
As good contact, check the power supply voltage is
abnormal or speed is set too high. If yes, please adjust.
As normal, replace the control box and inform the
manufacturer.

E8

Manual Back-Tacking lasts for 15 sec.

Reverse stitching solenoid pull too long, you can restart
the product.
If the product or reported after the restart E-08, check the
manual back tack switch is damaged.

E09
E11

Positioning signal error

Power off the system, check the motor encoder interface
is loose or fall off, it was back to normal after restarting
the system. If it still does not work, replace the motor
and inform the manufacturer

E14

Encoder signal error

Power off the system, check the motor encoder interface
is loose or fall off, it was back to normal after restarting
the system. If it still does not work, replace the motor
and inform the manufacturer.

E15

Power module abnormal over-current protection

Power off the system, then on again. If it still does not
work, replace the control box and inform the
manufacturer.

E17

Head protection switch is not in the correct position

Power off the system and check whether the nose open,
ball switch control box whether displaced or damaged.

E20

Power motor failed to start

Power off the system, check the motor encoder interface
and motor power connector is loose or fall off, it was
back to normal after restarting the system. If it still does
not work, replace the control box and inform the
manufacturer.

Содержание GC6880

Страница 1: ...INSTRUCTION BOOK FOR CONTROL GC6880 HIGH SPEED 1 NEEDLE FLATBED SEWING MACHINE...

Страница 2: ......

Страница 3: ...Turn off the power before the following operation a Connecting or disconnecting any connectors on the control box or motor b Threading needle c Raising the machine head d Repairing or doing any mechan...

Страница 4: ...ntents change after adjustment need to press the S key to save the confirmation Note The parameters are saved directly by the S key Mention needles fill needle key Continuous back seam except any kind...

Страница 5: ...ncoder Press the Screen display P 92 Save by ACcording to the At this point the motor will automatically turn a circle to find the reference point of the encoder After the motor stops Save by 2 User P...

Страница 6: ...ON At the end of Start Back Tacking machine continues sewing if pedal pressed or START signal on standing operation STP At the end of Start Back Tacking machine stops P14 Soft Start ON OFF ON ON Slow...

Страница 7: ...ckwise P44 Brake force 0 31 16 Efforts to stop the machine when selecting P45 Back seam operation duty cycle 10 90 30 Back seam action to periodic power output P46 Motor stops with a reverse angle aft...

Страница 8: ...d C 1 250 20 Setting running time of testing B and C P65 Stop Time of Testing B and C 1 250 20 Setting stop time of testing B and C P66 Machine Protection Switch Testing 0 2 1 0 Disable 1 Testing zero...

Страница 9: ...rrect if loose As good contact check the power supply voltage is abnormal or speed is set too high If yes please adjust As normal replace the control box and inform the manufacturer E8 Manual Back Tac...

Страница 10: ...4 Port Outline Diagram 4 1 The Name of each port 4 2 14P Function Port Table...

Страница 11: ...11 info vetrontypical com www vetrontypical com This machine may only be operated by adequately trained operators only after having completely read and understood the instruction manual Parts are subj...

Отзывы: