Parameter

Parameter Function

Range

Default

Description

P34

Mode Selection for

Constant-Stitch Sewing

A/M

A

A

One shot to pedal, it will automatic execute

Constant-Stitch
M

Pedal-controlled and motor can stop arbitrarily

P37

Wiper Function Selection or
Thread Clamp Pressure Setting

0-11

8

0 : No Action

1: Wiper Action

2-11: Thread Clamp action and the pressure gradually
increased

P38

Trimmer Function Selection

ON/OFF

ON

ON

Trimmer Valid

OFF: Trimmer Invalid

P39

Presser Foot UP / Down at
intermediate stop

UP/DN

DN

UP

Presser foot goes up automatically

DN

Presser foot keeps down

Controlled by heeling

pedal

P40

Presser Foot UP / Down after

Trimming

UP/DN

DN

UP

Presser foot goes up automatically

DN

Presser foot keeps down

Controlled by heeling

pedal

P41

Display the sewing finished

quantity

0

Counting the finished-sewing quantity

P42

Information Display

N-01

NO1 Electrically controlled version serial

numbers

NO2 Selected needle cassette version

NO3 Speed

NO4 Pedals AD,

NO5 Positioning angle (0--359),

NO6 Under the positioning angle

NO7 Bus voltage AD

P43

Setting Direction of Motor

Rotation

CCW/CW

CCW

CW

Clockwise

CCW

Counter Clockwise

P44

Brake force

0-31

16

Efforts to stop the machine when selecting

P45

Back-seam operation duty cycle

(

%

)

10-90

30

Back-seam action to periodic power output

P46

Motor stops with a reverse angle

after trimming

ON/OFF

OFF

ON

It will automatic as reverse function after

trimming (angle adjustment according to the
parameter

047.TR8

OFF

No Function

P47

Adjustment of reverse angles

after trimming

50-200

160

Adjusting at reverse direction after trimming

P48

Low (Positioning) Speed

r/S

100-500

210

Setting Positioning Speed

P49

Trimming Speed

r/S

100-500

250

Adjusting trimming speed

P50

The time of Foot lifting

10-990

250

Adjustment of foot lifting action

P51

Duty-Cycle Setting for Foot
Lifter

%

10-90

30

Adjustment for Duty-Cycle of Foot Lifter /

Back-Tacking (Fine tuning can reduce the

over-heating)

P52

The time of Foot down

10-990

120

Adjustment of foot down action

P53

Cancel Foot Lifting when
Half-Heeling the Pedal

ON/OFF

OFF

ON

Pedal half heeling without foot lifting function.

OFF

Pedal half heeling with foot lifting function

P54

Trimming Time

ms

10-990

200

Trimming sequence time setting

P55

Setting Wiper Timing

10-990

380

Wiper sequence setting

P56

Needles Goes Up Automatically
as Power turned on

0-2

1

0: always not to find a position
1

: always looking for positioning

2

If the motor is positioned on the no longer find

Содержание GC6880

Страница 1: ...INSTRUCTION BOOK FOR CONTROL GC6880 HIGH SPEED 1 NEEDLE FLATBED SEWING MACHINE...

Страница 2: ......

Страница 3: ...Turn off the power before the following operation a Connecting or disconnecting any connectors on the control box or motor b Threading needle c Raising the machine head d Repairing or doing any mechan...

Страница 4: ...ntents change after adjustment need to press the S key to save the confirmation Note The parameters are saved directly by the S key Mention needles fill needle key Continuous back seam except any kind...

Страница 5: ...ncoder Press the Screen display P 92 Save by ACcording to the At this point the motor will automatically turn a circle to find the reference point of the encoder After the motor stops Save by 2 User P...

Страница 6: ...ON At the end of Start Back Tacking machine continues sewing if pedal pressed or START signal on standing operation STP At the end of Start Back Tacking machine stops P14 Soft Start ON OFF ON ON Slow...

Страница 7: ...ckwise P44 Brake force 0 31 16 Efforts to stop the machine when selecting P45 Back seam operation duty cycle 10 90 30 Back seam action to periodic power output P46 Motor stops with a reverse angle aft...

Страница 8: ...d C 1 250 20 Setting running time of testing B and C P65 Stop Time of Testing B and C 1 250 20 Setting stop time of testing B and C P66 Machine Protection Switch Testing 0 2 1 0 Disable 1 Testing zero...

Страница 9: ...rrect if loose As good contact check the power supply voltage is abnormal or speed is set too high If yes please adjust As normal replace the control box and inform the manufacturer E8 Manual Back Tac...

Страница 10: ...4 Port Outline Diagram 4 1 The Name of each port 4 2 14P Function Port Table...

Страница 11: ...11 info vetrontypical com www vetrontypical com This machine may only be operated by adequately trained operators only after having completely read and understood the instruction manual Parts are subj...