44
45
Unit Specifications
Temperature Sensor
Temperature Sensor
Unit Specifications
Inflow
emperature Sensor
T
%
a
10:30
50
%
50
LCD:
TEMP ERROR
Should water with a temperature higher than 35
�
(95
�
) get into the unit, the water supply will
automatically be shut off, and the unit will stop
operating temporarily.
1
2
Bring the source water temperature within
the proper range.
3
When the source water is within the proper range,
the ionizer will resume proper function and water
will flow.
5
If you press the error icon,
the display will switch to
the previously used screen.
4
Hot water
nit Specifications
U
※
To ensure the best functionality, there may be some minor changes without notice.
11
Max 220W
13
Max 220W
YT22-4TL13D
YT22-4TL11D
Water Cell Plate
Materials
Water Ionizer
100 -130 V~ , 200 -240 V~ / 50-60 Hz
4 -35ºC ( 39 -95ºF )
0.1- 0.5 MPa
3 Alkaline, 1 Neutral, 3 Acidic, Turbo
User adjustable pH levels control
Dual .01 Micron Filtration System
LCD filter replacement and announcement
Platinum and Titanium
W300 x D135 x H355 mm (11.8 x 5.3 x 13.9 inches)
approx 5.0kg (11.1 Lbs )
Product Name
Rated Voltage
pH Levels
Adjustable pH
Filter Configuration
Filter Life Display
Product Size
Product Weight
Electrolytic Cell
Quantity of Plates
Operating
Pressure Range
Available
Temperature
Model Number
Power Consumption
TURBO Function