Tycon Power Systems Wireless EZ-Bridge AC Скачать руководство пользователя страница 7

7

 

ture built into the housing back fin. The Ethernet spec allows for a maxi-

mum cable length of 100 meters or about 328 feet.

 

STEP 10:

 Connect the device needing network connectivity to the LAN 

port of Side B

s PoE inserter. 

 

Advanced Features

 

Since documentation for the advanced features is too extensive to cov-

er  here  please  visit  our 

online  wiki 

at 

https://tyconsystems.com/

support?view=kb&kbartid=25

 

 

 

FAQs

https://faq.tyconsystems.com

 

 

Knowledge Base

https://tyconsystems.com/index.php/support?

view=kb

 

 

Software Settings

 

 

We strongly recommend that you create a working plug 

and  play  link  before  making  ANY  changes  to  the  soft-

ware settings

 

1. There is an HTML management system (control panel) built into eve-

ry EZ

-

Bridge

®

 unit which is accessed thru a standard web browser. The 

unit can communicate thru the CAT5/6 Ethernet cable connection or  

with an established link, through the wireless bridge connection, so you 

can manage remote units from a single location.

 

NOTE: 

The device will usually go into a  2

-

3 minute reboot cycle when 

clicking on SAVE & APPLY CHANGES. During this time it will be unre-

sponsive. The unit will beep once when it reboots and beep twice when 

it is ready.

 

2. 

IP  ADDRESS: 

Default fallback IP addresses for the EZ

-

Bridge

®

 are 

192.168.1.139  and  192.168.1.239.  To  access  the  EZ

-

Bridge

®

  control 

panel,  your  computer  IP  address  must  be  on  the  same  subnet  ie; 

192.168.1.xxx. The EZ

-

Bridge

®

 ships with DHCP client enabled so if the 

unit  has access to  your network it will get its IP address automatically 

from your network. To find the units IP address use the Discovery Tool 

which is available at https://support.tyconsystems.com. We recommend 

after everything is working to your satisfaction that you assign a unique 

static IP  to each unit so  you  always know how to  access the  units on 

your network. The IP address setting can be changed at 

INTERFACES 

| LAN | EDIT

 

TECH TIP

: We recommend always making changes to the remote 

unit first and the local unit second. The EZ Bridges are shipped with 

the  two  antennas  paired  up.  No  additional  changes  on  the  settings  is 

Содержание Wireless EZ-Bridge AC

Страница 1: ...oint to Point Wireless Bridge System Achieve up to 867 Mbit sec speed Link up to 3 miles with good line of sight Plug and Play Simple Installation Best security available WPA Field Proven Wireless Technology Now with TyconOS Firmware ...

Страница 2: ...ess Antenna System Router Internet Source PC Note The EZ Bridge AC accepts standard 802 3af at bt PoE or 48V Passive PoE ETH0 Connector accepts PoE ETH1 for data only Antenna A Router LAN Port POE Port LAN Port WAN Port ...

Страница 3: ...r Switch PC Typical IP Device s Cameras Access Points Radios Other Simplified Hook Up Diagram All connections beyond this point must happen after EZ Bridge Set Up and Verification Tests LAN Port POE Port LAN Port LAN Port ...

Страница 4: ...rform as many functions as possible on the ground Do not attempt to install the antenna on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet Make sure there are no people pets etc below when you are working on a roof or ladder Watch out for any power lines which may be overhead under ground or behind walls keeping safely clear of them with...

Страница 5: ...antenna ETH0 RJ45 jack closest to the LEDs Plug a PC directly to the LAN port of the B side power inserter Plug in the PoE power insert er to the AC outlet to power up the bridge You will hear 2 beeps from the antenna when it is ready 2 3 mins Place the antennas a few feet away from each other facing opposite directions or face down on the floor STEP 4 Turn the computer s Wi Fi off and try to pull...

Страница 6: ...hten wing nut Use pliers if additional tightness is needed TECH TIP Because of the specially designed wide beam width antenna pointing is not critical and simply pointing in the general direction of the receiving antenna will yield great results At longer dis tances it requires more accurate alignment STEP 8 Route an Ethernet ca ble through the bottom cover and plug into the ETH0 RJ45 jack closest...

Страница 7: ... units from a single location NOTE The device will usually go into a 2 3 minute reboot cycle when clicking on SAVE APPLY CHANGES During this time it will be unre sponsive The unit will beep once when it reboots and beep twice when it is ready 2 IP ADDRESS Default fallback IP addresses for the EZ Bridge are 192 168 1 139 and 192 168 1 239 To access the EZ Bridge control panel your computer IP addre...

Страница 8: ... The only reason you might want to set a fixed channel is if you experience interference from local wireless systems and you find a channel that works better To change the channel go to WIFI EDIT Device Config uration CHANNEL NOTE You only need to change the channel on the AP side The client will automatically follow after a few minutes 5 SITE SURVEY The site survey is a very useful tool to determ...

Страница 9: ...aults This action will also refresh the DHCP 8 FIRMWARE UPGRADE For the latest firmware point your browser to https support tyconsystems com Download the latest firmware to your PC Go to BACKUP FLASH FIRMWARE FLASH NEW FIRM WARE CHOOSE FILE and then browse for the new file then click FLASH IMAGE The update process takes about 4 minutes You will hear 1 beep when the unit reboots and two beeps when ...

Страница 10: ...ics will survive a direct strike but there are close proximity strikes that can cause huge electrical fields to be generated which can damage electronic equipment We have taken special care in the design of the EZ Bridge unit to ensure proper grounding of the electronics inside the enclosure to prevent damage from electrical storms Make sure that the POE Power Supply is plugged into a surge protec...

Страница 11: ... is down Reset both units to factory defaults and power cycle them If it cannot see the remote unit from the remote side bring the power supply and POE Inserter cable from the working side and see if that fixes the problem Also check your cables 2 Poor Performance If you are seeing poor performance power cycle both units then after about 10 minutes check the signal strength on the status page of t...

Страница 12: ... you would need to use a different network scanning tool like Advanced IP Scanner http www advanced ip scanner com The EZ Bridge antennas will show up as Compex Systems With MacOS you would need to right click on the discovery tool and select Open as MacOS usually blocks jar files from opening 4 EZ Bridge is not working or can t be discovered over the net work We test each pair of EZ Bridges befor...

Страница 13: ... second router on the remote receiving end make sure that the LAN port of side B s PoE inserter is connected to the LAN port of the router For a more detailed troubleshooting step by step procedure and check list please visit this page https tyconsystems com support view kb kbartid 24 Start up procedure flow chart can be found here https tyconsystems com support view faq faqid 104 NOTES ...

Страница 14: ... V 35 deg 20 deg Antenna Front to Back 20dB 25dB Polarization 2x2 MIMO 2x2 MIMO POE Specification Power Over Ethernet PoE Inserter 100 240VAC 50 60Hz 48VDC PoE 802 3af at bt or 48VDC Passive PoE Average Power Consumption 8W Mechanical Specifications Color White Dimensions L x W x H 12 4 x 7 3 x 2 5 314 x 187x 65mm System Weight 7 lb 3 kg Ethernet Connector RJ45 Mount Pole up to 2 dia or Wall Envir...

Страница 15: ...support up to 867Mbps so it is typically used as the point to point bridge function The 2 4GHz radio can support up to 400 Mbps and is typically used as a separate access point to provide wireless access at the local and or remote site or to connect to a third site The EZ Bridge AC comes with the 2 4GHz access point preconfig ured so it just needs to be enabled Follow these steps Note The two radi...

Страница 16: ...uired Next go to WIFI EDIT and set the ESSID on the antennas Avoid us ing spaces and special characters on the ESSID Just use simple ASCII characters like EZBRIDGE PAIR1 Both antennas in the pair must have the same ESSID As an Option you can also change the wireless security key on differ ent pairs of antennas You would go to WIFI EDIT WIRELESS SE CURITY to change the wireless security key Don t u...

Страница 17: ...17 Notes ...

Страница 18: ... circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or modifications not expressly ap proved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with Part 15 of the FCC Rules Operation is sub ject to the following two conditions 1 ...

Страница 19: ... the product to the origi nal purchaser For all other countries the original purchaser shall pay all shipping broker fees duties and taxes incurred in shipping products to and from Tycon Systems Provided the goods have not been modi fied or repair attempted by someone other than Tycon Systems at the option of Tycon Systems products may be returned either as repaired or replaced If it is determined...

Страница 20: ...20 8000081 Rev1 EZ Bridge AC Qwik Install Guide ...

Отзывы: