TFP410

Page 10 of 10 

Limited  

Warranty

Products manufactured by Tyco Fire 

Suppression  &  Building  Products 

(TFSBP)  are  warranted  solely  to  the 

original Buyer for ten (10) years against 

defects in material and workmanship 

when paid for and properly installed 

and  maintained  under  normal  use 

and service. This warranty will expire 

ten (10) years from date of shipment 

by  TFSBP.  No  warranty  is  given  for 

products  or  components  manufac-

tured  by  companies  not  affiliated  by 

ownership with TFSBP or for products 

and  components  which  have  been 

subject  to  misuse,  improper  instal-

lation,  corrosion,  or  which  have  not 

been  installed,  maintained,  modified 

or repaired in accordance with appli-

cable Standards of the National Fire 

Protection  Association,  and/or  the 

standards  of  any  other  Authorities 

Having Jurisdiction. Materials found by 

TFSBP to be defective shall be either 

repaired or replaced, at TFSBP’s sole 

option.  TFSBP  neither  assumes,  nor 

authorizes any person to assume for 

it, any other obligation in connection 

with the sale of products or parts of 

products. TFSBP shall not be respon-

sible for sprinkler system design errors 

or  inaccurate  or  incomplete  infor-

mation supplied by Buyer or Buyer’s 

representatives. 
In no event shall TFSBP be liable, in 

contract,  tort,  strict  liability  or  under 

any other legal theory, for incidental, 

indirect,  special  or  consequential 

damages, including but not limited to 

labor charges, regardless of whether 

TFSBP was informed about the possi-

bility  of  such  damages,  and  in  no 

event shall TFSBP’s liability exceed an 

amount equal to the sales price. 
The  foregoing  warranty  is  made  in 

lieu  of  any  and  all  other  warranties, 

express or implied, including warran-

ties of merchantability and fitness for a 

particular purpose.
This  limited  warranty  sets  forth  the 

exclusive  remedy  for  claims  based 

on  failure  of  or  defect  in  products, 

materials or components, whether the 

claim is made in contract, tort, strict 

liability or any other legal theory. 
This  warranty  will  apply  to  the  full 

extent permitted by law. The invalidity, 

in whole or part, of any portion of this 

warranty will not affect the remainder.

Ordering  

Procedure

Contact  your  local  distributor  for 

availability.  When  placing  an  order, 

indicate the full product name and Part 

Number (P/N).

Sprinkler Assembly

Specify  Series  LFII  Residential 

Horizontal Sidewall Sprinkler (TY1334), 

K=4.2,  with  (temperature  rating)  and  

(finish), and P/N (below).

155°F (68°C)

  Chrome Plated  . . . . . . . . . . . . P/N 51-211-9-155
155°F (68°C)

  White Polyester . . . . . . . . . . . . P/N 51-211-4-155
155°F (68°C) 

  White 

  (RAL9010)* . . . . . . . . . . . . . . . . P/N 51-211-3-155
155°F (68°C)

  Natural Brass . . . . . . . . . . . . . . .P/N 51-211-1-155
175°F (79°C) or 

  Chrome Plated  . . . . . . . . . . . . P/N 51-211-9-175
175°F (79°C)

  White Polyester . . . . . . . . . . . . P/N 51-211-4-175
175°F (79°C) 

  White 

  (RAL9010)* . . . . . . . . . . . . . . . . P/N 51-211-3-175
175°F (79°C)

  Natural Brass . . . . . . . . . . . . . . .P/N 51-211-1-175

*Eastern Hemisphere sales only. 

Recessed Escutcheon

Specify Style 20 Recessed Escutcheon 

with finish and P/N. Refer to Technical 

Data Sheet TFP770.

Sprinkler Wrench

Specify  W-Type  6  Sprinkler  Wrench, 

P/N 56-000-6-387.
Specify  W-Type  7  Sprinkler  Wrench, 

P/N 56-850-4-001.

Содержание TY1334

Страница 1: ...filled pipe in addition to not having to increase the number of design sprinklers hydraulic design area for systems designed to NFPA 13 13D or 13R Non water filled pipe will permit options for areas sensitive to freezing The Series LFII Residential Sprinklers has a 4 2 60 5 K Factor that provides the required residential flow rates at reduced pressures enabling smaller pipe sizes and water supply ...

Страница 2: ...ating Bulb Deflector 1 Components 2 Button Assembly Frame TOP 57 2 mm 2 1 4 41 3 mm 1 5 8 6 4 5 3 2 1 2 7 8 DIA 73 0 mm RECESSED ESCUTCHEON STYLE 20 FLATS WRENCH CENTERLINE OF WATERWAY 1 2 NPT BOSS END OF DEFLECTOR TOP OF DEFLECTOR 7 16 11 1 mm FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS TY1334 FIGURE 2 STYLE 20 RECESSED ESCUTCHEO...

Страница 3: ...sprinkler systems the requirements for Dry System Water Delivery per the Section 8 3 4 3 of the 2010 edition of NFPA 13D apply For a residential hazard in no case shall the time of water delivery exceed 15 seconds for the most remote operating sprinkler Hydraulic Design NFPA 13D and 13R The minimum re quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Tables A B C...

Страница 4: ...M 18 4 psi 1 27 bar 16 x 18 4 9 x 5 5 16 4 9 19 GPM 71 9 LPM 20 5 psi 1 41 bar 19 GPM 71 9 LPM 20 5 psi 1 41 bar 21 GPM 79 5 LPM 25 0 psi 1 72 bar 21 GPM 79 5 LPM 25 0 psi 1 72 bar 16 x 20 4 9 x 6 1 16 4 9 23 GPM 87 1 LPM 30 0 psi 2 07 bar 23 GPM 87 1 LPM 30 0 psi 2 07 bar 26 GPM 98 4 LPM 38 3 psi 2 64 bar 26 GPM 98 4 LPM 38 3 psi 2 64 bar Sidewall sprinklers where installed under a ceiling with a...

Страница 5: ... 4 9 23 GPM 87 1 LPM 30 0 psi 2 07 bar Not Applicable Not Applicable Not Applicable Sidewall sprinklers where installed under a ceiling with a slope greater than a 0 inch rise for a 12 inch run to a slope up to a 2 inch rise for a 12 inch run must be located per one of the following At the high positioned to discharge down the slope Along the slope and positioned to discharge across the slope a Fo...

Страница 6: ...7 bar I 14 GPM 53 0 LPM 11 1 psi 0 77 bar I 17 GPM 64 3 LPM 16 4 psi 1 13 bar I 17 GPM 64 3 LPM 16 4 psi 1 13 bar 16 x 16 4 9 x 4 9 16 4 9 I 16 GPM 60 6 LPM 14 5 psi 1 00 bar I 16 GPM 60 6 LPM 14 5 psi 1 00 bar I 18 GPM 68 1 LPM 18 4 psi 1 27 bar I 18 GPM 68 1 LPM 18 4 psi 1 27 bar 16 x 18 4 9 x 5 5 16 4 9 I 19 GPM 71 9 LPM 20 5 psi 1 41 bar I 19 GPM 71 9 LPM 20 5 psi 1 41 bar I 21 GPM 79 5 LPM 25...

Страница 7: ...LPM 18 4 psi 1 27 bar 14 x 14 4 3 x 4 3 14 4 3 II 16 GPM 60 6 LPM 14 5 psi 1 00 bar II 16 GPM 60 6 LPM 14 5 psi 1 00 bar II 18 GPM 68 1 LPM 18 4 psi 1 27 bar II 18 GPM 68 1 LPM 18 4 psi 1 27 bar 16 x 16 4 9 x 4 9 16 4 9 II 16 GPM 60 6 LPM 14 5 psi 1 00 bar II 16 GPM 60 6 LPM 14 5 psi 1 00 bar II 18 GPM 68 1 LPM 18 4 psi 1 27 bar II 18 GPM 68 1 LPM 18 4 psi 1 27 bar 16 x 18 4 9 x 5 5 16 4 9 II 22 G...

Страница 8: ... C 12 x 12 3 7 x 3 7 12 3 7 III 16 GPM 60 6 LPM 14 5 psi 1 00 bar III 16 GPM 60 6 LPM 14 5 psi 1 00 bar 14 x 14 4 3 x 4 3 14 4 3 III 16 GPM 60 6 LPM 14 5 psi 1 00 bar III 16 GPM 60 6 LPM 14 5 psi 1 00 bar 16 x 16 4 9 x 4 9 16 4 9 III 16 GPM 60 6 LPM 14 5 psi 1 00 bar III 16 GPM 60 6 LPM 14 5 psi 1 00 bar 16 x 18 4 9 x 5 5 16 4 9 N A N A 16 x 20 4 9 x 6 1 16 4 9 N A N A a For coverage area dimensio...

Страница 9: ...e Series LFII Residential Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling Care and Maintenance The RAPID RESPONSE Series LFII Residential Horizontal and Recessed Horizontal Sidewall Sprinklers TY1334 must be maintained and serviced in accordance with the following instructions NOTICE Before closing a fire protection system main control valv...

Страница 10: ...ncluding but not limited to labor charges regardless of whether TFSBP was informed about the possi bility of such damages and in no event shall TFSBP s liability exceed an amount equal to the sales price The foregoing warranty is made in lieu of any and all other warranties express or implied including warran ties of merchantability and fitness for a particular purpose This limited warranty sets f...

Отзывы: