Notes:

l

PIR beams can extend past the set range coverage distance if you direct the detector at an open space.

l

To calibrate the detector sensitivity to identify persons more accurately, set the detector detection range. For more information, see

Configuring the

detector parameters

.

l

To protect a window, mount the detector on an upper corner of the window frame so that the PIR beams are parallel with the glass pane.

3. Mounting the MP-902 PG2

To mount the MP-902 PG2, complete the following steps:

1.

Use the uppermost and middle holes in the device bracket to mark two holes in the mounting surface. See Hole Number 1 and Hole Number 2 in
Figure 4.

2.

Optional: To avail of tamper protection, use the bottommost hole in the break-away segment of the bracket to mark a third hole in the mounting
surface. See Hole Number 3 in Figure 4.

3.

Drill the required holes in the mounting surface according to the markings and insert the wall plugs. See Figure 5.

4.

Fasten the bracket to the mounting surface with screws. See Figure 6.

5.

Insert the batteries into the detector and close the battery cover. For more information, see

Inserting or replacing the batteries

.

6.

Insert the top of the detector into the bracket. As you insert the detector, choose a slot in the bracket that positions the detector to cover the area
that requires protection. See Figure 7 and Figure 8.

Note:

 When you complete Step 6, a blinking LED indicates the start of the tamper self-calibrating procedure.

Note:

When the detector is resting on the unscrewed bracket, it can be rotated freely to a more exact final position. See Hole Number 1 in Figure

9.

7.

While the LED is blinking, tighten the bottom screw to close the bracket. See number 2 in Figure 9.

Note:

If the yellow LED stops blinking before the screw is tightened adequately, remove the detector from the bracket and wait three seconds.

Repeat Step 6 to start the self-calibrating procedure.

Figure 4:

Marking the screw holes

Figure 5:

Drilling the screw holes

Figure 6:

Fastening the bracket

Figure 7:

Rotation slot

Figure 8: Slotting into the device

Figure 9:

Closing the bracket

D-307164 MP-902 PG2 Installation instructions

2

Содержание MP-902 PG2

Страница 1: ... 902 PG2 Before you install the device consider the following points l Install the MP 902 PG2 according to the Standard for Installation and Classification of Burglar and Holdup Alarm Systems UL 681 l Mount the detector so that the expected movement of the intruder will cross the PIR beam l Mount the device on a vertical surface and as straight as possible l Mount the device upright See Figure 2 l...

Страница 2: ...et to the mounting surface with screws See Figure 6 5 Insert the batteries into the detector and close the battery cover For more information see Inserting or replacing the batteries 6 Insert the top of the detector into the bracket As you insert the detector choose a slot in the bracket that positions the detector to cover the area that requires protection See Figure 7 and Figure 8 Note When you ...

Страница 3: ...ation instructions as described in Table 2 Table 2 Modifying the device Option Configuring instructions Alarm LED Activate or deactivate the alarm LED indication Optional settings LED ON default and LED OFF PIR range Select one of the three ranges according to your installation preference See Setting the detector range Outdoor anti mask Enable or disable the outdoor anti masking feature Optional s...

Страница 4: ...erts VERY HOT COLD FREEZING and FREEZER Table 3 describes the temperature configuration setting options Table 3 Temperature configuration settings Option Configuring instructions Threshold Displays the last saved threshold value To change the default value click the back or next button to decrease or increase the value and click OK Disable Enable Defines whether or not the panel will report an ale...

Страница 5: ... old batteries and insert the batteries with the and symbols matching the illustration found in the battery compartment See Number 2 in Figure 15 4 Optional To activate the batteries of a new device pull the battery tab while holding the batteries in place with your thumb See Figure 16 5 To close the battery compartment insert the bottom section of the battery cover first and then press and hold t...

Страница 6: ...d do not expect other pets or rodents to enter the protected area set the pet immunity selector to Setting 4 and mount the detector at a height of 1 6 m 5 25 ft to 2 m 6 56 ft The best mounting height for this setting is 2 m or 6 56 ft l If you have a small pet that weighs less than 3 kg or 6 6 lb or if there are rodents in the area set the pet immunity selector to Setting 2 and mount the detector...

Страница 7: ...llation guide l The MP 902 PG2 can be configured to detect movement with the following settings Left to right Right to left and Both For more information see the alarm direction setting in Modifying the device Table 5 Walk test signal strength indication LED response Reception 3 Green blinks Strong 3 Orange blinks Good 3 Red blinks Poor No blinks No communication 9 LED operation Table 6 provides t...

Страница 8: ...Pet configurations l Setting 1 Pet 18 kg or 40 lbs default l Setting 2 Small pet 3 kg or 6 6 lb or rodents l Setting 3 No function l Setting 4 No pet WIRELESS Frequency Europe and rest of world 433 434 MHz 868 869 MHz USA and Canada 912 919 MHz Note Only devices in frequency band 915 MHz are UL ULC listed Max Tx power 10 dBm 433 MHz 14 dBm 868 MHz Communication protocol PowerG Supervision Signals ...

Страница 9: ...urs de son fonctionnement normal Les antennes utilisées pour ce produit ne doivent pas être situés ou exploités conjointement avec une autre antenne ou transmetteur NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a resi...

Отзывы: