6. Inserting or replacing the batteries

Warning:

If you replace the batteries with an incorrect type, there is a risk of explosion.

Note:

 When you replace the batteries, wait one minute after the batteries are removed before you insert the new batteries.

To insert or replace the batteries, complete the following steps:

1.

Unscrew the bottom screw of the bracket and remove the detector. See Figure 12 and Figure 13.

2.

Press on the snap located at the top of the battery cover with your thumb to open the battery cover. See Figure 14.

3.

Optional: To replace the batteries, remove the old batteries and insert the batteries with the (+) and (-) symbols matching the illustration found in
the battery compartment. See Number 2 in Figure 15.

4.

Optional: To activate the batteries of a new device, pull the battery tab while holding the batteries in place with your thumb. See Figure 16.

5.

To close the battery compartment, insert the bottom section of the battery cover first and then press and hold the snap while closing the top part of
the cover. See Number 1 and Number 2 in Figure 17.

6.

Insert the device into the bracket and tighten the bottom screw of the bracket. For more information, see Step 6 and Step 7 in

Mounting the MP-

902 PG2

Note:

 Dispose of used batteries according to the manufacturer instructions and according to local rules and regulations.

Figure 12: Unscrewing the bracket

Figure 13: Removing the detector from bracket

D-307164 MP-902 PG2 Installation instructions

5

Содержание MP-902 PG2

Страница 1: ... 902 PG2 Before you install the device consider the following points l Install the MP 902 PG2 according to the Standard for Installation and Classification of Burglar and Holdup Alarm Systems UL 681 l Mount the detector so that the expected movement of the intruder will cross the PIR beam l Mount the device on a vertical surface and as straight as possible l Mount the device upright See Figure 2 l...

Страница 2: ...et to the mounting surface with screws See Figure 6 5 Insert the batteries into the detector and close the battery cover For more information see Inserting or replacing the batteries 6 Insert the top of the detector into the bracket As you insert the detector choose a slot in the bracket that positions the detector to cover the area that requires protection See Figure 7 and Figure 8 Note When you ...

Страница 3: ...ation instructions as described in Table 2 Table 2 Modifying the device Option Configuring instructions Alarm LED Activate or deactivate the alarm LED indication Optional settings LED ON default and LED OFF PIR range Select one of the three ranges according to your installation preference See Setting the detector range Outdoor anti mask Enable or disable the outdoor anti masking feature Optional s...

Страница 4: ...erts VERY HOT COLD FREEZING and FREEZER Table 3 describes the temperature configuration setting options Table 3 Temperature configuration settings Option Configuring instructions Threshold Displays the last saved threshold value To change the default value click the back or next button to decrease or increase the value and click OK Disable Enable Defines whether or not the panel will report an ale...

Страница 5: ... old batteries and insert the batteries with the and symbols matching the illustration found in the battery compartment See Number 2 in Figure 15 4 Optional To activate the batteries of a new device pull the battery tab while holding the batteries in place with your thumb See Figure 16 5 To close the battery compartment insert the bottom section of the battery cover first and then press and hold t...

Страница 6: ...d do not expect other pets or rodents to enter the protected area set the pet immunity selector to Setting 4 and mount the detector at a height of 1 6 m 5 25 ft to 2 m 6 56 ft The best mounting height for this setting is 2 m or 6 56 ft l If you have a small pet that weighs less than 3 kg or 6 6 lb or if there are rodents in the area set the pet immunity selector to Setting 2 and mount the detector...

Страница 7: ...llation guide l The MP 902 PG2 can be configured to detect movement with the following settings Left to right Right to left and Both For more information see the alarm direction setting in Modifying the device Table 5 Walk test signal strength indication LED response Reception 3 Green blinks Strong 3 Orange blinks Good 3 Red blinks Poor No blinks No communication 9 LED operation Table 6 provides t...

Страница 8: ...Pet configurations l Setting 1 Pet 18 kg or 40 lbs default l Setting 2 Small pet 3 kg or 6 6 lb or rodents l Setting 3 No function l Setting 4 No pet WIRELESS Frequency Europe and rest of world 433 434 MHz 868 869 MHz USA and Canada 912 919 MHz Note Only devices in frequency band 915 MHz are UL ULC listed Max Tx power 10 dBm 433 MHz 14 dBm 868 MHz Communication protocol PowerG Supervision Signals ...

Страница 9: ...urs de son fonctionnement normal Les antennes utilisées pour ce produit ne doivent pas être situés ou exploités conjointement avec une autre antenne ou transmetteur NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a resi...

Отзывы: