  This  product  is  suitable  for  use  in  systems  installed  to 

conform  to  PD6662:2010  at  Grade  2  and  environmental 
class 2. DD243 and BS8243

 

USA:

 CFR 47 part 15 

Canada:

 RSS 210  

RFID Tags:

 ISO-18000-2 (125 kHz) 

The Power G peripheral devices have two- way communication functionality, providing additional benefits as 
described in the technical brochure. This functionality has not been tested to comply with the respective 
technical requirements and should therefore be considered outside the scope of the product’s certification

 

EN 50131-1 Security Grade 

According to EN 50131-1:2006 and A1:2009, this equipment 
can be applied in installed systems up to and including 
Security Grade 2 

EN 50131-1 Environmental Class 

Class II 

 

This device complies with FCC Rules Part 15 and Industry Canada license-exempt RSS standard(s). 
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this 
device must accept any interference, including interference that may cause undesired operation of the 
device. 

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de 
licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de 
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le 
brouillage est susceptible d'en compromettre le fonctionnement. 

WARNING

! To comply with FCC and IC RF exposure compliance requirements, the mobile version of this 

device should be located at a distance of at least 20 cm from all persons during normal operation. The antennas 
used for this product must not be co-located or operated in conjunction with any other antenna or transmitter. 

The portable device version complies with FCC and IC RF radiation exposure limits set forth for an uncontrolled 
environment.

 

The digital circuit of this device has been tested and found to comply with the limits for a Class B digital device, 
pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection  against 
harmful  interference  in  residential  installations.  This  equipment  generates,  uses,  and  can  radiate  radio 
frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the  instructions,  may  cause  harmful 
interference to radio and television reception. However, there is no guarantee that interference will not occur in 
a particular installation. If this device does cause such interference, which can be verified by turning the device 
off and on, the user is encouraged to eliminate the interference by one or more of the following measures: 
– Re-orient or re-locate the receiving antenna. 
– Increase the distance between the device and the receiver. 
– Connect the device to an outlet on a circuit different from the one which supplies power to the receiver. 
– Consult the dealer or an experienced radio/TV technician. 
Changes or modifications not expressly approved by Visonic Ltd. could void the user's authority to operate the 
equipment. 

 

W.E.E.E. Product Recycling Declaration

 

For  information regarding the recycling  of this product  you must contact the  company from 
which  you  orignially  purchased  it.  If  you  are  discarding  this  product  and  not  returning  it  for 
repair  then  you must  ensure  that  it is  returned  as  identified  by  your  supplier. This  product is 
not to be thrown away with everyday waste. 

Directive 2002/96/EC Waste Electrical and Electronic Equipment.

 

 

 

 

 

 

 

 

Содержание DSC WK160

Страница 1: ...ng Options 4 2 4 Enrolling the WK160 6 2 5 Configuring the WK160 Parameters 6 2 6 Enrolling Proximity Tags 8 3 USING THE TOUCH SCREEN KEYPROX 9 3 1 Arming and Disarming the System 9 3 2 Initiating Ala...

Страница 2: ...e WK160 can be wall mounted using the supplied bracket or be used as a portable unit For compliance with various international standards the WK160 is equipped with two tamper switches that can be defi...

Страница 3: ...incorrect type Dispose of used battery according to manufacturer s instructions Figure 1 Battery Insertion Insert two 1 5V batteries in each slot while ensuring battery polarity 2 2 Closing Battery C...

Страница 4: ...Mounting part b A Tamper B DC Power Connection 2 3 Wall Mounting Options The WK160 unit mounting options are illustrated in the following drawings Wall Mounting Figure 4a Wall Mounting 1 Drill 3 moun...

Страница 5: ...Mounting with External Electrical Connector Figure 4b Wall Mounting with External Electrical Connector 1 Secure bracket with 2 screws as shown in the two drawings above 2 Attach the unit to the bracke...

Страница 6: ...ready enrolled you can configure the WK160 parameters via the Modify Devices option see Step 2 2 5 Configuring the WK160 Parameters Enter the main menu in the WP8010 30 control panel choose the number...

Страница 7: ...Note For UL Listed product set to ON Define the volume level of the sounder Option settings Medium default Maximum and Minimum Note For UL Listed product the sounder cannot be used as the only annunci...

Страница 8: ...h the WP8010 30 control panel as described in the corresponding section of the control panel s User or Installer Guide Each proximity tag corresponds to its User Code Therefore be sure that a correspo...

Страница 9: ...enabled 2 sec Optional 4 INSTANT After arming HOME AWAY 5 7 LATCHKEY After arming AWAY 6 7 Notes 1 If Partition is disabled at the control panel skip Step 1 2 If Partition is enabled at the control p...

Страница 10: ...conds the WK160 sends the command Fire alarm 2 sec See section 3 3 Panic alarm 2 sec See section 3 3 When pressing the Fire and Emergency icons together the WK160 starts beeping After pressing the but...

Страница 11: ...on indication is displayed concurrently with the second partition key LED and then the third partition indication is similarly displayed General Indications The Ready Not Ready Alarm Memory Trouble an...

Страница 12: ...ion system has an active trouble status that needs to be reviewed and cleared 3 AC failure Communication failure WK160 is out of range of the control panel or did not get an acknowledge signal of a co...

Страница 13: ...s that are assigned to a Partition press the desired Partition number followed by the key Upon each press of the key the next zone number assigned to the pressed Partition number appears on the Zone d...

Страница 14: ...X 10 output functions see the corresponding sections of the control panel s Installer Guide OUTPUTS menu and User Guide SCHEDULER menu Step X 10 device ON PGM device ON X 10 or PGM device OFF X 10 or...

Страница 15: ...Low Battery Threshold 3 8 V Power source optional 5 12VDC Back light Blue white or black white Operating Temperature 0 C to 55 C 32 F to 131 F Note For UL Listed product the ambient temperature is 32...

Страница 16: ...operation The antennas used for this product must not be co located or operated in conjunction with any other antenna or transmitter The portable device version complies with FCC and IC RF radiation...

Страница 17: ...ge mechanical shock water damage or damage arising out of abuse alteration or improper application of the equipment Digital Security Controls DSC warrants that for a period of 12 months from the date...

Страница 18: ...18 D 306042 WK160 User s Guide 2016 Tyco International Ltd and its Respective Companies All Rights Reserved Toronto Canada www dsc com Printed in Israel D 306042 Rev 01 02 16...

Отзывы: