©1997 Central Sprinkler Company
Printed in U.S.A.
A1 Adj. Dry.3
Ordering Information: When
placing an order, indicate the full
product name. Please specify the
quantity, model, style, orifice size,
temperature rating, sprinkler finish,
and escutcheon finish, and required
“C” Dimension.
See page 2 for “C” Dimension
information.
For special painted concealed
plate finishes, the customer must
supply a quick-drying paint, a
lacquer-base is preferred, to insure
proper color duplication.
Availability and Service: Central
sprinklers, valves, accessories and
other products are available through-
out the U.S. and Canada, and
internationally, through a network of
Central Sprinkler distribution centers.
You may write directly to Central
Sprinkler Company, or call (215)
362-0700 for the distributor nearest
you.
Patents: Patents are pending.
Conversion Table:
1 inch = 25.400 mm
1 foot = 0.3048 M
1 pound = 0.4536 kg
1 foot pound = 1.36 Nm
1 psi = 6.895 kpa
= 0.0689 bar
= 0.0703 kg/cm
2
1 U.S. gallon = 3.785 dm
3
= 3.785 liters
Conversions are approximate.
Ordering
Information
obstructions must be removed. In the
event that construction has altered
the original configuration, additional
sprinklers should be installed to
maintain the protection level.
Do not attempt to replace sprinklers
without first removing the fire protec-
tion system from service. Be certain
to secure permission from all
Authori-
ties Having Jurisdiction, and notify all
personnel who may be affected
during system shutdown. A fire
watch during maintenance periods is
a recommended precaution.
To remove the system from service,
first refer to the system operating
guide and valve instruction. Drain
water and relieve pressure in the
pipes. Remove the existing unit and
install the replacement, using only the
recommended sprinkler wrench. Be
certain to match model, style, orifice,
and temperature rating.
A fire protection system that has
been shut off after an activation
should be repaired and returned to
service immediately. Inspect the
entire system for damage and replace
or repair as necessary. Sprinklers
that did not operate but were sub-
jected to corrosive elements of
combustion or excessive tempera-
tures should be inspected, and
replaced if need be. The
Authority
Having Jurisdiction will detail mini-
mum replacement requirements and
regulations.
Guarantee: Central Sprinkler
Company will repair and/or replace
any products found to be defective in
material or workmanship within a
period of one year from the date of
shipment. Please refer to the current
Price List for further details of the
warranty.
Care &
Maintenance
Sprinklers must be handled care-
fully. They must not be transported
or stored where ambient temperature
may exceed 100
°
F/38
°
C. For best
results, store them in a dry, cool
location in the original shipping
package.
Do not install sprinklers that have
been dropped or visibly damaged.
Sprinklers should never be painted,
coated, plated or altered in any other
way from manufactured condition or
they may not function properly. Any
sprinklers altered in such a manner
must be replaced.
The owner is responsible for the
proper operating condition of all fire
protection devices and accessories.
The NFPA standard 25 entitled,
“Inspection, Testing and Maintenance
of Water-Based Fire Protection
Systems”, contains guidelines and
minimum maintenance requirements.
Furthermore, the local
Authority
Having Jurisdiction may have addi-
tional regulations and requirements
for maintenance, testing, and inspec-
tion that must be obeyed.
It is advisable to have sprinkler
systems inspected regularly by a
qualified inspection service. Length
of time between such inspections can
vary due to accessibility, ambient
atmosphere, water supply, and site
activity.
Do not attempt to reassemble or
otherwise reuse a sprinkler that has
operated. Replace any sprinkler
exhibiting corrosion or damage;
always use new sprinklers of the
same orifice, style, and temperature
rating as replacements.
Because the discharge pattern is
critical to protection of life and
property, nothing should be hung or
attached to the sprinkler unit that
would disrupt the pattern. Such
Central Sprinkler Company
451 North Cannon Avenue, Lansdale, PA 19446
Phone: 215-362-0700
FAX: 215-362-5385
OBSOLETE