2
Dimensions (in mm)
Closure Type
GCO2-BC6-XX
GCO2-BD6-XX
GCO2-BE6-XX
L
488
566
700
D with clamp
285
285
285
Closure Type
GCO2-BC6-XX
GCO2-BD6-XX
GCO2-BE6-XX
Capacity
Primary coated fibers
Single element
336
480
672*
Single circuit 2
112
160
224
Single circuit 4
224
320
448
Ribbon 4
2 ribbons each tray
40 (160 fibercount) 80 (320)
110 (440)
1 ribbon each tray
20 (80 fibercount)
40 (320)
55 (220)
Ribbon 12
1 ribbon each tray
16 (192 fibercount) 28 (336)
36 (432)
* Capacity on FAS can depend on capacity on tubeholder, see for instance the
capacity table for loose tubes later on
According network layout and cable constructions the kit content can
be different from the kit content described in this installation
instruction.
•
Dome
•
Base including routing block + cover (universal mounting system),
shield mounting bolt, and strength member termination bracket
•
Clamp
•
O-ring
•
100g Silicagel
•
2 tray fiber guiding pin +tube holder retainers
•
2 tray wedges
•
Installation Instruction
2
General
2.1
Abbreviations
Looped Cable Installation Tool
LCIT
Universal Mounting System
UMS
2.2
Kit contents
Cable diameters in 6 port base
Loose tube loop, 12-25mm
drop,(5-30mm)
C.Core
loop, 12-25mm
drop,(5-25mm)
Cable diameters in 16 port base
Loose tube loop, 12-25mm
drop ports 3-10,(5-20mm)
drop ports 11-18,(5-14mm)
C.Core
loop, 12-25mm
drop ports 3-10,(5-20mm)
drop ports 11-18,(5-14mm)