19
5.2
Round port
5.2.1
Repeat all the steps as discribed in oval port.
5.3
16 port base
5.3.1
It is recommended to use the hingable workstand.
Note
: use the appropriate seals for the ports.
Fibers can be routed between OS1, OS2, ES1 and ES2. In case that
fibers have to be routed from SIDE-O (Odd portnumbers) to SIDE-E
(Even portnumbers), use the window (see picture). Select the cable
termination as such, that a minimum of fibers will cross and have to be
routed through the window. Therefore the selection of the ports
according to the cable lay-out is important.
6
Fiber routing
6 PORT BASE
: Ports (1+3), (6+8) for cables to (S2). Ports (5+7), (2+4)
for cables to (S1). Verify the position of two cables if they are placed on
the same side (next to each other) because the total amount of loose
tubes in ports (1+3) or (2+4) or (5+7) or (6+8) can never be more than
mentioned in the capacity of the tube holder.
S1 side
S2 side
To E or
O side