409-5880
Programmer Kit 356484-1 for FFC Terminating Machines 224910-[ ] and 318619-[ ]
Rev B
8 of 13
Tyco Electronics Corporation
Figure 7
Main Menu
Activate
PartNumber
to Run (Production)
Edit
PartNumber
View
PartNumber
Enter
PartNumber
to Edit
Delete
PartNumber
View
PartNumber
Increment
to Next
PartNumber
Select
PartNumber
PartNumber
Information
(Data)
Memory
PartNumber
Information
(Data)
Select
PartNumber
Save
PartNumber
Review
PartNumbers
Discard
PartNumber
Select
Increment
to Next
PartNumber
Sequence of Operations
Enter the part number or press the F3 (VIEW) key to view the parts in memory. Pressing the F3 function key in
the select part mode results in the screen shown in Figure 8.
Pressing the F4 (MENU) key returns the operator to the main menu.
Figure 8
P/N (First P/N in Memory)
F1 = NEXT
F3 = SELECT
F2 = DATA
F4 = MENU
5.3. View Part
When the operator presses the F3 (VIEW) key from the main menu, the control module will begin to show each
of the parts currently stored in memory. The parts are presented in increasing order by part number, and the
operator views the next part by pressing the F1 (NEXT) key. Pressing F2 (DATA) one or more times displays
additional data about the part being examined. The first time that the F2 key is pressed, the total number of
cable conductors is displayed. The next time that the F2 key is pressed, the position of the first conductor to be
skipped is displayed. Each subsequent pressing of F2 displays the next conductor to be skipped.