background image

409-5880

Programmer Kit 356484-1 for FFC Terminating Machines 224910-[ ] and 318619-[ ]

Rev B

10 of 13

Tyco Electronics Corporation

Figure 11

ENTER P/N
P/N = (Part Number to Create)

F4 = MENU

2. Enter the part number (up to four digits) and enter the total number of conductors in the cable. See
Figure 12. Press ENTER. Pressing ENTER will result in the screen in Figure 13.

3. Press F1 (YES) if positions are to be skipped, or F2 (NO) if positions are 

not to be skipped. See

Figure 13. If F1 is pressed, type each position to be skipped (Figure 14) and press ENTER after each.

The conductor closest to the operator (as it is installed in the FFC terminating machine) is in the first position.

Figure 12

P/N = (Part Number to be Entered)
ENTER # OF POSITIONS

F4 = MENU

Figure 13

P/N = (Part Number to be Entered)
ANY POSITIONS SKIPPED?

F2 = NO
F4 = MENU

F1 = YES

Figure 14

P/N = (Part Number to be Entered)
SKIP POSITIONS = ________

F3 = DONE

NOTE

i

Содержание 356484-1

Страница 1: ...o change For latest revision and Regional Customer Service visit our website at www tycoelectronics com 28 JUL 08 Rev B 224910 and 318619 1 INTRODUCTION 3 2 DESCRIPTION 2 1 Physical Description 4 2 2...

Страница 2: ...atch in moving parts of the application equipment D NEVER insert hands into installed application equipment D NEVER alter modify or misuse the application equipment TOOLING ASSISTANCE CENTER CALL TOLL...

Страница 3: ...flat cable with the FFC terminating machine The control module must be located adjacent to the FFC terminating machine within easy reach of the operator The control module which is connected to the ma...

Страница 4: ...elayed to the operator through a display window on the control panel The control module is operated through a keypad on the front panel of the control module This keypad includes two directional keys...

Страница 5: ...item 21 and install the count switch assembly item 3 onto the switch bracket item 22 with screws item 10 Secure the assemblies to locations on the rear plate with screws item 27 and washers item 31 S...

Страница 6: ...Mounting Screw Horizontal with Center of Main Shaft Ref Cam Mount Count Switch Assembly Reset and Count Switch Adjustments 21 Screw 3 10 Screw Switch Bracket 22 23 10 24 211 4 Figure 4 Strip Block Gu...

Страница 7: ...e screws after the solenoid is properly adjusted If additional adjustment is required shorten the pull rod slightly by bending it 5 SEQUENCE OF OPERATION Each time the control module is turned on the...

Страница 8: ...the select part mode results in the screen shown in Figure 8 Pressing the F4 MENU key returns the operator to the main menu Figure 8 P N First P N in Memory F1 NEXT F3 SELECT F2 DATA F4 MENU 5 3 View...

Страница 9: ...p the first position the operator will be required to hit the F1 SET SKIP key before depressing the START button on the FFC Terminating Machine This process must be repeated for every cable run After...

Страница 10: ...Figure 13 3 Press F1 YES if positions are to be skipped or F2 NO if positions are not to be skipped See Figure 13 If F1 is pressed type each position to be skipped Figure 14 and press ENTER after eac...

Страница 11: ...e format that an individual part is displayed in the view parts mode See Figure 15 Figure 15 P N Part Number Being Entered F2 NO F1 YES F3 REVIEW 5 Press function key F1 DONE when finished reviewing o...

Страница 12: ...be between 0 and 65520 EPROM ERROR This indicates that the nonvolatile memory may be damaged Attempt the action again If the error recurs the EPROM needs to be replaced Contact your local Representati...

Страница 13: ...Test Displays all the pixels addressing and commands associated with the display If the F1 key is pressed repeatedly the control module displays all characters by filling one half of the screen at a...