66
Target Temp.
If current temp. > Target Temp. + Tolerance, increase fan speed. If current
temp. < Target Temp. – Tolerance, decrease fan speed.
Fan Temp. Tolerance
If current temp. > Target Temp. + Tolerance, increase fan speed. If current
temp. < Target Temp. – Tolerance, decrease fan speed.
Start-up Fan Output
FAN Speed will increase from 0 to this value to provide a minimum value to turn
on the fan.
•
Disabled
• Enabled
Max. Fan Output
When at SMART FANTM III mode, Fan Speed will increase to this value.
Min. Fan Output
If the temp. keeps below low limit, then the fan speed keeps on decreasing until
Stop Value.