background image

 

http://www.tyan.com 

138 

3.4.1     BMC Network Configuration Submenu

 

 

 

 

Содержание S7120

Страница 1: ...crosoft Corporation Winbond is a trademark of Winbond Electronics Corporation Notice Information contained in this document is furnished by MiTAC International Corporation and has been reviewed for accuracy and reliability prior to printing MiTAC assumes no liability whatsoever and disclaims any express or implied warranty relating to sale and or use of TYAN products including liability or warrant...

Страница 2: ...stalling Motherboard in Chassis 28 2 8 Installing the Memory 30 2 9 Attaching Drive Cables 34 2 10 Installing Add In Cards 35 2 11 Connecting External Devices 36 2 12 Installing the Power Supply 38 2 13 Finishing Up 38 Chapter 3 BIOS Setup 39 3 1 About the BIOS 39 3 2 Main Menu 41 3 3 Advanced Menu 43 3 4 Server Management 136 3 5 Security 140 3 6 Boot 145 3 7 Save Exit 148 Chapter 4 Diagnostics 1...

Страница 3: ...er x 2 1 x S7120 Quick Installation Guide M 2 Screw kit x2 IMPORTANT NOTE 1 Sales samples may not come with any of the accessories listed above If you have ordered a sales sample and you are missing any of the above items please contact your sales representative to help order accessories 2 The standard rear I O shielding listed in the above packing contain does not support RJ45 OCP Accessories ...

Страница 4: ...e the S7120 with the power and flexibility to meet demanding requirements for today s IT environments Remember to visit the TYAN website at http www tyan com There you can find all the information on all TYAN products as well as all the supporting documentation FAQs Drivers and BIOS upgrades 1 2 Hardware Specifications S7120GM2NRE Specifications Processor Q ty Socket Type 2 LGA4189 Supported CPU S...

Страница 5: ...00 Chipset Aspeed AST2600 Input Output Others 1 ID button USB 2 USB3 0 ports rear COM 2 headers VGA 1 D Sub 15 pin VGA port rear RJ 45 2 GbE ports 1 GbE dedicated for IPMI Front Panel 1 2x12 pin SSI front panel header SATA 3 Mini SAS HD from PCH SATA III Power SSI 24 pin 8 pin 8 pin power connectors TPM Optional TPM Support Please refer to our TPM supported list System Monitoring Chipset Aspeed AS...

Страница 6: ...LAN Storage User Configurable FAN PWM Duty Cycle Console Redirection ACPI sleeping states S4 S5 ACPI 6 1 Physical Dimension Form Factor SSI EEB compatible Board Dimension 12 2 x 13 04 309 8 x 331 2mm Regulation FCC DoC Class A CE DoC Class A RCM Class A VCCI Class A Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90 non con...

Страница 7: ...S 3200 Capacity Up to 1 024GB RDIMM 2 048GB LRDIMM 2 048GB RDIMM 3DS LRDIMM 3DS Follow latest Intel DDR4 Memory POR Memory channel 8 Channels per CPU Memory voltage 1 2V Expansion Slots PCI E 2 PCI E Gen4 x8 3 PCI E Gen4 x16 LAN Q ty Port 2 10GbE ports 1 dedicated for IPMI Controller Intel X550 PHY Realtek RTL8211E Storage SATA Connector 3 Mini SAS 12 ports 2 SATA totally support 14 ports Controll...

Страница 8: ...r temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2600 AST2500 iKVM Feature 24 bit high quality video compression Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2500 IPMI Feature IPMI 2 0 compliant baseboard management controller BMC 10 100 1000 Mb s MAC interface BIOS Brand ROM si...

Страница 9: ...6 6 Compliant Yes Operating System OS supported list Please refer to our AVL support lists Package Contains Motherboard 1 S7120 Motherboard Manual 1 Quick Installation Guide I O Shield 1 I O Shield Cable SATA 2 SATA signal cables 1 3 Software Specifications For the latest AST2600 User s Guide and OS operation system support please visit the Tyan s Web site at http www tyan com for the latest infor...

Страница 10: ...conditions MiTAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the motherboard components IC chips connectors memory modules and leads 4 Place the motherboard on a grounded antistatic surface or on the antistatic bag that the board was shipped in 5 Inspect the board for damag...

Страница 11: ...http www tyan com 11 2 1 Board Image S7120GM2NRE ...

Страница 12: ...http www tyan com 12 S7120GM2NRE 2T This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above picture ...

Страница 13: ...http www tyan com 13 2 2 Block Diagram S7120 Block Diagram ...

Страница 14: ...http www tyan com 14 2 3 Motherboard Mechanical Drawing ...

Страница 15: ...sion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM population guidelines shown later in the manual For the latest board revision please visit our web site at http www tyan com ...

Страница 16: ...YS_FAN_2 13 TYAN Module Header DBG_HD1 33 SlimSAS Connector for HDD BP SlimSAS2 14 Fan Tachometer Header FAN_HD1 34 CPU Fan CPU0_FAN 15 SD Socket J21 35 PSMI Connector J14 16 Power Button PWR_BTN1 36 System Fan SYS_FAN_1 17 NVMe Hot plug Header J17 37 Power Connector for CPU0 J15 18 NVMe Hot plug Header J8 38 PSU Connector J6 19 Reset Button RST_BTN1 39 Power Connector for CPU1 J16 20 Clear Button...

Страница 17: ...SYS_Air_Inlet 21 22 LAN1_LED_P FP_NMI_BTN_N 23 24 LAN1_LED_N HD_COM1 2 COM Port Connector Signal Pin Pin Signal COM_DCD 1 2 COM_DSR COM_RXD 3 4 COM_RTS COM_TXD 5 6 COM_CTS COM_DTR 7 8 COM_NRI GND 9 10 KEY FAN_HD1 FAN PWM Header Signal Pin Pin Signal TACH1 1 2 TACH6 TACH2 3 4 TACH7 TACH3 5 6 TACH8 TACH4 7 8 TACH9 TACH5 9 10 TACH10 GND 11 12 KEY PWM2 13 14 PWM1 TACH11 15 16 SMB_DATA TACH12 17 18 SMB...

Страница 18: ... TPM_ADDR_MB 15 16 PCH_TPM_PP_EN J23 Front USB3 0 Header Signal Pin Pin Signal 5V 1 2 P0_RX_N P0_RX_P 3 4 GND P0_TX_N 5 6 P0_TX_P GND 7 8 P0_N P0_P 9 10 OC_N P1_P 11 12 P1_N GND 13 14 P1_TX_P P1_TX_N 15 16 GND P1_RX_P 17 18 P1_RX_N 5V 19 20 Key CPU0 1 FAN SYS FAN1 4 4 pin CPU Fan Connector Pin 1 2 3 4 Signal GND VCC12 FAN_TACH PWM Use this header to connect the cooling fan to your motherboard to k...

Страница 19: ...VGA_B GND 9 10 HD_VGA_DAT VGA_HD_HS 11 12 KEY VGA_HD_CLK 13 14 HD_VGA_VS SSATA4 SSATA5 sSerial Advanced Technology Attachment Gen3 sSATA 7 1 Name TYPE S1 GND S2 SATA TX DP S3 SATA TX DN S4 GND S5 SATA RX DN S6 SATA RX DP S7 GND Connects to the Serial ATA ready drives via the Serial ATA cable ID LED_BTN1 Rear IO IDLED Button Signal Pin Pin Signal FP_IDLED_BTN_N 1 2 GND J51 PCH_SATA_RAID_KEY HW Key ...

Страница 20: ...set Button for clear CMOS Pin 1 2 3 4 Signal GND GND RST_N RST_N PWR_BTN1 POWER Button Pin 1 2 3 4 Signal GND GND PWR_BTN1 PWR_BTN1 RST_BTN1 Reset Button Pin 1 2 3 4 Signal GND GND FP_RST_BTN_N FP_RST_BTN_N J113 ME Recovery Mode Jumper Pin 1 2 3 Signal NC FM_ME_RCVR_N GND Pin 1 2 Closed Normal Mode Default Pin 2 3 Closed ME In Force Update Mode ...

Страница 21: ... Default Pin2 3 Closed BMC Debug Port J35 BMC COM Port TX debug Jumper Signal Pin Pin Signal BMC_COM2_TXD 1 2 TXD_2 BMC_COM5_TXD 3 Pin1 2 Closed BMC COM2 Port Default Pin2 3 Closed BMC Debug Port J12 LPC eSPI Mode Jumper Signal Pin Pin Signal GND 1 2 ESPI_H_LPC_L P3V3_AUX 3 Pin1 2 Closed LPC Mode Default Pin2 3 Closed ESPI Mode J34 FP Reset Mode Signal Pin Pin Signal RST_BTN_N 1 2 FP_RST_BTN_N FP_...

Страница 22: ...IN A4 SATA6G_RX_P1 SATA6G_RX_N1 PIN A5 PIN A6 GND SATA6G_RX_P3 PIN A7 PIN A8 SATA6G_RX_N3 GND PIN A9 PIN B1 GND SGPIO _LOAD PIN B2 PIN B3 GND SATA6G_RX_P0 PIN B4 PIN B5 SATA6G_RX_N0 GND PIN B6 PIN B7 SATA6G_RX_P2 SATA6G_RX_N2 PIN B8 PIN B9 GND SGPIO_SATA_DATAO UT0 PIN C1 PIN C2 GND GND PIN C3 PIN C4 SATA6G_TX_P1 SATA6G_TX_N1 PIN C5 PIN C6 GND SATA6G_TX_P3 PIN C7 PIN C8 SATA6G_TX_N3 GND PIN C9 PIN ...

Страница 23: ...http www tyan com 23 2 5 LED Definitions ...

Страница 24: ...Beat LED Pin Signal P3V3_AUX GND State Description OFF OFF The LED shuts off when the PCH ME is not work or properly initiated Blinking Green The LED blinks per second to indicate that the PCH ME is working normally CPUPWR _LED CPU PWOK LED Pin Signal P3V3_AUX GND State Description OFF OFF The LED shuts off when the power of CPU is abnormal ON Green The LED lights up when the power of CPU is norma...

Страница 25: ...stall the processors and heat sinks Please note that the illustrations are based on LGA4189 socket which may not look exactly like the motherboard you purchased Therefore the illustrations should be held for your reference only NOTE Please save and replace the flip CPU protection cap when returning for service 1 Align the triangle edge of the carrier with the notch on the edge of the heatsink Then...

Страница 26: ...ng an alcohol solvent Then apply new thermal grease before reinstalling the heatsink 3 Remove the CPU cover 4 Carefully flip the heatsink assembly Align the heatsink with the CPU socket by the guide pins Make also sure that the triangle edge of the carrier is aligned correctly with the triangle mark on the CPU socket Then place the heatsink assembly onto the top of the CPU socket ...

Страница 27: ...ure the gold arrow is located in the correct direction Then place the heatsink onto the top of the CPU socket 6 To secure the heatsink use a Security T30 Security Torx to tighten the screws in a sequential order 1 2 3 4 When dissembling the heatsink loosen the screws in reverse order 4 3 2 1 ...

Страница 28: ...t simply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard will not be able to be securely installed Note Be especially careful to look for extra stand offs If there are any stand offs present that are not aligned with a mounting hole on the motherboard it wi...

Страница 29: ...ead of metal Although the plastic studs are usable MiTAC recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common motherboard studs look like and how they should be installed ...

Страница 30: ...ction All memory must be of the same type and density Different memory types can NOT be mixed and matched on the same motherboard General Population Requirements DIMM Mixing Rules All DIMMs must be either all DDR4 DIMMs and or DDR4 and Barlow Pass DIMMs Mixing of RDIMMs and LRDIMMs is not allowed in the same channel across different channels and across different sockets Mixing of Barlow Pass DIMMs...

Страница 31: ... 1 indicates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM 4 Always install with CPU0 Socket first ...

Страница 32: ...0 P0_MC2_DIM_CH_F0 P0_MC3_DIM_CH_G0 P0_MC3_DIM_CH_H1 Dual CPU Installed CPU0 and CPU1 Quantity of memory installed 2 4 6 8 10 12 14 16 P0_MC0_DIM_CH_A0 NOT Re commended NOT Re commended NOT Re commended P0_MC0_DIM_CH_B0 P0_MC1_DIM_CH_C0 P0_MC1_DIM_CH_D0 P0_MC2_DIM_CH_E0 P0_MC2_DIM_CH_F0 P0_MC3_DIM_CH_G0 P0_MC3_DIM_CH_H1 P1_MC0_DIM_CH_A0 P1_MC0_DIM_CH_B0 P1_MC1_DIM_CH_C0 P1_MC1_DIM_CH_D0 P1_MC2_DIM...

Страница 33: ...lock a DIMM socket by Press the retaining clip outwardly in the following illustration 2 Align the memory module with the socket such that the DIMM NOTCH match the KEY SLOT on the socket 3 Seat the module firmly into the socket by gently pressing down until it sits flush with the socket The locking levers pop up into place ...

Страница 34: ...http www tyan com 34 2 9 Attaching Drive Cables Attaching SAS Power Cable Attaching Mini SAS HD Cable Attaching SATA Cable ...

Страница 35: ...f CPU0 Simply find the appropriate slot for your add in card and insert the card firmly Do not force any add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and the add in card TIP It s a good practice to install add in cards in a staggered manner rather than making them directly adjacent to e...

Страница 36: ...ont or rear ID button for 5 seconds it will perform the same behavior as pressing the system power button to power on or off the system The implementation is convenient to onsite service technicians that need to press the power button when he she is at the rear side of the system Please visit https www tyan com Motherboards S7120 S7120GM2NR L2 downloads EN to download the latest BMC firmware relea...

Страница 37: ...F Active Blinking Green OFF 100 Mbps Link Green Solid Green Active Blinking Green Solid Green 1Gbps Link Green Solid Amber Active Blinking Green Solid Amber 10Gbps LAN Port LAN Indication X550 10 100 1000 Mbps LAN Link Activity LED Scheme Left LED Link Activity Right LED Speed No Link OFF OFF 100 Mbps Link Solid Green Solid Green Active Blinking Green Solid Green 1000 Mbps Link Solid Green Solid A...

Страница 38: ...tor Signal Pin Pin Signal GND 1 5 P1_P12V GND 2 6 P1_P12V GND 3 7 P1_MEM_P12V GND 4 8 P1_MEM_P12V 2 13 Finishing Up Congratulations on making it this far You have finished setting up the hardware aspect of your computer Before closing up your chassis make sure that all cables and wires are connected properly especially SATA cables and most importantly jumpers You may have difficulty powering on yo...

Страница 39: ... to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are then stored in a dedicated battery backed memory called NVRAM that retains the information even when the power is turned off To start the BIOS setup utility 1 Turn on or reboot your system 2 Press F2...

Страница 40: ...seemingly small change to the Chipset setup options may cause the system to become unstable or unusable 3 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic look and function of the BIOS setup remains more or less the same for most systems the appearance of your Setup screen may differ from the charts shown in this section Each system design and chipset...

Страница 41: ... for options that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Platform Information It displays Platform information Memory Information This displays the total memory size System Language Choose the system default language System Date Adjust the system date MM Months DD Days YYYY Years ...

Страница 42: ...http www tyan com 42 System Time Adjust the system clock HH 24 hours format MM Minutes SS Seconds ...

Страница 43: ...ons for your system Option ROM Dispatch Policy Option ROM Dispatch Policy S5 RTC Wake Settings S5 RTC Wake Settings Trusted Computing Trusted Computing settings ACPI Settings System ACPI Parameters Power Management Power Management Serial Port Console Redirection Serial Port Console Redirection ...

Страница 44: ...able Option ROM execution setting etc NVMe Configuration NVMe Device Options Settings Onboard Device Configuration Onboard Device and Function Configuration Network Stack Configuration Network Stack Settings Hardware Health Configuration Hardware Health Configuration NVDIMM ADR Configuration NVDIMM ADR Configuration CPU Registration This item support INTEL CPU sign the CPU will record current CPU ...

Страница 45: ...uration Configure the iSCSI parameters Intel R Ethernet Converged Network Adapter X550 T2 Configure 10 Gigabit Ethernet device parameters Intel R Ethernet Converged Network Adapter X550 T2 Configure 10 Gigabit Ethernet device parameters Driver Health Provides Health Status for the Drivers Controllers ...

Страница 46: ...oard Mass Storage Controller Onboard Device has UEFI X Legacy X Embedded ROM s VIDx8086 DIOxA1D2 s0 Bx0 Dx11 Fx5 Disabled Enabled On Board Mass Storage Controller Onboard Device has UEFI X Legacy X Embedded ROM s VIDx8086 DIDxA182 s0 Bx0 Dx17 Fx0 Disabled Enabled ...

Страница 47: ... X Legacy X Embedded ROM s VIDx8086 DID x1563 s0 Bx31 Dx0 Fx1 Disabled Enabled Slot 1 Empty Enable or Disable Option ROM execution for selected Slot Disabled Enabled Slot 2 Empty Enable or Disable Option ROM execution for selected Slot Disabled Enabled Slot 3 Empty Enable or Disable Option ROM execution for selected Slot Disabled Enabled Slot 4 Empty Enable or Disable Option ROM execution for sele...

Страница 48: ...d Slot Disabled Enabled Slot 8 Empty Enable or Disable Option ROM execution for selected Slot Disabled Enabled Slot 9 Empty Enable or Disable Option ROM execution for selected Slot Disabled Enabled Slot 10 Empty Enable or Disable Option ROM execution for selected Slot Disabled Enabled Slot 11 Empty Enable or Disable Option ROM execution for selected Slot Disabled Enabled ...

Страница 49: ...ww tyan com 49 3 3 2 S5 RTC Wake Settings RTC Wake system from S4 S5 Enable or disable system wake on alarm event When enabled System will wake on the day hr min sec specified Disable Fixed Time Dynamic Time ...

Страница 50: ... com 50 3 3 3 Trusted Computing Security Device Support Enable or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available Enable Disable ...

Страница 51: ...Enable ACPI Auto Configuration Enable or disable BIOS ACPI Auto Configuration Disabled Enabled Enable Hibernation Enables or disables System ability to Hibernate OS S4 Sleep State This option may not be effective with some OS Disabled Enabled ...

Страница 52: ...http www tyan com 52 3 3 5 Power Management Configuration CPU Power and Performance Policy CPU Power and Performance Policy Performance Balanced Power Power ...

Страница 53: ...ole Redirection Settings Serial Port for Out Of Band Management Windows Emergency Services EMS Console Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the host computer which the user is using will exchange data Both computers should have the same or compatible settings NOTE Console Redirection Settings menu only appear when ...

Страница 54: ...ial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 9600 19200 38400 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with the data bits to detect some transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even Odd parity bit is 0 if the num of 1 s in the data bits is odd Mark parity bit is always 1...

Страница 55: ...t to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode With this mode enabled only text will be sent This is to capture Terminal data Disabled Enabled...

Страница 56: ...ial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 9600 19200 38400 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with the data bits to detect some transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even Odd parity bit is 0 if the num of 1 s in the data bits is odd Mark parity bit is always 1...

Страница 57: ...t to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode With this mode enabled only text will be sent This is to capture Terminal data Disabled Enabled...

Страница 58: ...Resolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST When Bootloader is selected then legacy Console Redirection is disabled before booting to legacy OS When always Enable is selected then Legacy Console Redirection is enabled for legacy OS Default setting for this option is set to Always Enable Always Enable BootLoader ...

Страница 59: ...rough a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Settings page for more Help with Terminal Type Emulation VT UTF8 VT100 VT100 ANSI Bits per Second EMS Select serial port transmission speed The speed must be matched on the other side Long or noisy lines may requ...

Страница 60: ...e Xon Xoff Data Bits EMS Parity EMS Stop Bits EMS Read only 3 3 7 PCI Subsystem Settings Above 4G Decoding Enables or Disables 64bit capable Devices to be decoded in Above 4G Address Space Only if System supports 64 bit PCI Decoding Enable Disable SR IOV Support If system has SR IOV capable PCIe devices this option Enable or Disable Single root IO virtualization Support Enabled Disabled BME DMA Mi...

Страница 61: ...ge the Common RefCode Settings Uncore Configuration Displays and provides option to change the Uncore Settings Memory Configuration Displays and provides option to change the Memory Settings IIO Configuration Displays and provides option to change the IIO Settings Advanced Power Management Configuration Displays and provides option to change the Power Management Settings ...

Страница 62: ...http www tyan com 62 3 3 8 1 Processor Configuration Submenu ...

Страница 63: ...t 0 Disabled Enabled L2 RFO Prefetch Disable L2 RFO Prefetch MSR 972h Bit 3 Disable Enable Adjacent Cache Prefetch MLC Spatial Prefetcher MSR 1A4h Bit 1 Disabled Enabled Extended APIC Enable disable extended APIC support Disabled Enabled APIC Physical Mode Enable Disable the APIC physical destination mode Disabled Enabled Enable Intel R TXT Enables Intel R TXT Disabled Enabled Intel R Virtualizati...

Страница 64: ...le PPIN Control Lock Disable Unlock Enable AES NI Enable disable AES NI support Disabled Enabled TSC Reset Enable or Disable TSC reset during warm reboot Disabled Enabled RDT CAT Opportunistic Tuning Cache Allocation Technology mask tuning options NOTE If IOT is enabled on any socket this option will override to 0x003 Default 0x7FF Tuned 0x600 Tuned 0x003 Tuned 0x700 ...

Страница 65: ...High Granularity Size Selects the allocation size used to assign mmioh resources Total mmioh space can be up to 32x granularity Per stack mmioh resource assignments are multiples of the granularity where 1 unit Per stack is the default allocation 1G 4G 16G 64G 256G 1024G Numa Enable or Disable non uniform Memory Access NUMA Enabled Disabled ...

Страница 66: ...http www tyan com 66 3 3 8 3 Uncore General Configuration Submenu Uncore General Configuration Displays and provides option to change the Uncore General Settings ...

Страница 67: ...lt speed Slow Slow Fast Link Frequency Select Allows for selecting the UPI Link frequency 9 6GB s 10 4GB s 11 2GB s Auto Use Per Link Setting Link L0p Enable Enable Set the c_L0p_en Disable Reset it Auto Auto decides based on Si Compatibility Disable Enable Auto Link L1 Enable Enable Set the c_L1_en Disable Reset it Auto Auto decides based on Si Compatibility Disable Enable Auto ...

Страница 68: ...http www tyan com 68 UPI Failover Support Enable Set the c_failover_en Disable Reset it Auto Auto decides based on Si Compatibility Disable Enable Auto 3 3 8 3 1 1 Uncore Status Configuration Submenu ...

Страница 69: ...it to the MRC default setting current default is Enable Enforce POR Disable Halt on mem Training Error Halt on mem training Error Disable Enable Disable Enable Attempt Fast Boot Enable Portions of memory reference code will be skipped when possible to increase boot speed on warm boots Disable Disables this feature Auto Sets it to the MRC default setting current default is Disable Disable Enable ...

Страница 70: ...the MRC default setting current default is Disable Disable Enable RMT On Cold Fast Boot Enable Enables Rank Margin Tool on Cold Fast Boot Disable Disables this feature Auto Sets it to the MRC default setting current default is Disable Should be disabled in production release Disable Enable Rank Margin Tool Enable Enables the legacy rank margin tool to run after DDR4 memory training Disable Disable...

Страница 71: ...paring is enabled partial mirroring will not take effect Enabling any type of Mirror Mode will disable Disable Full Mirror Mode Partial Mirror Mode Mirror TAD0 Enable Mirror on entire memory for TAD0 Disabled Enabled UEFI ARM Mirror Imitate behavior of UEFI based Address Range Mirror with setup option Disabled Enabled Correctable Error Threshold Correctable Error Threshold 0x01 0x7fff used for spa...

Страница 72: ...the number of hours 1 24 required to complete full scrub A value of zero means auto 24 3 3 8 5 IIO Configuration Socket0 Configuration Socket 0 Configuration Socket1 Configuration Socket 1 Configuration Intel VT for Directed I O VT d Press Enter to bring up the Intel VT for Directed I O VT d Configuration menu Intel VMD technology ...

Страница 73: ...up the Intel AIC Retimer AIC SSD Configuration menu Retimer workaround Enable or disable the retime workaround No yes PCIe Hot Plug Enable Disable PCIe Hot Plug globally No yes PCIe ACPI Hot Plug Enable Disable PCIe ACPI Hot Plug globally or allow per port control When Disabled MSI is generated on HP event When Enabled _ HPGPE message is generated No yes Per individual port ...

Страница 74: ...urcation for selected slot s x4x4x4x4 X4x4x8 x8x4x4 x8x8 x16 Auto IOU2 IIO PCIe Port 3 Selects PCIe port Bifurcation for selected slot s x4x4x4x4 X4x4x8 x8x4x4 x8x8 x16 Auto IOU3 IIO PCIe Port 4 Selects PCIe port Bifurcation for selected slot s x4x4x4x4 X4x4x8 x8x4x4 x8x8 x16 Auto IOU4 IIO PCIe Port 5 Selects PCIe port Bifurcation for selected slot s x4x4x4x4 X4x4x8 x8x4x4 x8x8 x16 Auto Port 1A ...

Страница 75: ...Port 2B Settings related to PCI Express Ports 0 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D 5A 5B 5C 5D Port 2C Settings related to PCI Express Ports 0 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D 5A 5B 5C 5D Port 4A Settings related to PCI Express Ports 0 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D 5A 5B 5C 5D Port 5A Settings related to PCI Express Ports 0 1A 1B 1C 1D 2A 2B 2C 2D 3A 3...

Страница 76: ...t and expose hide its CFG space Disable Enable Auto Link Speed Choose Link Speed for this PCIe port Auto Gen 1 2 5 GT s Gen 2 5GT s Gen 3 8 GT s Gen 4 16GT s Override Max Link Width Override the max link width that was set by bifurcation Auto x1 x2 x4 x8 x16 PCIE Port DeEmphasis De Emphais control LNKCON2 6 for this PCIe port 3 5 dB 6 0dB PCI E ASPM Support This option enables disables ASPM L1 sup...

Страница 77: ...t1 Submenu IOU0 IIO PCIe Port 1 Select PCIe port Bifurcation for selected slot s x4x4x4x4 X4x4x8 x8x4x4 x8x8 x16 Auto IOU1 IIO PCIe Port 2 Selects PCIe port Bifurcation for selected slot s x4x4x4x4 X4x4x8 x8x4x4 x8x8 x16 Auto IOU2 IIO PCIe Port 3 Selects PCIe port Bifurcation for selected slot s x4x4x4x4 X4x4x8 x8x4x4 x8x8 x16 Auto IOU3 IIO PCIe Port 4 ...

Страница 78: ...A 4B 4C 4D 5A 5B 5C 5D Port 2A Settings related to PCI Express Ports 0 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D 5A 5B 5C 5D Port 4A Settings related to PCI Express Ports 0 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D 5A 5B 5C 5D Port 5A Settings related to PCI Express Ports 0 1A 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D 4A 4B 4C 4D 5A 5B 5C 5D Port 5C Settings related to PCI Express Ports 0 1A 1B...

Страница 79: ...TFORM _OPT_IN _FLAG in DMAR table in ACPI Not compatible with Direct Device Assignment DDA Disabled Enabled Interrupt Remapping Enable Disable VT_D Interrupt Remapping Support Auto Enable Disable X2APIC Opt Out Enable Disable X2APIC_OPT_OUT bit Disabled Enabled Pre boot DMA protection Enable DMA protection in Pre boot environment If DMAR table is installed in DXE and If VTD_INFO_PPI is installed i...

Страница 80: ...http www tyan com 80 3 3 8 5 4 Intel VMD for Volume Management Device on Socket 0 1 Submenu ...

Страница 81: ...http www tyan com 81 VMD Config for PCH ports VMD Config for IOU 0 1 2 3 4 Enable Disable VMD in this Stack Disabled Enabled 3 3 8 5 5 Intel AIC Retimer AIC SSD Technology non VMD Configuration ...

Страница 82: ...http www tyan com 82 3 3 8 5 5 1 Intel AIC Retimer AIC SSD on Socket 0 1 ...

Страница 83: ...Ux bifurcation if required Disabled Enabled Intel AIC Retimer AIC SSD HW at Stack3 Announce Intel AIC Retimer AIC SSD HW at Stack3 Port3A 3D Override IOUx bifurcation if required Disabled Enabled Intel AIC Retimer AIC SSD HW at Stack4 Announce Intel AIC Retimer AIC SSD HW at Stack4 Port4A 4D Override IOUx bifurcation if required Disabled Enabled Intel AIC Retimer AIC SSD HW at Stack5 Announce Inte...

Страница 84: ...nfiguration Pcode Dispatcher Watchdog Timer Enable disable Pcode Dispatcher Watchdog Timer Disabled Enabled Auto CPU P State Control P State Control Configuration Sub Menu include Turbo XE and etc CPU C State Control CPU C State setting 3 3 8 6 1 CPU P State Control Submenu ...

Страница 85: ...PP Intel SST PP Select allows user to choose from up to two additional base frequency conditions Base Config 3 Config 4 Energy Efficient Turbo Energy Efficient Turbo Disable MSR 0x1FC 19 Disabled Enabled Turbo Mode Enable Disable processor Turbo Mode requires EMTTM enabled too Disabled Enabled Perf P Limit Enable Disable Performance P Limit Disabled Enabled ...

Страница 86: ...e limit C0 C1 state C2 state C6 non Retention state C6 Retention state Auto CPU C6 report Enable Disable CPU C6 ACPI C3 report to OS Auto Enable Disable Enhanced Halt State C1E Enables the Enhanced C1E state of the CPU takes effect after reboot Enabled Disabled 3 3 9 Memory Topology Submenu ...

Страница 87: ...http www tyan com 87 3 3 10 Memory Topology Submenu ...

Страница 88: ...http www tyan com 88 3 3 11 SATA Configuration Submenu ...

Страница 89: ...http www tyan com 89 SATA Configuration SATA devices and settings sSATA Configuration sSATA device and settings 3 3 11 1 SATA Configuration Submenu ...

Страница 90: ...SATA port is connected to Solid State Drive or Hard Disk Drive AHCI RAID SATA test Mode Enable Disable SATA test Mode Disabled Enabled SATA Mode options SATA mode related options Support Aggressive Link Power Management Enable Disables SALP Disabled Enabled SATA Port 0 1 2 3 4 5 6 7 Port 0 1 2 3 4 5 6 7 Disabled Enabled ...

Страница 91: ... Disabled Enabled Spin Up Device AHCI Supports Staggered Spin up Disabled Enabled SATA Device Type Indentify the SATA port is connected to Solid State Drive or Hard Disk Drive Hard Disk Drive Solid State Drive 3 3 11 1 1 SATA Mode options Configuration SATA HDD Unlock Enable HDD password unlock is enabled in the OS Disabled Enabled SATA LED locate ...

Страница 92: ...isable SATA Controller Disabled Enabled Configure sSATA as Identify the SATA port is connected to Solid State Drive or Hard Disk Drive AHCI RAID sSATA test mode Enable Disable sSATA test mode Disabled Enabled sSATA Port 0 1 2 3 4 5 Enable or Disable SATA Port Disabled Enabled Hot Plug Designates this port as Hot Pluggable Disabled Enabled ...

Страница 93: ...h have this option enabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled sSATA Device Type Indentify the SATA port is connected to Solid State Drive or Hard Disk Drive Hard Disk Drive Solid State Drive sSATA Topology Identify the Secondary SATA Topology if it is Default or ISATA or Flex or DirectConnect or M2 Unknown ISATA Direct Connect Flex M2 3 3 12 PCH Configuratio...

Страница 94: ...Express Configuration PCI Express Configuration settings SATA Configuration SATA devices and settings sSATA Configuration sSATA devices and settings USB Configuration USB Configuration Settings ADR Configuration Automatic DIMM Refresh ADR Configuration 3 3 12 1 PCH Devices Configuration ...

Страница 95: ...http www tyan com 95 Restore AC Power Loss Select S0 S5 for ACPI state after a G3 Power On Power Off Last State 3 3 12 2 PCI Express Configuration ...

Страница 96: ...yan com 96 PCI Express Root Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 PCI Express Root Port Settings 3 3 12 2 1 PCI Express Root Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Configuration ...

Страница 97: ... the PCI Express Root Port Disabled Enabled L1 Substates PCI Express L1 Substates settings Disable L1 1 L1 2 L1 1 L1 2 PCIe Speed PCI Express Root Port Completion Timer TO settings Auto Gen1 Gen2 Gen3 Max Payload Size PCIE Max Payload Size Selection MPL 128B MPL 256B 3 3 12 3 SATA Configuration Submenu ...

Страница 98: ...http www tyan com 98 SATA Controller Enable or Disable SATA Controller Disabled Enabled ...

Страница 99: ...ement Enable Disables SALP SATA Port 0 1 2 3 4 5 6 7 Port 0 1 2 3 4 5 6 7 Disabled Enabled Hot Plug Enable Disable SATA Ports Hot Plug Support Disabled Enabled Configure as eSATA Configures port as External SATA eSATA Disabled Enabled Spin Up Device AHCI Supports Staggered Spin up Disabled Enabled SATA Device Type Identify the SATA port is connected to Solid State Drive or Hard Disk Drive Hard Dis...

Страница 100: ...ww tyan com 100 SATA HDD Unlock Enable HDD password unlock is enabled in the OS Disabled Enabled SATA LED locate If enabled LED SGPIO hardware is attached Disabled Enabled 3 3 12 4 sSATA Configuration Submenu ...

Страница 101: ...http www tyan com 101 sSATA Controller Enable or Disable SATA Controller Disabled Enabled ...

Страница 102: ...Hot Pluggable Disabled Enabled Configure as eSATA Configures port as External SATA eSATA Disabled Enabled Spin Up Device If enabled for any of ports Staggerred Spin Up will be performed and only the drives witch have this option enabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled sSATA Device Type Indentify the SATA port is connected to Solid State Drive or Hard Disk...

Страница 103: ... XHCI Idle L1 Enabled XHCI Idle L1 Disabled to work around USB3 hot plug will fail after 1 hot plug removal Please put the system to G3 for the new settings to take effect Disable Enabled 3 3 12 6 ADR Configuration Submenu ...

Страница 104: ... GPIO C Host Partition Reset ADR Enable Enables Disables ADR on Host Partition Reset Platform POR Disable Enabled Enable Disable ADR Timer Held off for DEBUG PURPOSES ONLY Platform POR Disable Enabled ADR timer expire time Select proper ADR timer value 25uS 50uS 100uS or 0 Platform POR 25uS 50uS 100uS 0uS ADR timer multiplier Select proper ADR timer multiplier x1 8 24 40 56 64 72 80 88 96 Platform...

Страница 105: ...http www tyan com 105 3 3 13 Miscellaneous Configuration Submenu Active Video Select active Video type Auto Onboard Device PCIE Device 3 3 14 USB Configuration ...

Страница 106: ...e Driver Support Disabled Enabled Port 60 64 Emulation Enable I O port 60h 64h emulation support This should be enabled for the complete USB keyboard legacy support for non USB aware OSes Disabled Enabled USB transfer time out The time out value for Control Bulk and Interrupt transfers 20 sec 10 sec 5 sec 1 sec Device reset time out USB mass storage device Start Unit command time out 20 sec 10 sec...

Страница 107: ...uto Manual 3 3 13 CSM Configuration CSM support Enable Disable CSM Support Enabled Disabled Option ROM Messages Set display mode for Option ROM Force BIOS Keep Current Network Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Storage Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Video Controls the execution of UEFI and legacy PXE OpROM Do...

Страница 108: ...http www tyan com 108 Other PCI devices Determines OpRom execution policy for devices other than network storage or video legacy UEFI 3 3 14 NVMe Configuration ...

Страница 109: ...led Disabled Onboard LAN 1 X550 LAN Enable Disable control function Enabled Disabled External Clock General 9FGL08 Spread Spectrum Turn on off Spread Spectrum Setting for IsCLK Disabled Enabled Chassis Intrusion Detection Enabled When a chassis open event is detected the BIOS will display the event Disabled Enabled NMI Button Enable or disable NMI button Disabled Enabled ...

Страница 110: ...http www tyan com 110 3 3 16 Network Stack Configuration Network Stack Enable Disable UEFI Network Stack Disabled Enabled ...

Страница 111: ...trol Auto Fan Control help Full speed Manual NOTE Auto Fan Control must be set to Manual PWM Minimal Duty Cycle menu will appear PWM Minimal Duty Cycle PWM Minimal Duty Cycle 30 BMC Alert Beep Enable Disable BMC Alert Beep On Off PMBus support PMBus Support Disabled Enabled ...

Страница 112: ... 112 3 3 17 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE 1 SDR cannot be modified Read only ...

Страница 113: ...http www tyan com 113 ...

Страница 114: ...http www tyan com 114 ...

Страница 115: ... ADR Enables the detecting and enabling of ADR This is not available if eADR is enabled since eADR requires ADR to be enabled Enabled Disabled Assert ADR on Reset Assert ADR on Reset Disabled Enabled Assert ADR on Shutdown Assert ADR on Shutdown Disabled Enabled ...

Страница 116: ...stration Configuration Sign Up the current CPU This item support INTEL CPU sign the CPU will record current CPU Once BIOS checked different with registered CPU show WARNING message on POST screen Deregistration Sign Up Keep Current Status ...

Страница 117: ...emory Registration Configuration Sign Up the current Memory Sign the Memory will record current Memory Once BIOS checked different with registered Memory show WARNING message on POST screen Deregistration Sign Up Keep Current Status ...

Страница 118: ...http www tyan com 118 3 3 21 Tls Auth Configuration Submenu Sever CA Configuration Press Enter to configure Server CA ...

Страница 119: ...http www tyan com 119 3 3 21 1 Server CA Configuration Submenu Enroll Cert Press Enter to enroll cert Delete Cert Press Enter to delete cert ...

Страница 120: ... Configuration Submenu Enroll Cert Using File Enroll Cert Using File Cert GUID Input digit character in 11111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Commit Changes and Exit Discard Changes and Exit Discard Changes and Exit ...

Страница 121: ...http www tyan com 121 3 3 21 1 2 Delete Cert Submenu XXXXXXX XXXX XXXX XXXX XXXXXXXXXXXX GUID for CERT Enabled Disabled ...

Страница 122: ... 3 22 iSCSI Configuration Attempt Priority Chang the priority using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Host iSCSI Configuration Host iSCSI Configuration ...

Страница 123: ...rity Configuration Attempt Priority Change the Priority using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Host Attempt Redfish Attempt Commit Changes and Exit Commit Changes and Exit ...

Страница 124: ...tiate the iSCSI function Step 1 Select Advanced CSM Configuration Network UEFI Step 2 Select Advanced Network Stack Configuration Network Stack Enabled Step 3 Save changes and reboot iSCSI Initiator Name The worldwide unique name of iSCSI Initiator Only IQM format is accepted Range is from 4 to 223 ...

Страница 125: ...http www tyan com 125 3 3 22 2 1 Add an Attempt Read only ...

Страница 126: ... assigned in IP6 mode In Autoconfigure mode iSCSI driver will attempt to connect iSCSI target via IPv4 stack if failed then attempt IPv6 stack IPv4 IPv6 Autoconfigure Connection Retry Count The minimum value is 0 and the maximum is 16 0 means no retry Connection Establishing Timeout The timeout value in milliseconds The minimum value is 100 milliseconds and the maximum is 20 seconds ...

Страница 127: ... Gateway Enter IP address in dotted decimal notation Target Name The worldwide unique name of the target Only iqn format is accepted Range is from 4 to 223 iqu xxx Target Address Enter Target address in IPv4 IPv6 or URL format You need to configure DNS server address in advance if input a URL string Target Port Target Port Boot LUN Hexadecimal representation of the LU number Examples are 4752 3A4F...

Страница 128: ... assigned in IP6 mode In Autoconfigure mode iSCSI driver will attempt to connect iSCSI target via IPv4 stack if failed then attempt IPv6 stack IPv4 IPv6 Autoconfigure Connection Retry Count The minimum value is 0 and the maximum is 16 0 means no retry Connection Establishing Timeout The timeout value in milliseconds The minimum value is 100 milliseconds and the maximum is 20 seconds ...

Страница 129: ... Gateway Enter IP address in dotted decimal notation Target Name The worldwide unique name of the target Only iqn format is accepted Range is from 4 to 223 iqu xxx Target Address Enter Target address in IPv4 IPv6 or URL format You need to configure DNS server address in advance if input a URL string Target Port Target Port Boot LUN Hexadecimal representation of the LU number Examples are 4752 3A4F...

Страница 130: ...IPv4 Disabled Enabled Attempt 2 MAC 36 02 0B 83 D7 63 PFA Bus 35 Dev 0 Func 3 iSCSI mode Disabled IP version IPv4 Disabled Enabled Attempt 3 MAC 36 02 0B 83 D7 63 PFA Bus 35 Dev 0 Func 3 iSCSI mode Disabled IP version IPv4 Disabled Enabled Commit Changes and Exit Commit Changes and Exit Discard Changes and Exit Discard Changes and Exit ...

Страница 131: ...der Change the order of Attempts using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Attempt 1 Attempt 2 Attempt 3 Commit Changes and Exit Commit Changes and Exit Discard Changes and Exit Discard Changes and Exit ...

Страница 132: ...http www tyan com 132 3 3 23 Intel Ethernet Converged Network Adapter X550 T2 A0 42 3F 48 DB 18 ...

Страница 133: ...ion Wake On LAN Enables power on of the system via LAN Note that configuring Wake on LAN in the operating system does not change the value of this setting but does override the behavior of Wake on LAN in OS controlled power states Disabled Enabled ...

Страница 134: ...http www tyan com 134 3 3 24 Intel Ethernet Converged Network Adapter X550 T2 A0 42 3F 48 DB 19 ...

Страница 135: ...ion Wake On LAN Enables power on of the system via LAN Note that configuring Wake on LAN in the operating system does not change the value of this setting but does override the behavior of Wake on LAN in OS controlled power states Disabled Enabled ...

Страница 136: ...e Type of Interface to communicate BMC from HOSY Kcs Interface Bt Interface Wait For BMC Wait For BMC response for specified time out In PILOTII BMC starts at the same time when BIOS starts during AC power ON It takes around 30 seconds to initialize Host to BMC interface Disabled Enabled BMC Logo Enable or Disable BMC logo Disabled Enabled ...

Страница 137: ...arts a BIOS timer which can only be shut off by management Software after the OS loads Helps determine that the OS successfully loaded or follows the OS Boot Watchdog Timer policy Disabled Enabled NOTE When OS Watchdog Timer is set to Enabled the following items will be available OS Wtd Timer Timeout Configure the length of the OS Boot Watchdog Timer Not available if OS Boot Watchdog Timer is disa...

Страница 138: ...http www tyan com 138 3 4 1 BMC Network Configuration Submenu ...

Страница 139: ...ynamicBmcNonDhcp Management Port 2 Enable Disable BMC Share NIC Disabled Enabled Configuration Address Source Select the configure LAN channel parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Management Port 1 IPV6 Support Enable or Disable LAN1 IPV6 Support Disabl...

Страница 140: ...ord Set Administrator Password User Password Set User Password Security Frozen Mode Enable or disable HDD security freeze lock Disable to support secure erase function For AHCI SATA ports only Disabled Enabled Secure Boot Customizable Secure Boot settings ...

Страница 141: ...platform reset Disabled Enabled Secure Boot Mode Secure Boot mode selector Custom mode enables users to change Image execution policy and manage secure boot keys Standard Custom Restore Factory Keys Force System to User Mode Install factory default Secure Boot Key databases Reset To Setup Mode Delete all Secure Boot key databases from NVRAM Key Management Enables experienced users to modify Secure...

Страница 142: ... Keys Force System to User Mode Install factory default Secure Boot key databases Reset To Setup Mode Delete all Secure Boot key database from NVRAM Export Secure Boot variables Copy NVRAM content of Secure Boot variables to files in a root folder on a file system device Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 hash of the binary into Authorized Signature Database ...

Страница 143: ...t New Key Exchange Keys Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test Authorized Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certi...

Страница 144: ...Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test OsRecovery Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_S...

Страница 145: ...5 0xFFFF means indefinite waiting Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Endless Boot Enabled or Disabled Endless boot Disabled Enabled Wait for ESC if Error Wait for ESC stop when BIOS has error appeared Disabled Enabled ...

Страница 146: ...http www tyan com 146 Boot Option Priorities Boot Option 1 Sets the system boot order Device Name Disabled Delete Boot Option Remove an EFI boot option from the boot order ...

Страница 147: ...http www tyan com 147 3 6 1 Delete Boot Option Configuration Delete Boot Option Sets the system boot order Device Name Select one to Delete ...

Страница 148: ...g any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of the setup options Discard Changes Discard changes done so far to any of the setup options Restore Defaults Restore Load Default values for all the setup options ...

Страница 149: ...http www tyan com 149 Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Boot Override Device Name ...

Страница 150: ... 4 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard please check the TYAN web site at http www tyan com NOTE Please be aware that by flashing your BIOS you agree that in the event of a BIOS flash failure you must contact your dealer for a replacement BI...

Страница 151: ... 0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Note used Progress Codes 0x01 Power on Reset type detection soft hard 0x02 AP initialization before microcode loading 0x03 North Bridge initialization before microcode loading 0x04 South Bridge initialization b...

Страница 152: ...ation North Bridge module specific 0x19 Pre memory South Bridge initialization is started 0x1A Pre Memory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initialization South Bridge module specific 0x1C Pre Memory South Bridge initialization South Bridge module specific 0x1D 0x2A OEM pre memory initialization codes 0x2B Memory initialization Serial Presence De...

Страница 153: ...module specific 0x3F 0x4E OEM post memory initialization codes 0x4F DXE PIL is started PCI Error Codes 0x50 Memory initialization error Invalid memory type or incompatible memory speed 0x51 Memory initialization error SPD reading has failed 0x52 Memory initialization error Invalid memory size or memory modules do not match 0x53 Memory initialization error No usable memory detected 0x54 Unspecified...

Страница 154: ...loaded 0xF5 0xF7 Reserved for future AMI progress codes Recovery Error Codes 0xF8 Recovery PPI is not available 0xF9 Recovery capsule is not found 0xFA Invalid recovery capsule 0xFB 0xFF Reserved for future AMI error codes PEI Beep Codes of Beeps Description Progress Codes 1 Memory not installed 1 Memory was installed twice installPEIMemory routine in PEI Core called twice 2 Recovery started 3 DXE...

Страница 155: ...alization is started 0x71 South Bridge DXE SMM initialization is started 0x72 South Bridge devices initialization 0x73 South Bridge DXE initialization South Bridge module specific 0x74 South Bridge DXE initialization South Bridge module specific 0x75 South Bridge DXE initialization South Bridge module specific 0x76 South Bridge DXE initialization South Bridge module specific 0x77 South Bridge DXE ...

Страница 156: ...us Codes section below 0xAD Ready To Boot event 0xAE Legacy Boot event 0xAF Exit Boot Services event 0xB0 Runtime Set Virtual Address MAP Begin 0xB1 Runtime Set Virtual Address MAP End 0xB2 Legacy Option ROM initialization 0xB3 System Reset 0xB4 USB hot plug 0xB5 PCI bus hot plug 0xB6 Clean up of NVRAM 0xB7 Configuration Reset reset of NVRAM settings 0xB8 0xBF Reserved for future AMI codes 0xC0 0x...

Страница 157: ...t Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource requirements cannot be met ACPI ASL Checkpoints Status Code Description 0x01 System is entering S1 sleep state 0x02 System is entering S2 sleep state 0x03 System is entering S3 sleep state 0x04 System is entering S4 sleep state 0x05 System is entering S5 sleep state 0x10 System is waking up from ...

Страница 158: ...planation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the fan speed rpm 2 Temp Sensor SYS_Air_Outlet RT3 and MB_Air_Inlet RT2 They detect the system temperature around NOTE The system temperature is measured in a scale defined by Intel not in Fahrenheit or Ce...

Страница 159: ...http www tyan com 159 BIOS Temp Sensor Name Explanation ...

Страница 160: ...http www tyan com 160 ...

Страница 161: ...re of CPU1 DIMM channel C slot P1_UMC1_CH_D The highest temperature of CPU1 DIMM channel D slot P1_UMC0_CH_E The highest temperature of CPU1 DIMM channel E slot P1_UMC1_CH_F The highest temperature of CPU1 DIMM channel F slot P1_UMC0_CH_G The highest temperature of CPU1 DIMM channel G slot P1_UMC1_CH_H The highest temperature of CPU1 DIMM channel H slot PCH_Temp The highest temperature of PCH_Temp...

Страница 162: ...PCIE PORT 2A2B2C2D PStack2 corresponds to IOU2 PCIE PORT 3A3B3C3D 2U SKU PCIE slot populates riser card BIOS Setup IIO Configuration PCIE PORT PCIE Slot Location Riser Type Reference on UG Socket0 Configuration IOU2 IIO PCIe Br3 3A3B3C3D E PCIE M7120 L24 3F up Chapter 2 4 Board Parts Jumpers and Connectors and Motherboard Components Socket0 Configuration IOU2 IIO PCIe Br3 3C3D E PCIE M7120 L24 3F ...

Страница 163: ...Slot Location Riser Type Reference on UG Socket0 Configuration IOU2 IIO PCIe Br3 3A3B3C3D E PCIE M7120 L16 1F chapter 2 4 Board Parts Jumpers and Connectors and Motherboard Components Socket1 Configuration IOU1 IIO PCIe Br2 2A2B2C2D D PCIE M7120 R16 1F PCIe x16 FH HL cards In Left and Right 1U riser cards M7120 L16 1F Sold separately M7120 R16 1F Sold separately ...

Страница 164: ...http www tyan com 164 NOTE ...

Страница 165: ...B serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth results in greater speed BBS BIOS Boot Specification a feature within the BIOS that creates prioritizes and maintains a list of all Initial Program Load IPL devices and then stores that list in NVRAM IPL devic...

Страница 166: ...eight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after another Parallel ports transmit the bits of a byte on eight different wires at the same time that is in parallel form eight bits at the same time DDR Double Data Rate a technology designed to double the clock speed of the memory It activates output on bo...

Страница 167: ...tware that controls the system hardware Form factor an industry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form factors are the AT and ATX Global timer onboard hardware timer such as the Real Time Clock RTC HDD stands for Hard Disk Drive a type of fixed drive H SYNC controls the horizontal synchronization pro...

Страница 168: ...faster than the ISA bus Local buses are those which operate within a single system as opposed to a network bus which connects multiple systems PCI PIO PCI Programmable Input Output modes the data transfer modes used by IDE drives These modes use the CPU for data transfer in contrast DMA channels do not PCI refers to the type of bus used by these modes to communicate with the CPU PCI to PCI Bridge ...

Страница 169: ...e it can keep two sets of memory addresses open simultaneously By transferring data alternately from one set of addresses and then the other SDRAM cuts down on the delays associated with non synchronous RAM which must close one address bank before opening the next Serial port called as such because it transmits the eight bits of a byte of data along one wire and receives data on another single wir...

Страница 170: ...board or joystick port It is fast enough to support video transfer and is capable of supporting up to 127 daisy chained peripheral devices VGA Video Graphics Array the PC video display standard V SYNC controls the vertical scanning properties of the monitor ZCR Zero Channel RAID PCI card that allows a RAID card to use the onboard SCSI chip thus lowering cost of RAID solution ZIF Socket Zero Insert...

Страница 171: ...comprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find the latest software and operating system components to keep their systems running as powerful and productive as possible TYAN also ranks high for its commitment to fast and friendly customer support through email By offering plenty of options for...

Страница 172: ...ned by turning the equipment off and on the user is encouraged to try one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Plug the equipment into an outlet on a circuit different from that of the receiver Consult the dealer on an experienced radio television technician for help Notice for Canada This appara...

Отзывы: