5.3.7.1      COM1 / COM2 Console Redirection Settings   

 

 
 
Terminal Type   

Emulation: ANSI: Extended ASCII char set. VT100: ASCII char set.   
VT100+: Extends VT100 to support color, function keys, etc.   
VT-UTF8: Uses UTF8 encoding to map Unicode chars onto 1 or more bytes.

 

VT100 / 

VT100+

 / VT-UTF8 / ANSI   

 
Bits per Second 

Select serial port transmission speed. The speed must be matched on the other side. 
Long or noisy lines may require lower speeds. 

9600 / 19200 / 38400 / 57600 / 

115200

   

 
Data Bits 

8 / 

 
Parity 

A parity bit can be sent with the data bits to detect some transmission errors. Even: 
parity bit is 0 if the num of 1’s in the data bits is even. Odd: parity bit is 0 if the num of 
1’s in the data bits is odd. Mark: parity bit is always 1. Space: parity bit is always 0. 
Mark and Space parity do not allow for error detection. 

None / 

Even / Odd / Mark / Space 

 

Содержание B5556G24EV4HR-2T

Страница 1: ...1 http www tyan com GT24E B5556 Service Engineer s Manual ...

Страница 2: ...ding liability or warranties relating to fitness for a particular purpose or merchantability MITAC retains the right to make changes to produce descriptions and or specifications at any time without notice In no event will MITAC be held liable for any direct or indirect incidental or consequential damage loss of use loss of data or other malady resulting from errors or inaccuracies of information ...

Страница 3: ...se limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely ...

Страница 4: ...ery in fire There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer Dispose of used battery according to manufacturer instructions and in accordance with your local regulations VCCI A この装置は クラスA機器です この装置を住宅環境で使用すると電波妨害を引き 起こすことがあります この場合には使用者が適切な対策を講ずるよう要求される ことがあります VCCI A Safety IEC EN 62368 1 This equipment i...

Страница 5: ...apter 3 Replacing the Pre installed Components This chapter covers the removal and replacement procedures for pre installed components Chapter 4 Motherboard Information This chapter lists the hardware setup procedures that you need to abide by when installing system components It includes description of the jumpers and connectors on the motherboard Chapter5 BIOS Setup This chapter tells how to cha...

Страница 6: ...n to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it will not be in the way of foot traffic Follow all warnings and cautions in this manual and on the unit case Do not push objects in the ventilation slots as they may touch high voltage components and result in shock and damage to the components When replacing parts ensure that you use parts speci...

Страница 7: ...ed Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space Warning This symbol indicates the presence of hazardous energy circuits or electric shock hazards Refer all servicing to qualified personnel Warning This symbol indicates the presence of a hot surface or hot component If this surface is contacted the potential for in...

Страница 8: ...tem in or near a plenum air duct radiator or heat register Never use the product in a wet location Equipment Chassis Do not block or cover the openings to the system Never push objects of any kind through openings in the equipment Dangerous voltages might be present Conductive foreign objects can produce a short circuit and cause fire electric shock or damage to your equipment Lift equipment using...

Страница 9: ... a time A rack might become unstable if more than one component is extended To avoid damage to the equipment The rack width and depth must allow for proper serviceability and cable management Ensure that there is adequate airflow in the rack Improper installation or restricted airflow can damage the equipment The rack cannot have solid or restricted airflow doors You must use a mesh door on the fr...

Страница 10: ...from the electrical outlet grasp the cord by the plug To reduce the risk of electrical shock disconnect all power cords before servicing the appliance Equipment Batteries The system battery contains lithium manganese dioxide If the battery pack is not handled properly there is risk of fire and burns Do not disassemble crush puncture short external contacts or dispose of the battery in fire or wate...

Страница 11: ...s rings or loose jewelry when working before removing covers and touching internal components Do not use conductive tools that could bridge live parts Use gloves when you remove or replace system components they can become hot to the touch If the product sustains damage requiring service disconnect the product from the AC electrical outlet and refer servicing to an authorized service provider Exam...

Страница 12: ...12 http www tyan com ...

Страница 13: ... 2 Replacing the Chassis Cover 39 2 1 3 Installing the CPU Heatsink and Air Duct 40 2 1 4 Installing the Memory 44 2 1 5 Installing the PCI E Card 46 2 1 6 Installing the GPU Card 48 2 1 7 Installing Hard Drives 51 2 2 Rack Mounting 58 2 2 1 Installing the Server in a Rack 58 Chapter 3 Replacing Pre Installed Components 63 3 1 Introduction 63 3 2 Disassembly Flowchart 63 3 3 Removing the Cover 64 ...

Страница 14: ... Help 104 5 1 3 In Case of Problems 104 5 1 4 Setup Variations 104 5 2 Main Menu 105 5 3 Advanced Menu 107 5 3 1 iSCSI Configuration 109 5 3 2 Option ROM Dispatch Policy 116 5 3 3 Trusted Computing 117 5 3 4 CPU Configuration 120 5 3 5 Server ME Configuration 124 5 3 6 ACPI Settings 125 5 3 7 Serial Port Console Redirection 126 5 3 8 PCI Subsystem Settings 132 5 3 9 Network Stack Configuration 133...

Страница 15: ...s 175 5 7 2 Hard Drive BBS Priorities 176 5 7 3 Add New Boot Option 177 5 7 4 Delete Boot Option 178 5 8 Save Exit 179 Chapter 6 Diagnostics 181 6 1 Flash Utility 181 6 2 AMIBIOS Post Code Aptio 182 Appendix I Cable Connection Tables 189 Appendix II Fan and Temp Sensors 193 Appendix III FRU Parts Table 197 Appendix IV Technical Support 199 ...

Страница 16: ...16 http www tyan com ...

Страница 17: ...E bus implementation The GT24E B5556 not only empowers your company in nowadays IT demand but also offers a smooth path for future application usage TYAN also offers the GT24E B5556 in a version that can support up to four hot swap 2 5 3 5 and two internal 2 5 SATA SSDs The GT24E B5556 uses TYAN s latest chassis featuring a robust structure and a solid mechanical enclosure All of this provides GT2...

Страница 18: ... 3 LAN 1 BMC event I O Ports 2 USB 3 1 Gen1 ports External Drive Bay Q ty Type 4 3 5 2 5 Hot Swap SSD HDD HDD Backplane Support SAS 12Gb s SATA 6Gb s Supported HDD Interface 4 SATA 6Gb s Internal Drive Bay Type Q ty 2 2 5 fixed SSD with height up to 9 5mm Supported HDD Interface 2 SATA 6Gb s System Cooling Configuration FAN 4 4028 fans Air Duct 1 Air duct of CPU Power Supply Type RPSU Input Range ...

Страница 19: ... POR Memory channel 2 Channels per CPU Memory voltage 1 2V Expansion Slots PCI E 1 PCI E Gen3 x8 slot 1 PCI E Gen3 x16 slot HH HL or 2 PCI E Gen3 x8 slots HH HL split by Mux Pre install TYAN Riser Card 1 M7081 R8 1L riser card for 1 PCI E Gen3 x8 slot 1 M5556 L16 2F riser card for 1 FH FL PCI E Gen3 x16 slot or 2 FH FL PCI E Gen3 x8 slots LAN Q ty Port 2 10GbE ports 1 GbE port dedicated for IPMI C...

Страница 20: ...set power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature 24 bit high quality video compression Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2500 IPMI Feature IPMI 2 0 compliant baseboard management controller BMC 10 100 1000 Mb s MAC int...

Страница 21: ... 2T N System Form Factor 1U Rackmount Chassis Model GT24E Dimension D x W x H 25 4 x 17 2 x 1 72 645 x 436 x 43 6mm Motherboard Name S5556GM2NR 2T Gross Weight 21 kg 46 5 lbs Net weight 15 5 kg 34 5 lbs Front Panel Buttons 1 RST 1 NMI 1 ID 1 PWR w LED LEDs 1 HDD 1 ID 3 LAN 1 BMC event I O Ports 2 USB 3 1 Gen1 ports External Drive Bay Q ty Type 4 3 5 2 5 Hot Swap SSD HDD HDD Backplane Support SAS 1...

Страница 22: ... Xeon E 2200 2100 series processors 9th 8th Gen Intel Core i3 processors Thermal Design Power TDP Wattage Max up to 95W Chipset PCH Intel C242 Memory Supported DIMM Qty 4 DIMM slots DIMM Type Speed UDIMM ECC DDR4 2666 2400 Capacity Up to 128GB Follow latest Intel DDR4 Memory POR Memory channel 2 Channels per CPU Memory voltage 1 2V Expansion Slots PCI E 1 PCI E Gen3 x8 slot 1 PCI E Gen3 x16 slot H...

Страница 23: ...TPM supported list System Monitoring Chipset Aspeed AST2500 Temperature Monitors temperature for CPU memory system environment Voltage Monitors voltage for CPU memory chipset power supply LED Over temperature warning indicator Fan PSU fail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature 24 bit high quality video compression ...

Страница 24: ... A CE DoC Class A CB LVD Yes RCM Class A VCCI Class A Operating Environment Operating Temp 10 C 35 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Package Contains Barebone 1 GT24E B5556 Barebone Manual 1 Quick Installation Guide NOTE 1 The specifications are subject to change without prior notice 2 Please visit ou...

Страница 25: ...ard pre installed M1620G24E D PDB Power Distribution Board pre installed M1283G24 BP12E 4 HDD Backplane Board pre installed M1713G24 FPB Front Panel Board pre installed M7081 R8 1L 1U Riser Card pre installed M5556 L16 2F 1U Riser Card pre installed 4 40x28mm system fans pre installed in B5556G24EV4HR 2T SKU 3 40x28mm 2 40x56mm system fans pre installed in B5556G24EV4HR 2T N SKU GT24E B5556 Access...

Страница 26: ...uct 1 5 1 System Front View M1713G24 FPB Front Panel Board M1713G24 FPB Front Panel Board 1 Power Button with green LED 7 ID LED 2 LAN3 LED no function 8 Reset Button 3 LAN2 LED 9 NMI Button 4 LAN1 LED 10 ID Button 5 Warning LED 11 USB3 1 Gen1 Port 2 6 HDD LED 12 USB3 1 Gen1 Port 1 ...

Страница 27: ...een solid on Access Blinking Warning LED Amber System Normal Off System Warning Amber solid on LAN1 LED Green Access Blinking Link Solid on LAN2 LED Green Access Blinking Link Solid on LAN3 LED Green No Function HDD LED LED State Color Description Activity LED Solid On Green Drive present no activity Blinking Drive present with activity Status LED Solid On Red HDD Failed Blinking 1Hz Identify Blin...

Страница 28: ...LAN3 dedicated IPMI support for BMC 4 USB3 1 Gen2 Ports 5 VGA Port 6 Serial Port 7 LAN2 8 LAN1 9 Low profile expansion card area PCIE 03 10 ID LED blue 11 Full height full length expansion card area PCIE 01 12 Full height full length expansion card area PCIE 02 ...

Страница 29: ...itions Bicolor Power Supply Condition GREED LED AMBER LED No AC power to all power supplies OFF OFF Power supply critical event causing a shutdown failure OCP OVP Fan Fail OTP UVP OFF Amber Solid ON Power supply warning events where the power supply continues to operate high temp high power high current 107 slow fan OFF o 5Hz Blink Amber AC present only 12VSB on PS off PS in Smart Redundant state ...

Страница 30: ...d On Active Green Blinking Yellow Solid On 10 Gbps Link Yellow Solid On Yellow Solid On Active Yellow Blinking Yellow Solid On 1Gbps LAN Port LAN Indication 1Gbps LAN Link Activity LED Scheme Left LED Link Activity LED Color Green Right LED Speed LED Color Amber No Link OFF OFF 10 Mbps Link Green Solid On OFF Active Green Blinking OFF 100 Mbps Link Green Solid On Green Solid On Active Green Blinki...

Страница 31: ...31 http www tyan com 1 5 3 System Top View B5556G24EV4HR 2T N Internal SSD Sequence ...

Страница 32: ...4HR 2T 1 Hot swap HDD trays 5 PSU1 2 M1283G24 BP12E 4 HDD Backplane Board 6 PSU0 3 System fans 7 Riser Card Bracket M7081 R8 1L pre installed 4 M1620G24E D PDB Power Distribution Board 8 Riser Card Bracket M5556 L16 2F pre installed ...

Страница 33: ...33 http www tyan com 1 5 4 Chassis Dimensions ...

Страница 34: ...34 http www tyan com NOTE ...

Страница 35: ...n prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap or an anti static pad A T30 Security Torx screwdriver Most of the electrical and mechanical connections can be disconnected with your hands It is recommended that you do not use pliers to remove co...

Страница 36: ... any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always place it on a grounded anti static surface until you are ready to reinstall it Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do so Do...

Страница 37: ... how to install components on to the mainboard including CPUs memory modules and add on cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove GT24E B5556 chassis cover 1 Loosen the thumb screw and the screw on the right side 2 Slide to lift the rear top cover up ...

Страница 38: ...38 http www tyan com ...

Страница 39: ...instructions to replace the GT24E B5556 top chassis cover 1 Place the top cover onto the chassis and slide the top cover into place 2 Tighten the thumbscrew NOTE The thumbscrew should be tightened with a screwdriver after the top chassis are closed 3 Screw the top cover ...

Страница 40: ...ww tyan com 2 1 3 Installing the CPU Heatsink and Air Duct Follow the steps below to install the processor heatsink and air duct 1 Take out the protection cap 2 Open the socket lever to lift up the socket cover ...

Страница 41: ...41 http www tyan com ...

Страница 42: ...42 http www tyan com 3 Install the processor and make sure the gold arrow is located in the right direction 4 Close the socket cover 5 Close the socket lever ...

Страница 43: ...ct Secure the heatsink screws NOTE The thermal grease has been applied to the bottom of the heatsink 7 Align and install the alignment tab on the air duct underneath the fan bracket on the chassis Make sure the air flow direction is correct Secure the air duct to the chassis with two screws ...

Страница 44: ...memory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly the memory slot locking levers lock automatically onto the indentations at the ends of the module Follow the recommended memory population table to install the other memory modules ...

Страница 45: ...0_MC0_DIM_CH_A1 P0_MC0_DIM_CH_B0 P0_MC0_DIM_CH_B1 01 02 03 04 05 06 07 08 NOTE 1 Supported DDR4 ECC and Non ECC UDIMM 2 The memory slots of DDR4 channels should be populated on a farthest first fashion This means that blue connector cannot be populated if black is empty 3 indicates a populated DIMM slot ...

Страница 46: ... tyan com 2 1 5 Installing the PCI E Card Follow these instructions to install the PCI E card 1 Unscrew the riser card bracket 2 Remove the riser card bracket from the chassis 3 Unscrew to remove the dummy bracket ...

Страница 47: ...47 http www tyan com 4 Insert the PCI E card into the riser card bracket and screw it firmly 5 Reposition and screw the riser card bracket into the chassis ...

Страница 48: ...48 http www tyan com 2 1 6 Installing the GPU Card Follow these instructions to install the GPU card 1 Loosen 6 screws to lift up the GPU riser card bracket 2 Unscrew to remove both dummy brackets ...

Страница 49: ...he GPU card into the GPU riser card bracket and screw it firmly 4 Making sure the alignment tabs are properly aligned install the GPU air duct on the GPU riser card bracket and secure the GPU air duct to the GPU card with two screws ...

Страница 50: ...yan com 5 Turn the GPU riser card bracket over and use four screws to secure the GPU card to the riser bracket 6 Connect the GPU cable 7 Reinsert the GPU riser card bracket into the chassis and secure with 6 screws ...

Страница 51: ...SD and two 2 5 internal SSD Installing 3 5 Hot Swap Hard Drives Follow these instructions to install a 3 5 HDD Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch and pull the locking lever open 2 Slide the HDD tray out ...

Страница 52: ...yan com 52 3 Place the 3 5 hard disk drive into the HDD tray and secure the HDD to the HDD tray using 4 screws 4 Reinsert the HDD tray into the chassis Push to secure the locking lever until it clicks into place ...

Страница 53: ...a 2 5 HDD SSD Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Press the locking lever latch and pull the locking lever open 2 Slide the HDD tray out 3 Place the 2 5 HDD SSD into the HDD tray and align the 2 5 HDD SSD with its guide pins ...

Страница 54: ...54 http www tyan com 4 Turn over the HDD tray and secure the HDD SSD to the tray using 4 screws 5 Reinsert the HDD tray into the chassis Push to secure the locking lever until it clicks into place ...

Страница 55: ...alling 2 5 Internal Hard Drives Follow these instructions to install a 2 5 SSD Warning Always install the hard disk drive to the chassis after the chassis has been secured on the rack 1 Unscrew the front top cover to lift it up ...

Страница 56: ...56 http www tyan com 2 Remove the paper tapes 3 Connect the SATA and power cables 4 Align the 2 5 SSD with guide pins and slightly pull to place it in ...

Страница 57: ...57 http www tyan com ...

Страница 58: ...ack x 1 2 2 1 Installing the Server in a Rack Follow these instructions to mount the TYAN GT24E B5556 into an industry standard 19 rack NOTE Before mounting the TYAN GT24E B5556 in a rack ensure that all internal components have been installed and that the unit has been fully tested However to make the installation easier we suggest that you remove all HDD trays before you insert the chassis into ...

Страница 59: ...s shown using four screws from the supplied mounting ears screw pack 2 Draw out the inner rail from the rail assembly When the rail comes to a stop pull the tab to release the latch and completely draw the inner rail out 3 Align the inner sliding rail on the side of the server and pull towards the arrow to secure the hooks ...

Страница 60: ...60 http www tyan com 4 Secure the inner sliding rail to the server using one M4 x 4L screw B 5 Repeat steps 2 to 4 to secure the sliding rail to the other side of the server ...

Страница 61: ...to the Unit Secure the outer rails to the rack using four M5 screws and four washers A on each side Rack Mounting the Server 1 Draw out the middle rail to the latch position 2 Lift the unit and then insert the inner slide rails into the middle rails ...

Страница 62: ...62 http www tyan com 3 When the inner rails come to a stop pull the tab to release the latch and push the whole system in 4 Secure the mounting ears of the unit to the rack using two M5 x 20L screws C ...

Страница 63: ...the pre installed components including the Motherboard M1713 G24 FPB Front Panel Board M1283G24 BP12E 4 HDD Backplane M1620G24E D PDB Power Distribution board M7081 R8 1L and M5556 L16 2F Riser cards System fan and Power supply unit etc 3 2 Disassembly Flowchart The following flowchart outlines the disassembly procedure ...

Страница 64: ...d Components Follow these instructions to replace motherboard components including the motherboard 3 4 1 Replacing the M7081 R8 1L Riser Card Follow these instructions to replace the M7081 R8 1L Riser card 1 Unscrew to lift up the riser card bracket 2 Unscrew the M7081 R8 1L riser card to replace with a new one 3 Follow the steps described earlier in reverse to reinstall the riser card bracket ...

Страница 65: ...http www tyan com 65 3 4 1 1 M7081 R8 1L Riser Card Features Form Factor Dimension 30mmx106 27mm Specifications 1 PCI E x8 Gen3 ...

Страница 66: ...d Follow these instructions to replace the M5556 L16 2F Riser card 1 Loosen 6 screws to lift up the GPU card bracket 2 Unscrew the M5556 L16 2F riser card to replace with a new one 3 Follow the steps described earlier in reverse to reinstall the riser card bracket ...

Страница 67: ... Features Form Factor Dimension 31 64mm x 255mm Specifications 1 PCI E x16 Gen3 Slot J4 1 PCI E x8 Gen3 Slot J5 1 PCIE PCIE Config Jumper J25 NOTE 1 PCIE PCI E configured DESIGN NOTE SLOT STATUS Pin 1 2 closed J4 x16 J5 Disable Pin 2 3 closed J4 x8 J5 x8 ...

Страница 68: ...68 http www tyan com 3 4 3 Replacing the Front Panel Board Follow these instructions to replace the M1713G24 FPB Front Panel Board 1 Unscrew to lift up the front top cover ...

Страница 69: ...3 Remove the rubber stubs securing the mylar to the Front Panel Board 4 Lift the front panel board free from the mylar Replace the Front Panel Board as shown below 5 After replacing the front panel board insert the Front Panel Board into the chassis following the above procedures in reverse ...

Страница 70: ...Panel Board in details Form Factor 97x45 2 mm 4 layer PCB Specifications 1 10x2 pin USB3 0 Header connected to MB 1 15x2 pin Header connected to MB 2 USB3 1 Gen1 Connector LEDs 1 Green Blue LED for LAN1 and ID 1 Green Green LED for LAN2 and HDD 1 Green Amber LED for LAN3 and BMC 1 Power LED ...

Страница 71: ...X_P0 6 16 GND GND 7 17 FP_USB3_RX_P1 USB0 8 18 FP_USB3_RX_N1 USB0 9 19 VCC_USB NC 10 20 Key J3 Front Panel Board Connector Definition Pin Pin Definition PW_LED 1 16 ICH_SMBDAT VCC 2 17 GND Key 3 18 ICH_SMBCLK ID_LED 4 19 ID_SW PW_LED 5 20 INTRU ID_LED 6 21 TEMP_SENSOR HDD_LED 7 22 LAN2_LED SYS_FAULT1 8 23 NMI_SW HDD_LED 9 24 LAN2_LED SYS_FAULT2 10 25 NC PWR_SW 11 26 NC LAN1_LED 12 27 LAN3_LED GND ...

Страница 72: ...72 http www tyan com 3 4 4 Replacing the System Fan Follow these instructions to replace the fan 1 Disconnect the fan cable 2 Take out the fan from the chassis 3 Release the rubber screws from the fan ...

Страница 73: ...73 http www tyan com 4 Release the rubber screws and the push pins from the fan 5 Replace the failed fan module with a new one Follow the procedures described earlier in reverse order to reinstall ...

Страница 74: ...detach the HDD backplane please remove all the HDD trays with HDDs otherwise the HDD backplane will be damage when strains at the disassembly 1 Remove all fans Disconnect all cables connected to the M1283G24 BP12E 4 HDD Backplane 1 Unscrew to lift up the HDD BP Board Bracket ...

Страница 75: ... The HDD BP Board bracket is as shown below 3 Unscrew to remove the BP mylar and replace with a new HDD backplane board 4 Follow the procedures described earlier to reinstall the HDD backplane board bracket into the chassis ...

Страница 76: ...1 HDD Backplane Board Features Front View Rear View Form Factor Dimension 422 4 29 8mm Specifications Overview 1 OCuLink x8 Connector Input 1 Mini SAS Connector Input 4 SATA HDD SSD or 2 SATA HDD SSD 2 NVMe Output 6 FAN connector ...

Страница 77: ...D2 HDD3 SATA0_3 NVMe01 PW1 PW2 FAN1 FAN2 FAN3 FAN4 FAN5 FAN6 SATA NVMe Connector SATA NVMe Connector SATA Connector SATA Connector Mini SAS Connector OCU Link Connector Power Connector Power Connector FAN Connector FAN Connector FAN Connector FAN Connector FAN Connector FAN Connector ...

Страница 78: ...s to replace the M1260G24E D PDB Power Distribution Board in your system 1 Disconnect all cables connected to the power distribution board 2 Unscrew to take off the power distribution board and replace with a new one 3 Insert the PDB into the chassis following the above procedures in reverse ...

Страница 79: ...oard Features 3 4 6 2 Connector Definitions Location Definition J2 J3 PWR1 PW2 PW5 PW3 PW4 PW1 DOM_5V_PW1 DOM_5V_PW2 Power Supply slot Power Supply slot ATX Power 12x2 ATX Power 4x2 ATX Power 4x2 HDD Power 4x1 HDD Power 4x1 PM Bus DOM Power DOM Power ...

Страница 80: ...ower Supply Follow these instructions to replace the power supply module in your system 1 Press the latch to pull the power supply out 2 After replacing a new power supply press and hold the latch to push the power supply back into the chassis ...

Страница 81: ...81 http www tyan com 3 4 8 Disconnecting All Motherboard Cables 1 Disconnect all cables connected to the motherboard ...

Страница 82: ...l of the aforementioned cables follow the instructions below to remove the motherboard from the chassis 1 Remove the air duct processor and heatsink if installed 2 Remove six screws securing the motherboard to the chassis 3 Carefully lift the motherboard from the chassis ...

Страница 83: ...est conditions MITAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the motherboard components IC chips connectors memory modules and leads 4 Place the motherboard on a grounded antistatic surface or on the antistatic bag that the board was shipped in 5 Inspect the board for d...

Страница 84: ...4 http www tyan com 4 1 Board Image S5556 This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above picture ...

Страница 85: ...85 http www tyan com 4 2 Block Diagram S5556 ...

Страница 86: ...86 http www tyan com 4 3 Motherboard Mechanical Drawing ...

Страница 87: ...sion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM population guidelines shown later in the manual For the latest board revision please visit our web site at http www tyan com ...

Страница 88: ..._ATX_PWR PW1 6 PCI Express Slot X16 OPEN END J55 18 SATA SATA DOM J16 7 10Px2_FAN Board Header J39 19 12Px2 SSI_FP Header J32 8 4p FAN Connector J37 20 SATA SATA DOM J19 9 4p FAN Connector J35 21 2Port_USB3 1 GEN1 Header J74 10 4p FAN Connector J40 22 5Px2 SGPIO Header J24 11 4p FAN Connector J38 23 4P_IPMB Header J31 12 4p FAN Connector J34 Jumpers a ME FIRMWARE UPDATE J10 d PSU Alert Function J1...

Страница 89: ... BMC_SW_HEARTBRAT LED2 viii RED CATERR LED1 LED11 iii GRN BMC_HW_HEARTBRAT LED6 ix GRN SYSTEM1 RST LED iv RED DIMM Error LED3 x RED PSMI_ALERT_LED v RED DIMM Error LED4 xi ID LED SW1 vi RED DIMM Error LED7 Jumper Legend OPEN Jumper OFF Without jumper cover CLOSED Jumper ON With jumper cover ...

Страница 90: ...CH4 7 8 TACH9 TACH5 9 10 TACH10 GND 11 12 KEY PWM2 13 14 PWM1 TACH11 15 16 SDA TACH12 17 18 SCL P3V3_AUX 19 20 PWM3 J32 Front Panel Header Signal Pin Pin Signal PW_LED 1 2 FP_PWR KEY 3 4 ID_LED PWR_LED 5 6 ID_LED HDD_LED 7 8 FAULT_LED1 HDD_LED 9 10 FAULT_LED2 PWR_SW 11 12 LAN1 ACTLED GND 13 14 LAN1 ACTLED RST_SW 15 16 SMBus SDA GND 17 18 SMBus SCL SYS_ID_SW 19 20 INTRUSION TEMP SENSOR 21 22 LAN2 A...

Страница 91: ...s to the Serial ATA ready drives via the Serial ATA cable J16 SATA0 SATADOM1 J19 SATA1 SATADOM2 1 GND 2 Tx_DP 3 Tx_DN 4 GND 5 Rx_DN 6 Rx_DP 7 GND P1 VCC P5V P2 GND J74 USB3 1 Gen1 Header Signal Pin Pin Signal VCC P5V 1 20 KEY USB3 1_P1_RX_DN 2 19 VCC P5V USB3 1_P1_RX_DP 3 18 USB3 1_P2_RX_DN GND 4 17 USB3 1_P2_RX_DP USB31_P1_TX_DN 5 16 GND USB31_P1_TX_DP 6 15 USB31_P2_TX_DN GND 7 14 USB31_P2_TX_DP ...

Страница 92: ...eed to clear the system BIOS setting 1 Power off system and disconnect power connectors from the motherboard 2 Remove the jumper from Pin_1 and Pin_2 Default setting 3 Move the jumper cap to close Pin_2 and Pin_3 for several seconds to Clear CMOS 4 Put jumper cap back to Pin_1 and Pin_2 Default setting 5 Reconnect power connectors to the motherboard and power on system Clear CMOS J10 ME Firmware U...

Страница 93: ...t Pin2 3 closed PCIE Bus is set to x8 PW1 ATX 24 pin Main Power Connector Signal Pin Pin Signal 3 3 Vdc 1 13 3 3 Vdc 3 3 Vdc 2 14 12 Vdc GND 3 15 GND 5 Vdc 4 16 PS_ON GND 5 17 GND 5 Vdc 6 18 GND GND 7 19 GND PWR_OK 8 20 NC 5 VSB 9 21 5 Vdc 12 Vdc 10 22 5 Vdc 12 Vdc 11 23 5 Vdc 3 3 Vdc 12 24 GND PW2 CPU and Memory Power Connector Signal Pin Pin Signal GND 1 5 12 Vdc GND 2 6 12 Vdc GND 3 7 12 Vdc GN...

Страница 94: ... cannot be detected or properly initiated Blinking Green The LED blinks per second to indicate that the BMC software is working normally LED6 BMC_HW_HEARTBRAT GRN Pin Signal 3V_AUX GND State Description OFF OFF The LED shuts off when the BMC controller cannot be detected or properly initiated Blinking Green The LED blinks per second to indicate that the BMC controller is working normally ...

Страница 95: ...detected or properly initiated LED7 DIMM Error RED Pin Signal 3V_AUX GND State Description OFF OFF The LED shuts off when the DIMM is healthy and working Blinking RED The LED blinks per second to indicate that the DIMM cannot be detected or properly initiated LED8 DIMM Error RED Pin Signal 3V_AUX GND State Description OFF OFF The LED shuts off when the DIMM is healthy and working Blinking RED The ...

Страница 96: ...ED shuts off when the system of CPU is abnormal ON Green The LED lights up when the power of CPU is normally LED12 SYSTEM2 RST LED Pin Signal GND 3V State Description OFF OFF The LED shuts off when the power of system is abnormal ON Green The LED lights up when the power of system is normally ...

Страница 97: ...o touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred to as thermal compound Simply apply a thin layer on to the CPU lid applying too much will actually reduce the cooling NOTE Always check with the manufacturer of the heat sink processor to ensure that the therm...

Страница 98: ...t simply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard will not be able to be securely installed NOTE Be especially careful to look for extra stand offs If there are any stand offs present that are not aligned with a mounting hole on the motherboard it wi...

Страница 99: ...ead of metal Although the plastic studs are usable MITAC recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common motherboard studs look like and how they should be installed ...

Страница 100: ... type of memory recommended for your motherboard This platform supports 4 DDR4 slots Up to 128GB UDIMM ECC DDR4 2666 2400 are supported 1 2V DDR4 DIMMs are supported All installed memory will automatically be detected No jumpers or settings need to be changed for memory detection All memory must be of the same type and density Different memory types can NOT be mixed and matched on the same motherb...

Страница 101: ...DIM_CH_A1 P0_MC0_DIM_CH_B0 P0_MC0_DIM_CH_B1 01 02 03 04 05 06 07 08 NOTE 1 Supported DDR4 ECC and Non ECC UDIMM 2 The memory slots of DDR4 channels should be populated on a farthest first fashion This means that blue connector cannot be populated if black is empty 3 indicates a populated DIMM slot ...

Страница 102: ...properly especially SATA cables and most importantly jumpers You may have difficulty powering on your system if the motherboard jumpers are not set correctly In the rare circumstance that you have experienced difficulty you can find help by asking your vendor for assistance If they are not available for assistance please find setup information and documentation online at our website or by calling ...

Страница 103: ...s and configurations of the BIOS are current at the time of print and are subject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are then stored in a dedicated battery backed memory called NVRAM that retains the information even when the power is turn...

Страница 104: ...for best performance and reliability Even a seemingly small change to the Chipset setup options may cause the system to become unstable or unusable 5 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic look and function of the BIOS setup remains more or less the same for most systems the appearance of your Setup screen may differ from the charts shown in...

Страница 105: ...that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Memory Information This displays the total memory size System Date Set the Date Use Tab to switch between Date elements Default Ranges Year 2010 2079 Months 1 12 Days dependent on month System Time Set the Time Use Tab to switch between Time elements ...

Страница 106: ...http www tyan com 106 Access Level Read only ...

Страница 107: ...s for your system iSCSI Configuration Configure the iSCSI parameters Option ROM Dispatch Policy Option ROM Dispatch Policy Trusted Computing Trusted Computing Settings CPU Configuration CPU Configuration Parameters Server ME Configuration Server ME Configuration ACPI Settings System ACPI Parameters ...

Страница 108: ...ttings CSM Configuration CSM configuration Enable Disable Option ROM execution settings etc USB Configuration USB Configuration Parameters Onboard Device Configuration Onboard Device Configuration S5 RTC Wake Settings Enable system to wake from S5 using RTC alarm Super IO Configuration System Super IO Chip Parameters Hardware Health Configuration Hardware health Configuration Parameters ...

Страница 109: ...to iSCSI Server Step 1 Option ROM Dispatch Policy Settings Advanced Option ROM Dispatch Policy Onboard Lan1 I210 Enabled Advanced Option ROM Dispatch Policy Onboard Lan1 Option ROM type iSCSI Step 2 Network Stack Configuration Settings Set Advanced Network Stack Configuration Network Stack Enabled Step 3 CSM Configuration Settings ...

Страница 110: ...work UEFI Step 4 Save changes and reboot Step 5 Enter to SCSI Configuration Step 6 Set iSCSI Initiator Name Ex iqn xxx Step 7 Enter to Add an Attempt Step 8 Enter to a Device Ex MAC A0 42 3F 3A E4 B4 Step 9 Set Configuration items iSCSI Initiator Name The worldwide unique name of iSCSI Initiator Only IQN format is accepted Enter iqn xxx xxx ranges from 4 to 223 ...

Страница 111: ...http www tyan com 111 3 3 1 1 Add an Attempt Read only This MAC address is for iSCSI and subject to change NOTE Only LAN1 supports iSCSI function ...

Страница 112: ...itiator IP address is system assigned in IP6 mode In Autoconfigure mode iSCSI driver will attempt to connect iSCSI target via IPv4 stack if failed then attempt IPv6 stack IP4 IP6 Autoconfigure Connection Retry Count The minimum value is 0 and the maximum is 16 0 means no retry Connection Establishing Timeout The timeout value in milliseconds The minimum value is 100 milliseconds and the maximum is...

Страница 113: ... Mask Enter IP address in dotted decimal notation Gateway Enter IP address in dotted decimal notation Target Name The worldwide unique name of the target Only iqn format is accepted iqu xxx Target IP Address Enter IP address in dotted decimal notation Target Port Target Port Boot LUN Hexadecimal representation of the LU number Examples are 4752 3A4F 6b7e 3F99 6734 9 156f 127 4186 9 Authentication ...

Страница 114: ...http www tyan com 114 5 3 1 2 Delete Attempts Commit Changes and Exit Commit Changes and Exit Discard Changes and Exit Discard Changes and Exit ...

Страница 115: ...http www tyan com 115 5 3 1 3 Change Attempt Order Commit Changes and Exit Commit Changes and Exit Discard Changes and Exit Discard Changes and Exit ...

Страница 116: ...board LAN1 X550 Enable or disable onboard LAN1 Option ROM Disabled Enabled Onboard LAN2 X550 Enable or disable onboard LAN2 Option ROM Disabled Enabled PCIE 1 Not Found PCIE 3 Not Found Enable or Disable Option ROM execution for selected Slot Disabled Enabled ...

Страница 117: ...om 117 5 3 3 Trusted Computing Security Device Support Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available Enabled Disabled ...

Страница 118: ...s or Disables SHA256 PCR Bank Enabled Disabled Pending operation Schedule an operation for the Security Device NOTE Your Computer will reboot during restart in order to change State of Security Device None TPM Clear Platform Hierarchy Enable or Disable Platform Hierarchy Disabled Enabled Storage Hierarchy Enable or Disable Storage Hierarchy Disabled Enabled ...

Страница 119: ...cal Presence Spec Version Select to Tell O S to support PPI Spec Version 1 2 or 1 3 Note some GCJ tests might not support 1 3 1 2 1 3 TPM 2 0 Interface Type Read only PM Randomization Enable or Disable Platform Hierarchy randomization Disabled Enabled Device Select TPM 1 2 will restrict support to TPM 1 2 devices TPM 2 0 will restrict support to TPM 2 0 devices Auto will support both with the defa...

Страница 120: ...y and Disabled for other OS OS not optimized for Hyper Threading Technology Enabled Disabled NOTE If Hyper threading Technology is NO Support this item will be hidden Active Processor Cores Number of cores to enable in each processor package All 1 2 3 4 5 Intel VMX Virtualization Technology When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Enable...

Страница 121: ... Software Guard Extensions SGX Enable Disable Software Guard Extensions SGX Disabled Enabled Software Controlled Select Owner EPOCH input type There are three Owner EPOCH modes Each EPOCH is 64bit no change in owner epoch change to new random owner epoch and manually entered by user After generating new epoch via Change to New Random Owner EPOCHs the selection reverts back to No Change in Owner Ep...

Страница 122: ... Intel R SpeedStep tm Allows more than two frequency ranges to be supported Disabled Enabled Turbo Mode Enable Disable processor Turbo Mode requires Intel Speed Step or Intel Speed shift to be available and enabled Disabled Enabled Intel R Speed Shift Technology Enable Disable Intel R Speed Shift Technology support Enabling will expose the OPPC v2 interface to allow for hardware controlled P state...

Страница 123: ...n all cores enter C State Disabled Enabled Enhanced C states Enable Disable C1E When enabled CPU will switch to minimum speed when all cores enter C state Disabled Enabled Package C State Limit Maximum Package C State Limit Setting Cpu Default Leaves to Factory default value Auto Initializes to deepest available Package C State Limit C0 C1 C2 C3 C6 C7 C8 Cpu Default Auto ...

Страница 124: ...http www tyan com 124 5 3 5 Server ME Configuration Server ME Configuration Read only ...

Страница 125: ...http www tyan com 125 5 3 6 ACPI Settings Enable ACPI Auto Configuration Enables or Disables BIOS ACPI Auto Configuration Enabled Disabled ...

Страница 126: ...rvices EMS Console Redirection Console redirection enable or disable Disabled Enabled Legacy Console Redirection Settings Legacy Console redirection settings Console Redirection Settings The settings specify how the host computer which the user is using will exchange data Both computers should have the same or compatible settings ...

Страница 127: ...t serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 9600 19200 38400 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with the data bits to detect some transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even Odd parity bit is 0 if the num of 1 s in the data bits is odd Mark parity bit is alw...

Страница 128: ...ent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Enabled Disabled Recorder Mode On this mode enabled only text will be sent This is to capture Terminal data Disabled Enabled ...

Страница 129: ... Resolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST When Bootloader is selected the Legacy Console Redirection is disabled before booting to legacy OS When Always Enable is selected then Legacy Console Redirection is enabled for legacy OS Default setting for this option is set to Always Enable Always Enable BootLoader ...

Страница 130: ...erver OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Settings page for more Help with Terminal Type Emulation VT UTF8 VT100 VT100 ANSI Bits per Second Select serial port transmission speed The speed must be matched on the other side Long or noisy lines m...

Страница 131: ...ng data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS Software Xon Xoff Data Bits Parity Stop Bits Read only ...

Страница 132: ...ve 4G Decoding Enables or Disables 64bit capable Devices to be Decoded in Above 4G Address Space Enabled Disabled SR IOV Support If system has SR IOV capable PCIe Device this option Enables or Disables Single Root ID Virtualization Support Enabled Disabled ...

Страница 133: ...When Network Stack is set to Enabled Ipv4 PXE Support Enable Ipv4 PXE Boot Support If disabled IPV4 PXE boot option will not be created Disabled Enabled Ipv4 HTTP Support Enable Ipv4 HTTP Boot Support If disabled IPV4 HTTP boot option will not be created Disabled Enabled Ipv6 PXE Support Enable Ipv6 PXE Boot Support If disabled IPV6 PXE boot option will not be created Disabled Enabled ...

Страница 134: ...Enable Ipv6 HTTP Boot Support If disabled IPV6 HTTP boot option will not be created Disabled Enabled PXE boot wait time Wait time to press ESC key to abort the PXE boot 0 Media detect count Number of times presence of media will be checked 1 ...

Страница 135: ...bled Option ROM Messages Set display mode for Option ROM Force BIOS Keep Current Network Controls the execution of UEFI and Legacy PXE OpROM Legacy UEFI Storage Controls the execution of UEFI and Legacy Storage OpROM Legacy UEFI Video Controls the execution of UEFI and Legacy Video OpROM Legacy UEFI ...

Страница 136: ...http www tyan com 136 Other PCI Devices Determines OpROM execution policy for devices other than Network Storage or Video Legacy UEFI ...

Страница 137: ...EFI applications Enabled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled USB Mass Storage Driver Support Enable Disable USB Mass Storage Driver Support Enabled Disabled Port 60 64 Emulation Enables I O Port 60h 64h emulation support This should be enabled for the complete USB keyboar...

Страница 138: ...evice reset time out USB mass storage device Start Unit command time out 10 sec 20 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller AUTO uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Auto Manual ...

Страница 139: ... controller Onboard VGA Enable or disable onboard VGA Disabled Enabled LAN1 LAN2 LAN Enable Disable control function Disabled Enabled Chassis Intrusion Detection Enabled when a chassis open event is detected the BIOS will record the event Disabled Enabled NMI Button Enable or Disable NMI button Disabled Enabled ...

Страница 140: ... Time system will wake on the hr min sec specified Select Dynamic Time system will wake on the current time Increase minute s Disabled Fixed Time Dynamic Time Wake system from S5 when set to Fixed time Wake up hour Select 0 23 For example enter 3 for 3am and 15 for 3pm 0 Wake up minute Select 0 59 0 Wake up second Select 0 59 0 ...

Страница 141: ...http www tyan com 141 Wake system from S5 when set to Dynamic time Wake up minute increase Select 1 5 1 ...

Страница 142: ...http www tyan com 142 5 3 14 Super IO Configuration Super IO Chip Read only ...

Страница 143: ...le or Disable Serial Port COM Enabled Disabled Device Settings Read only Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 3 4 5 6 7 10 11 12 IO 2E8h IRQ 3 4 5 6 7 10 11 12 ...

Страница 144: ...le or Disable Serial Port COM Enabled Disabled Device Settings Read only Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 3 4 5 6 7 10 11 12 IO 2E8h IRQ 3 4 5 6 7 10 11 12 ...

Страница 145: ... Control Automatic Manual Full Speed NOTE PWM Minimal Duty Cycle menu is available when Fan Speed Control is set to Manual PWM Minimal Duty Cycle PWM Minimal Duty Cycle 30 BMC Alert Beep Enable Disable BMC Alert Beep Off On PMBus Support PSU Status Monitor support or not Enabled Disabled ...

Страница 146: ...http www tyan com 146 Greenwell Enable or Disable Advanced System Power Saving Disabled Enabled Number of PSU User can select PSU number for needed 1 1 1 ...

Страница 147: ...http www tyan com 147 5 3 15 1 Sensor Data Register Monitoring Read only ...

Страница 148: ...http www tyan com 148 5 4 Chipset Menu North Bridge System Agent SA Parameters South Bridge South Bridge Parameters ...

Страница 149: ...Configuration Memory Configuration Memory Configuration Parameters Graphics Configuration Graphics Configuration DMI OPI Configuration Control various DMI functions PEG Port Configuration PEG Port Options VT d VT d capability Enabled Disabled ...

Страница 150: ...http www tyan com 150 ...

Страница 151: ...ory Configuration Submenu Maximum Memory Frequency Maximum Memory Frequency selections in Mhz Valid values should match the refclk i e devide by 133 or 100 Auto 2133 2400 2666 ECC Support Enable disable DDR ECC support Enabled Disabled ...

Страница 152: ...http www tyan com 152 5 4 1 2 Graphics Configuration Submenu Primary Display Select which Graphics device should be Primary Display Auto PEG PCH PCIe ...

Страница 153: ...3 DMI OPI Configuration Submenu DMI Max Link Speed Set DMI Speed Gen1 Gen2 Gen3 Auto Gen1 Gen2 Gen3 DMI Link ASPM Control Enable Disable the control of Active State Power Management on SA side of the DMI Link Disabled L0s L1 L0sL1 ...

Страница 154: ...uto Disabled Enabled Max Link Speed Configure PEG 0 1 0 Max Speed Auto Gen1 Gen2 Gen3 Max Link Width Force PEG link to retrain to x1 2 4 8 Auto Force x1 Force x2 Force x4 Force x8 ASPM Control ASPM support for the PEG 0 This has no effect if PEG is not the currently active device Disabled Auto ASPM L0s ASPM L1 ASPM L0sL1 ...

Страница 155: ...1 Force x2 Force x4 Force x8 ASPM Control ASPM support for the PEG 1 This has no effect if PEG is not the currently active device Disabled Auto ASPM L0s ASPM L1 ASPM L0sL1 De emphasis control PEG 1 Configure the De emphasis control on PEG 6 dB 3 5 dB PEG0 Max Payload size Select PEG0 Max Payload Size Choose Auto Default Device Capability or force to 128 256 Bytes Auto 128 256 TLP PEG1 Max Payload ...

Страница 156: ...vice Options Settings PCI Express Configuration PCI Express Configuration settings DeepSx Power Policies Configure the DeepSx Mode configuration Disabled Enabled in S4 S5 Restore AC Power Loss Select AC power state when power is re applied after a power failure Power Off Power On Last State ...

Страница 157: ...SATA controller s operate AHCI RAID Serial ATA Port 0 SATADOM1 Serial ATA Port 1 SATADOM2 Serial ATA Port 2 Serial ATA Port 3 Serial ATA Port 4 Serial ATA Port 5 Read only Hot Plug Designates this port as Hot Pluggable Disabled Enabled SATA Device Type Identify the SATA port is connected to Solid State Drive or Hard Disk Drive Hard Disk Drive Solid State Drive ...

Страница 158: ...m 158 5 4 2 2 PCI Express Configuration Submenu DMI Link ASPM Control The control of Active State Power Management of the DMI Link Auto Disabled L0s L1 L0sL1 PCI Express Root Port 1 9 21 PCI Express Root Port Settings ...

Страница 159: ... Express Root Port Enabled Disabled ASPM 0 Set the SPM Level Force L0s Force all links to L0s State Auto BIOS auto configure DISABLE Disables ASPM Disabled L0s L1 L0sL1 Auto L1 Substates PCI Express L1 Substates settings Disabled L1 1 L1 1 L1 2 PCIe Speed Configure PCIe Speed Auto Gen1 Gen2 Gen3 ...

Страница 160: ...led FRB 2 Timer timeout Enter value Between 3 to 6 min for FRB 2 Timer Expiration value 3 minutes 4 minutes 5 minutes 6 minutes FRB 2 Timer Policy Configure how the system should respond if the FRB 2 Timer expires Not available if FRB 2 Timer is disabled Do Nothing Reset Power Down Power Cycle OS Watchdog Timer ...

Страница 161: ...oot Watchdog Timer Not available if OS Boot Watchdog timer is disabled 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog timer is disabled Do Nothing Reset Power Down Power Cycle BMC Logo Enable or Disable BMC Logo Enabled Disabled System Event Log Press Enter to change the ...

Страница 162: ...ents is set to Disabled the following items are read only Erase SEL Choose options for erasing SEL No Yes on next reset Yes on every reset When SEL is Full Choose options for reactions to a full SEL Do Nothing Erase Immediately Log EFI Status Codes Disable the logging of EFI Status Codes or log only error code or only progress code or both Disabled Both Error Code Progress Code ...

Страница 163: ...eters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Server Management Port 2 Enable Disable BMC Share Nic Enabled Disabled Configure IPV6 Support Server Management Port 1 IPV6 Support Enable or Disable LAN1 IPV6 Support Enabled Disabled ...

Страница 164: ... Disable LAN1 IPV6 Support Enabled Disabled Configuration Address Source Select the configure LAN channel parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp ...

Страница 165: ...window will pop out to ask for confirmation User Password Set user password in the Create New Password window After you key in the password the Confirm New Password window will pop out to ask for confirmation Security Frozen Mode Enable or disable HDD security freeze lock Disable to support secure erase function Disabled Enabled Secure Boot Customizable Secure Boot settings ...

Страница 166: ...m reset Disabled Enabled Secure Boot Mode Secure Boot mode options Standard or Custom In Custom mode Secure Boot Policy variables can be configured by a physically present user without full authentication Custom Standard Restore Factory Keys Force System to User Mode Install factory default Secure Boot key databases Reset to Setup Mode Delete all Secure Boot key databases from NVRAM Key Management...

Страница 167: ...http www tyan com 167 Enables expert users to modify Secure Boot Policy variables without full authentication ...

Страница 168: ...http www tyan com 168 5 6 1 1 Restore Factory Keys Restore Factory Keys Press Yes to proceed No to cancel ...

Страница 169: ...http www tyan com 169 5 6 1 2 Reset to Setup Mode Reset to Setup Mode Deleting all variables will reset the System to Setup Mode Do you want to proceed Press Yes to proceed or No to cancel ...

Страница 170: ...roceed No to cancel Reset to Setup Mode Deleting all variables will reset the System to Setup Mode Do you want to proceed Press Yes to proceed or No to cancel Export Secure Boot variables Copy NVRAM content of Secure Boot variables to files in a root folder on a file system device Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 Hash certificate of a PE image into Authoriz...

Страница 171: ...I Variable 3 EFI EFI COFF Image SHA256 Key source Factory External Mixed Update Append Key Exchange Keys Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI EFI COFF Image SHA256 Key source Factory External Mixed Update Append Authorized Signatures Enr...

Страница 172: ...ry Defaults or load certificates from a file 1 Public Key Certificate a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI EFI COFF Image SHA256 Key source Factory External Mixed Update Append OsRecovery Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate a EFI_SIGNATURE_LIST b EFI_CERT_X509 D...

Страница 173: ...onds to wait for setup activation key 65535 0xFFFF means indefinite waiting 1 Bootup NumLock State Select the keyboard NumLock state On Off Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Boot Option 1 5 Sets the system boot order Device Name Disabled ...

Страница 174: ...ror Wait for ESC key to be pressed if error occurs Enabled Disabled USB Device BBS Priorities Set the order of the legacy devices in this group Hard Drive BBS Priorities Set the order of the legacy devices in this group Add New Boot Option Add a new EFI boot option to the boot order Delete Boot Option Delete an EFI boot option from the boot order ...

Страница 175: ...http www tyan com 175 5 7 1 USB Device BBS Priorities Boot Option 1 Sets the system boot order Device Name Disabled ...

Страница 176: ...http www tyan com 176 5 7 2 Hard Drive BBS Priorities Boot Option 1 Sets the system boot order Device Name Disabled ...

Страница 177: ...Add New Boot Option Add boot option Specify name for new boot option Path for boot option Enter the path to the boot option in the format fsx path filename efi BOOK16G 14GB HDD SATA 96MB Create Creates the newly formed boot option ...

Страница 178: ...http www tyan com 178 5 7 4 Delete Boot Option Delete Boot Option Remove an EFI boot option from the boot order Select one to delete UEFI Built in EFI Shell ...

Страница 179: ... system setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of the setup options Discard Changes Discard changes done so far to any of the setup options Restore Defaults ...

Страница 180: ...w tyan com 180 Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options ...

Страница 181: ... 6 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard please check the TYAN web site at http www tyan com NOTE Please be aware that by flashing your BIOS you agree that in the event of a BIOS flash failure you must contact your dealer for a replacement BI...

Страница 182: ... 0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Not used Progress Codes 0x01 Power on Reset type detection soft hard 0x02 AP initialization before microcode loading 0x03 North Bridge initialization before microcode loading 0x04 South Bridge initialization be...

Страница 183: ...zation is started 0x1A Pre Memory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initialization South Bridge module specific 0x1C Pre Memory South Bridge initialization South Bridge module specific 0x1D 0x2A OEM pre memory initialization codes 0x2B Memory initialization Serial Presence Detect SPD data reading 0x2C Memory initialization Memory presence detecti...

Страница 184: ...valid memory type or incompatible memory speed 0x51 Memory initialization error SPD reading has failed 0x52 Memory initialization error Invalid memory size or memory modules do not match 0x53 Memory initialization error No usable memory detected 0x54 Unspecified memory initialization error 0x55 Memory not installed 0x56 Invalid CPU type or speed 0x57 CPU mismatch 0x58 CPU self test failed or possi...

Страница 185: ...valid recovery capsule 0xFB 0xFF Reserved for future AMI error codes PEI Beep Codes of Beeps Description 1 repeatedly Memory not installed 1 Memory was installed twice InstallPEIMemory routine in PEI Core called twice 2 Recovery started 3 DXEIPL was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available DXE Phase Status Code Description...

Страница 186: ...x73 South Bridge DXE initialization South Bridge module specific 0x74 South Bridge DXE initialization South Bridge module specific 0x75 South Bridge DXE initialization South Bridge module specific 0x76 South Bridge DXE initialization South Bridge module specific 0x77 South Bridge DXE initialization South Bridge module specific 0x78 ACPI module initialization 0x79 CSM initialization 0x7A 0x7F Reser...

Страница 187: ...ot event 0xAF Exit Boot Services event 0xB0 Runtime Set Virtual Address MAP Begin 0xB1 Runtime Set Virtual Address MAP End 0xB2 Legacy Option ROM initialization 0xB3 System Reset 0xB4 USB hot plug 0xB5 PCI bus hot plug 0xB6 Clean up of NVRAM 0xB7 Configuration Reset reset of NVRAM settings 0xB8 0xBF Reserved for future AMI codes 0xC0 0xCF OEM BDS initialization codes DXE Error Codes 0xD0 CPU initi...

Страница 188: ...failed 7 Reset protocol is not available 8 Platform PCI resource requirements cannot be met ACPI ASL Checkpoints Status Code Description 0x01 System is entering S1 sleep state 0x02 System is entering S2 sleep state 0x03 System is entering S3 sleep state 0x04 System is entering S4 sleep state 0x05 System is entering S5 sleep state 0x10 System is waking up from the S1 sleep state 0x20 System is waki...

Страница 189: ... to M1283G24 BP12E 4 SATA SAS Backplane BP Board System Fan Connect to M1283G24 BP12E 4 Fan1 FAN1 Fan2 FAN2 Fan3 FAN3 N A N A Fan5 FAN5 Fan6 FAN6 B5556G24EV4HR 2T System Fan to M1283G24 BP12E 4 SATA SAS Backplane BP Board System Fan Connect to M1283G24 BP12E 4 Fan1 FAN1 Fan2 FAN2 Fan3 FAN3 N A N A N A N A Fan6 FAN6 ...

Страница 190: ... to Mini SAS Cable SATA0_3 J76 Fan Cable J29 J39 3 Control Cable and USB Cable Front Panel Board FPB to S5556 MB M1713G24 FPB Connect to S5556 Control Cable J3 J32 USB Cable J34 J74 4 Chassis Intrusion Cable Chassis Intrusion Cable Chassis Connect to S5556 Intrusion Cable J33 5 SATA Cable 2 5 fixed SSD to S5556 MB Chassis Connect to S5556 SATA1 J19 SATA0 J16 ...

Страница 191: ...5556 MB M1620G24E D PDB Connect to S5556 2x12P CABLE PWR1 PWR1 2x4P CABLE PW2 PW2 2x4P CABLE PW5 External GPU Card N SKU PSMI CABLE PW1 J50 M1620 PDB to M1283 Backplane BP Board M1620G24E D PDB Connect to M1283G24 BP12E 4 B4P CABLE PW1 PW4 B4P CABLE PW2 PW3 ...

Страница 192: ...http www tyan com 192 NOTE ...

Страница 193: ...ard A table of BIOS Temp sensor name explanation is also included for readers reference Figure 1 Sensor Location NOTE The red spot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the fan speed rpm 2 Temp Sensor refer to Figure 1 Sensor Location They detect the system temperature around ...

Страница 194: ...http www tyan com 194 BIOS Temp Sensor Name Explanation ...

Страница 195: ...DIM_CH_B SYS_AIR_INLET Temperature of SYS_AIR_INLET Area X550_TEMP Temperature of the X550 Chipset GPU_CORE0_TEMP Temperature of GPU_CORE0 optional available if GPU is installed GPU_CORE1_TEMP Temperature of GPU_CORE1 optional available if GPU is installed SYS_FAN_1 Fan speed of SYS_FAN_1 SYS_FAN_2 Fan speed of SYS_FAN_2 SYS_FAN_3 Fan speed of SYS_FAN_3 SYS_FAN_4 Fan speed of SYS_FAN_4 SYS_FAN_5 F...

Страница 196: ...http www tyan com 196 NOTE ...

Страница 197: ...0920 411T59000026 M5556 L16 2F Riser Card Left FRU RC 0240 5411T5410002 M7081 R8 1L Riser Card Right HDD BP FRU BP 9260 5411T5650029 HDD backplane FRU M1283G24 BP12E 4 1 for GT24E B5556 Slide Rail Kit CRAL 0034 452T15200001 Slide Rail Kit CEAR 0050 340740900010 Mounting Ear Kit Cable FRU CS 0330 332810000514 TF POWER CORD SBU US 125 V 16 AWG 1 31mm 1800mm AC PWR CORD CCBL 0300 332810000281 TF PWR ...

Страница 198: ...8 FRU CS 0530 422T42300003 POWER CABLE 2 4P M P4 2 2 4P M P4 2 L 600MM CCBL 033T 422795500005 SATA CABLE SAS WIRE 550MM for internal SSD Air Duct FRU TA 0120 340T59000005 CPU AIR DUCT FRU TA 0130 342T59000005 GPU AIR DUCT ...

Страница 199: ...r expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find their latest software and operating system components to keep their systems runni...

Страница 200: ...roper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manufacturer for a Return Merchandise Authorization RMA number The RMA number should be prominently displayed on the outside of the shipping carton and the package should be mailed prepaid TYAN will pay t...

Отзывы: