52
http://www.TYAN.com
6.
Reboot the system and enter the FastBuild Utility main menu.
7.
Select
5
to rebuild the array.
FastBuild ™ Utility 1.xx © 199x- 200x Promise Technology, Inc.
[Rebuild Array Menu]
Array No RAID Mode
Total Drv
Capacity (MB)
Status
Array 1
Mirror
2
16126
Critical
Array 2
——
——
——
——
Array 3
——
——
——
——
Array 4
——
——
——
——
[Keys Available]
[
↑
] Up [
↓
] Down [ESC] Exit [Enter] Select
8.
Highlight the array with “Critical” status and press
Enter
.
FastBuild ™ Utility 1.xx © 199x- 200x Promise Technology, Inc.
[Rebuild Array Menu]
Array No
RAID Mode
Total Drv
Status
Array 2
Mirror
2
Critical
Stripe Block: Not Available
[Select Drive for Rebuild]
Channel:ID
Drive Model
Capacity (MB)
1: Slave
QUANTUMCR8.4A
8063
[Keys Available]
[
↑
] Up [
↓
] Down [ESC] Exit [Enter] Select
9.
Highlight the replacement drive under
[Select Drive for Rebuild]
.
10.
Press
Enter
. All existing data on the replacement drive will be written over with mirrored
information from the array drive. A progress bar will appear on the screen.
11.
Reboot the system when the process is completed.