![TXT LASER TXT-HJ Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/txt-laser/txt-hj/txt-hj_user-manual_1185132040.webp)
Laser Welding Machine
Address: 18 South Liu Fang Yuan Road,Sintec Industrial Park, Wuhan Hubei, 430205 PR China
Tel: 0086 27 65523998 Mobile/WhatsApp/Wechat:0086-17371095681
Web:http://www.txtlaser.com/ ; E-mail: [email protected]
第
40
页
7.2 HMI operation introduction
7.2.1 Parameter settings
:
Parameter settings include: main page, system parameters, wire feeding
parameters, and diagnostic page settings.
【
Main
】
: Used to set the related parameters of laser, swing and process
library during welding.
Process library: Click the white box area of the process library to select the set
process library parameters.
Welding mode: Set welding mode: continuous, pulse mode.
Laser Power: Set the peak power of the laser during welding.
Laser Frequency: Set the frequency of the laser PWM modulation signal.
Duty cycle: Set the duty cycle of the PWM modulation signal, the setting range
is 1% to 100%.
Swing frequency: Set the frequency of motor swing.
Swing Length: Set the width of motor swing.
Wire feeding speed: Set the wire feeding speed during welding.
Laser emission time: Laser emission time in spot welding mode.
Spot welding mode: Click to enter the spot welding laser emission mode.
7.2.2
【
System parameters
】:
It is used to set the basic parameters of the
device, generally configured by the manufacturer, and you need to enter a
password before entering the page.
The system entry password is: 666888 six digits.
Pulse On Time: Light output time in pulse mode.
Pulse Off Time: Light off time in pulse mode.
Ramp up time: It is used to set the time for the laser analog voltage to slowly