7;5;6\VWHPV,QF
Manual 7-9547-1 12/09/14 Page 36
Initial Setup
When the TTA system is installed the SNMP fea-
ture should be setup for proper communications.
There are several steps required for proper setup
of the SNMP feature as listed below.
1) Connect a laptop directly to the TTA deck. Refer
to Appendix A for detailed instructions on how
to make a direct connection. The TTA deck is
shipped from the factory setup for static IP
addressing with a default IP address of
“192.168.1.1” and the factory default subnet
mask is
“255.255.255.0”
. Change the factory
default IP address of the TTA deck to one pro-
vided by your IT department.
2) Use the Network Configuration to setup the
DHCP as either active or inactive. When DHCP
is inactive the deck will be using a static IP and
the user must enter values for IP address, net-
mask, and gateway.
3) Use the SNMP Configuration to enter up to
three device addresses. These are addresses
where the SNMP feature will send traps when-
ever a qualifying event takes place. Qualifying
events are listed in the section of this manual
under the title Trap Receiver GUI.
4) Load trap receiver software into the destination
SNMP computer/manager(s), so it will be able
to decipher the SNMP traps. The trap receiver
software (called a MIB file) will be supplied by
Bird Technologies as a downloadable file.
Figure 25:
SNMP Configuration menu without password access.
Figure 26:
SNMP Configuration menu with password access.
Содержание 434B-83H-01-M-110/48
Страница 12: ...7 5 6 VWHPV QF Manual 7 9547 1 12 09 14 Page 12 Figure 5 Functional block diagram of the system...
Страница 18: ...7 5 6 VWHPV QF Manual 7 9547 1 12 09 14 Page 18 Figure 9 Base Control Unit MCU system installation guidelines...
Страница 19: ...7 5 6 VWHPV QF Manual 7 9547 1 12 09 14 Page 19 Figure 10 System installation guideline notes...
Страница 44: ...8625 Industrial Parkway Angola NY 14006 Tel 716 549 4700 Fax 716 549 4772 sales W U com www W U com...