Ref.  No.:  SCDD-090011 

 

 

   

TWINBIRD CORPORATION 

http://fpsc.twinbird.jp

 

(4/17) 

(9)  FPSC モジュールを火の中に放り込まないで下さい。内部のガスが膨張し、爆発する恐れがあります。 

Warning:  Placing  the  FPSC  Module  into  fire  or  excessive  heat  could  cause  expansion  of  the 

contained gas and explosion. 

(10) コードを強く引っ張らないで下さい。断線し、故障の原因となります。 

Do not put excessive strain on the electrical cords. It could cause damage to the wire and cause 

the FPSC Module stop operating. 

(11) FPSC モジュールの放熱フィンや基板の部品は、運転中及び停止直後は高温になっていることがあり

ます。素手で触わらないでください。火傷の恐れがあります。 

To avoid the danger of burns, avoid touching the heat reject fin and certain parts on PCB with your 

bare hands during or immediately after operation. 

(12) FPSC モジュールの吸熱部及びその周辺は、運転中及び停止直後は低温になっています。素手で触

わらないでください。凍傷の恐れがあります。 

To avoid the danger of frostbite, avoid touching the cold side and its immediate surroundings with 

your bare hands during or immediately after operation. 

(13) FPSC モジュールの吸熱部及びその周辺は、霜や露がつかないように断熱してください。また、単体で

の動作確認などで霜や露が付着した場合は、運転を停止させた後にやわらかい布などでふき取ってく

ださい。着霜や結露は冷却能力の低下につながり、融けた霜や露が電源コードや内部の機構部品に

流れ落ちると、電気回路がショートして故障したり、腐食の原因になったりしますので、十分ご注意くだ

さい。 

Please  provide  thermal  insulation  around  cold  side  to  prevent  frost  and  dew  condensation.  If 

conditions require that you need to operate the FPSC Module without thermal insulation, the cold 

side may develop a coating frost or water. If this occurs, please clean the cold side with a soft cloth. 

Having frost or condensation on the cold side surface can cause an apparent reduction of cooling 

capacity. Also, if water drips down on a power cord or inner mechanical parts as it defrosts, it could 

cause a short circuit or corrosion. 

(14) FPSC モジュールの吸熱部は薄いステンレス板で形成されており、内部は精密構造になっております

ので、熱交換器の取り付けの際など、吸熱部に強い力を加えないで下さい。故障の原因となります。 

Failure of the FPSC Module could result from subjecting the cold side to a strong force. It is made 

of thin stainless steel sheet surrounding a precision structure. 

(15) FPSC 内部に高圧のガスが封入されていますので、廃棄の際は弊社までご相談ください。 

The Stirling cooler uses a high pressure gas inside, please contact Twinbird if you intend to scrap 

the Stirling cooler. 

 

 

 

 

 

 

Содержание SC-UB04

Страница 1: ...Ref No SCDD 090011 TWINBIRD CORPORATION http fpsc twinbird jp 1 17 Operation Manual Model SC UB04 Name 40W FPSC H 40W FPSC Module H SC TWINBIRD CORPORATION SC Business Operation...

Страница 2: ...infringement which could result in legal action against the infringing party 10 USA REEXPORT CONTROL CCL ECCN 6A002 d 2 a Cryocoolers for Optical sensors 2008 1 The following regulations shall apply t...

Страница 3: ...e FPSC Module To avoid the possibility of damaging to internal parts by overheating the FPSC Module do not apply heating elements directly to the cold side 4 Use caution when handling the Heat Reject...

Страница 4: ...tion 13 FPSC Please provide thermal insulation around cold side to prevent frost and dew condensation If conditions require that you need to operate the FPSC Module without thermal insulation the cold...

Страница 5: ...90 x H 280 mm 2 Weight Approximately 3 kg 3 Refrigerant He Helium 4 Amount of Refrigerant 2 5 g 5 Inside Pressure of Stirling Cooler 2 6 Mpa 6 Power Source DC 12 V for Drive PCB 7 Cooling Capacity 40W...

Страница 6: ...f No SCDD 090011 TWINBIRD CORPORATION http fpsc twinbird jp 6 17 Graph of Cooling Capacity Cold Side Temperature Condition Ambient Temperature 25 Cooling Capacity W 60 40 20 0 20 0 10 20 30 40 50 60 7...

Страница 7: ...Ref No SCDD 090011 TWINBIRD CORPORATION http fpsc twinbird jp 7 17 Main Size mm...

Страница 8: ...N OFF 3 CN8 AC 2 0 8 5 V 4 1 0 3 1 0 High Low 2 1 0 4 1 1 0 High Low 5 1 High Low 6 2 High Low 7 8 0V 9 5V DC 5 0 V 10 50 mA CN2 JST B2B PH K E JST PHR 2 1 2 CN6 JST B2B PH K S JST PHR 2 1 2 0 0 3 V 5...

Страница 9: ...gh Low 6 Status Alarm Normal Alarm Signal 2 Output Output High Low 7 Status Alarm Normal 8 0V 9 5V Reference Voltage Output Output Voltage DC 5 0 V 10 Output Current Capacity 50 mA CN2 JST B2B PH K E...

Страница 10: ...o the control terminal 3 FPSC FPSC DIP SW After initial start up of the FPSC the driving voltage increases in steps at a speed determined by the DIP switch settings 4 FPSC 7A Controls output voltage i...

Страница 11: ...ignal is out of the allowed range Power source CN1 Connect power source to power input terminal CN1 No Item Specification 1 Rating voltage DC 12 V 2 Allowable voltage DC 10 8 13 2 V DC 12 V 10 3 Maxim...

Страница 12: ...DC 5V Low GND 47k DC 5V Signal input terminal is connected to 5V DC through 47 k ohm resistor on PCB Setting of output CN7 Pin 1 CN7 Pin 2 3 FPSC Output voltage is decided by input voltage CN7 Pin 1 o...

Страница 13: ...V 2 sec 0 1 V 5 sec 0 1 V 10 sec 0 1 V 15 sec 0 1 V 20 sec 0 1 V 25 sec 0 1 V 30 sec SW1 SW1 value 1000 1001 1010 1011 1100 1101 1110 1111 Ramp speed of output voltage 0 1 V 35 sec 0 1 V 40 sec 0 1 V...

Страница 14: ...CN2 FPSC SW2 FPSC 54 0010 FPSC SC UB04 FPSC 65 FPSC 65 The PCB detects insufficient heat rejection for FPSC using connected warm side thermistor connected to CN2 Limitation of temperature can be set a...

Страница 15: ...s power supply to the FPSC will be stopped and an emergency signal will be output from the signal output terminal CN7 5 SW2 Temperature sensor at warm side has reached the limit temperature set by SW2...

Страница 16: ...on for cancellation of the alarm signal 1 output When the temperature of the sensor on the warm side goes down 5 deg C lower than the temperature set by DIP switch Alarm signal 2 1 2 Situation for ala...

Страница 17: ...C E mail sc twinbird co jp Tel 0256 92 6173 Fax 0256 93 6168 959 0292 2084 2 Contact TWINBIRD CORPORATION SC Business Operation E mail sc twinbird co jp Phone 81 256 92 6173 Facsimile 81 256 93 6168 A...

Отзывы: