6

COOL DOWN CYCLE

NIGHT MODE

After the heater has ran the fan will continue to run for a period 

of time to cool down the internal parts.  

Toggle between night mode which reduces the halogen and 

reduces the brightness of the heater for night use.

“     ” display show when turn off the halogen.

This product is equipped with a safer Plug; an advanced safety 

device that helps detect electrical fires caused from faulty outlets. 

Overloading of outlet, adapters and surge protectors may cause 

overheating, damage, and increase risk of fires. Safer Plug 

continuously monitors the temperature in the plug and outlet 

and will turn off the heater to prevent unsafe outlet overheating.

If the Safer Plug cuts the power due to unsafe conditions it will 

show an “      ”message on the screen. If this occurs the Safer 

Plug has prevented a potentially unsafe condition.

To reset the device if this occurs, first allow the plug to cool down. 

Once the plug has cooled down, unplug the device and wait 

5 seconds, then plug back in and continue to use normally.

If the Safer Plug continues to activate your outlet may be faulty. 

Check your heater cord and plug connections. Faulty wall outlet 

connections or loose plugs can cause the outlet or plug to 

overheat. Be sure the plug fits tight in the outlet. Heaters draw 

more current than small appliances, overheating of the outlet may 

occur even if it has not occurred with the use of other appliances.  

During use check frequently to determine if your plug outlet or 

faceplate is HOT!  If so, discontinue use of the heater and have a 

qualified electrician check and/or replace the faulty outlet(s).

SAFER  PLUG

SAFER  SENSOR

OPERATION INSTRUCTIONS

FUNCTION

ICON

DESCRIPTION

Patent Pending

Patent Pending

This product is equipped with a Safer Sensor; an advanced safety 

device that helps prevent heaters from being accidently covered or 

blocked causing a potentially unsafe condition.

The SAFER  SENSOR detects if an object is too close to the front 

of the heater potentially obstructing the air outlet. If blocked, the 

SAFER SENSOR icon on the control panel will flash, the heater 

will beep continuously, and then shut off.  Once the object has 

been moved, the icon will stop flashing, the beeping will cease, 

and the heater will turn back on.

To disable the Proximity Sensor safety function press and hold 

the ECO MODE button for 10 seconds. Once disabled the SAFER 

SENSOR icon will remain lit indicating it is disabled. Repeat this 

step to re-enable the function.

Содержание 19QH8000-W500

Страница 1: ...MODEL 19QH8000 W500 INSERT MODEL 19QI071ARA The safest and most advanced heating technology available Smart HEATER ...

Страница 2: ...le 19 This heater may include a visual alarm to warn that parts of the heater are getting excessively hot If the alarm flashes immediately turn the heater off and inspect for any objects on or adjacent to the heater that may cause high temperatures DO NOT OPERATE THE HEATER WITH THE ALARM FLASHING SAVE THESE INSTRUCTIONS 1 Read all instructions before using this appliance 2 This appliance is hot w...

Страница 3: ...ICADO POR CSA C22 2 N º 46 1 866 661 1218 www tsicustomerservice com SN AB 12345 A Date Code Code de Date Código Fecha PRODUCT SPECIFICATIONS VOLTAGE 120VAC 60 Hz AMPS 12 5 Amps WATTS 1500 Watts 1 The serial number is located on the back of the heater The serial number is necessary for product warranty registration and customer service 2 Go to www tsicustomerservice com for product warranty regist...

Страница 4: ...trol or the control panel Control Panel The relevant icon will illuminate on the display to indicate when a function is activated The icon will dim out when a function is deactivated The display backlight will dim a few seconds after a command has been set Remote Control OPERATION INSTRUCTIONS ...

Страница 5: ...sing the Power button again the heater will turn on at the same settings Pressing and holding the POWER button on the control panel for 3 seconds will switch between F and C The display will count down from 20 seconds before turning off the heater Press TIMER button will turn on or off timer settings There are 10 timer settings and OFF that can be selected OFF 00 30min 1Hour 2H 3H 4H 5H 6H 7H 8H 9...

Страница 6: ... and plug connections Faulty wall outlet connections or loose plugs can cause the outlet or plug to overheat Be sure the plug fits tight in the outlet Heaters draw more current than small appliances overheating of the outlet may occur even if it has not occurred with the use of other appliances During use check frequently to determine if your plug outlet or faceplate is HOT If so discontinue use o...

Страница 7: ...tStar To connect the Smart Star app with the heater 1 Turn on the heater 2 Make sure your iOs or Android device has bluetooth enabled if you are unsure how to enable bluetooth on your device consult the users manual or technical support from the device manufactuer 3 With the heater turned on and the device within 20 feet line of sight to the heater open the Smart Star app The module will automatic...

Страница 8: ... hold button down while plugging unit back in Once unit is plugged back in continue to hold button for 5 seconds and then release Turn unit back on and temperature should flash 72 degrees then display the ambient room temperature Not reaching set temperature Unit is designed to be used as a supplemental heat source in conjunction with a primary heat source The heater is taking a long time to reach...

Страница 9: ...ith a clean soft cloth DO NOT use brass polish or household cleaners as these products will damage the metal trim Citrus oil based products can be obtained at supermarkets or hardware stores WARNING Electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire electrical shock and injury to persons WARNING Disconnect power before attempt...

Страница 10: ... experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The device must not be co located or operating in conjunction with any other antenna or tra...

Страница 11: ... user assumes all other risks if any including the risk of any direct indirect or consequential loss or damage arising out of the use or inability to use the product except as provided by law 7 All other warranties expressed or implied with respect to the product its components and accessories or any obligations liabilities on the part of the manufacturer are hereby expressly excluded 8 The manufa...

Страница 12: ...Customer Service www tsicustomerservice com 1 866 661 1218 Twin Star International Inc Delray Beach FL 33445 Made in China Printed in China ...

Отзывы: