ARCMASTER 401MST POWER SOURCE
Manual 0-5287
5-3 POWER SOURCE PROBLEMS AND ROUTINE SERVICE REQUIREMENTS
Code
Error
Cause
Possible Remedy
E08-11
V/I Acquisition
Voltage/current measuring
systems faulty
Take to an accredited Tweco Service
Center for repair.
E08-13
CAN Identification
Unknown device connected
Check connected devices and CAN
connections
E09
Output Voltage
Voltage measuring system
faulty.
Torch is touching work piece
Take to an accredited Tweco Service
Center for repair.
Raise Torch from contact with work
piece.
E12
Power Section
Power section start-up faulty.
Torch is touching work piece
Take to an accredited Tweco Service
Center for repair.
Raise Torch from contact with work
piece.
E13
Temperature Sensor
Temperature sensor not ready
for operation
Take to an accredited Tweco Service
Center for repair.
E14
Supply Voltage
Internal supply voltage too low Check mains voltages
E15
Current Detection
Error during current measure-
ment
Take to an accredited Tweco Service
Center for repair.
E18
Overload Protection
Safety switch device to protect
elec trical components
Take to an accredited Tweco Service
Center for repair.
E22
Mains Undervoltage
Mains voltage on power unit is
too low
Check mains voltages
E25
Idle Generator
Idle generator faulty
Take to an accredited Tweco Service
Center for repair.
E30
Error Configuration
Faulty or wrong pc-board,
wrong software system
installed
Take to an accredited Tweco Service
Center for repair.
E31
Communications Fault
CAN bus communication
faulty
Switch the equipment off and on
again
E32
FPGA
FPGA faulty
Take to an accredited Tweco Service
Center for repair.
E33
Power Section
Power module not symmetri-
cal
Take to an accredited Tweco Service
Center for repair.
E34
Fans
Fan current faulty
Take to an accredited Tweco Service
Center for repair.
E39
Protective Earth Conductor
Monitoring
Fault current to protective
earth con ductor
Connect the welding earth lead
E40
Voltage detection
Voltage measurement faulty at
the socket
Take to an accredited Tweco Service
Center for repair.
E47
Undefined Mains
Mains voltage between per-
mitted ranges
Check mains
Table 5-2 Power Source Error Messages
Содержание ARCMASTER 401MST
Страница 6: ......
Страница 24: ...ARCMASTER 401MST POWER SOURCE SAFETY INSTRUCTIONS AND WARNINGS 1 18 Manual 0 5287 This Page Intentionally Blank...
Страница 30: ...ARCMASTER 401MST POWER SOURCE INTRODUCTION 2 6 Manual 0 5287 This Page Intentionally Blank...
Страница 56: ...ARCMASTER 401MST POWER SOURCE INSTALLATION OPERATION AND SETUP 3 26 Manual 0 5287 This Page Intentionally Blank...
Страница 72: ...ARCMASTER 401MST POWER SOURCE This Page Intentionally Blank BASIC WELDING GUIDE 4 16 Manual 0 5287...
Страница 80: ...ARCMASTER 401MST POWER SOURCE APPENDIX A 2 Manual 0 5287 This Page Intentionally Blank...
Страница 82: ...This Page Intentionally Blank...