12
EASY 1-MT
Issued 05/00
TROUBLESHOOTING GUIDE (continued)
Faults
The powder does not fluidize.
The gun does not spraypow-
der in spite of the control
unit being switched on and
the trigger being pressed
Causes
No compressed air present
- Reducing valve closed
- Reducing valve defect
No compressed air present
- Injector, check valve or
nozzle
on the injector,
powder hose
or
gun
clogged
- Valve in the injector clogged
- Valve not fitted
- Fluidizing does not function
No conveying air:
- Reduction valve defect
- Solenoid valve defect
- Electronic board defect
Remedies
Connect the equipment to the
compressed air supply
Open
Replace
Connect the equipment to the
compressed air supply
Clean corresponding part
Replace
Fit valve
See above
Replace
Replace
Send in for possible repair