7
EASY 1-MT
Issued 05/00
DAILY START UP
A) POWDER FLUIDIZING
The fluidizing of the powder is dependent on the type of powder, the
humidity of the air and the ambient temperature. The fluidizing
functions with the switching on of the control unit.
Proceed as follows:
1. Set the Airmover (if fitted) by turning the air valve
2. Open the filling cover of the powder hopper
3. Slowly increase the fluidizing air on the fluidizing air pressure
gauge.
The powder should only “boil” lightly, but evenly. If necessary,
stir the powder with a stick.
4. Fix the position of the pressure reducing valve by pressing the
knob down
5. Close the filling cover again
6. Switch the Airmover off
B) REGULATING THE POWDER OUTPUT, AND POWDER CLOUD
The powder output is dependent on the powder, and the setting of the
total air volume.
1. Switch on the control unit
2. Set the total air volume (For further information see the EasyFlow
Operating Instructions)
The total air volume is dependent on the powder hose length, the
number of turns of the hose, the hose diameter, and the object
to be coated.
The value set for the total air volume can be left as it is, as long
as the same powder hose is used. If the hose length and/or the
hose diameter are changed, then the total air volume must be
reset.
3. Select the powder output volume according to the desired
coating thickness.
The selection takes place with the aid of the Keys
+
and
–
either
on the control unit or on the rear of the powder gun.
To start, a standard setting of 60% is recommended. The total air
volume is maintained constant automatically.
4. Check the fluidizing of the powder
5. Point the powder gun into the booth and press the powder gun
trigger
6. Select the correct electrode rinsing
When using flat jet nozzles:
- Press the Key with the corresponding symbol
. The LED of
the corresponding Key illuminates.
When using round jet nozzles with air rinsed deflector plates:
- Press the Key with the corresponding symbol
. The LED of the
corresponding Key illuminates.
(continued)
SET TOTAL AIR
VOLUME
SELECT POWDER
OUTPUT VOLUME
SELECT ELECTRODE
RINSING