1.
Connect a CAT-5e cable (or better), up to 330 feet (100 meters) from each
ELR-POL input to each of the included DVI ELR-POL Sender units, as shown
below.
8
3.
Connect a DVI cable from the DVI Out port on the ELR-POL Receiver unit to
a DVI display.
4.
Connect both AC power cords from the matrix to available electrical outlets.
Connecting both AC power cords will provide redundancy should one of
the power supplies fail. It is recommended to connect each power cord to
electrical outlets on two separate circuits.
Power to the Receiver unit is delivered from the power supply in the matrix
over the CAT-5e cable using Power Over Line (POL) technology.
The Link indicator will glow bright green to indicate a solid connection
between the matrix and the Receiver unit. The Power indicator will glow
bright blue to indicate that the Receiver unit is being powered.
If either of these LED indicators are off , inspect the CAT-5 cable.
MOD-16416-DVIELR (continued)
to DVI display
DVI-ELRPOL-R
MOD-16416-ELR
CAT-5e (or better) cable up to
330 feet (100 meters)
Quick Start Guide