This manual provides warnings and procedures that are intended to inform the owner/operator of 
the hazards present when using the Tuthill Transfer Systems, TUTHILL meters and other products.  
The reading of these warnings and the avoidance of such hazards is strictly in the hands of the 
owner/operator of the equipment.  Neglect of that responsibility is not within the control of the 
manufacturer of the flow meter. 

Read this manual as well as the literature provided in your 
owner’s manual.  If you have any questions, consult with 
your full-service distributor or call the Service Department at 
Tuthill Transfer Systems, TUTHILL meters at 888-578-3258. 

Please have the following information available when you 
make inquiries, order replacement parts, or schedule ser-
vice.  If a specific meter accessory is involved, please pro-
vide the model and serial number of the accessory in ques-
tion. 

 

 

Meter Serial Number: 

____________________________ 

 

Your Full Service Distributor: 

 

 

Name:     

________________________________ 

 

 

Telephone:  

_________________________________ 

 

 

 

 

 

IN THE EVENT OF A GAS LEAK 

In the event of a large gas leak: 



Evacuate the area and notify the fire department or oth-
er appropriate authorities.

 

 

In the event of a small, contained gas leak: 



Isolate and stop the leak

 



Prevent accidental ignition

 



Prevent entrance of gas into other portions of the build-
ing.  Be aware that LPG is heaver than air and will seek 
lower levels

 



Evacuate all people from the danger zone

 



See that the gas is dispersed before resuming the busi-
ness and operations.  If in doubt, notify your local au-
thorities.

 

 

IN THE EVENT OF A GAS FIRE 

In the event of large fires or fires that are spreading: 

Evacuate the building and notify your local fire department.  
Stop the leakage only if you can safely reach the equipment. 

In the event of small, contained fires that you can safely 
control: 

Stop the leakage if you can safely reach the equipment.  
Then use the appropriate extinguisher:  Class B fire extin-
guisher, water, fog, etc. depending on the equipment.  If in 
doubt, call your local fire department. 

 

The meters non-shock maximum operating pressure is indi-
cated on the meter name plate.  The meter should never be 
operated in excess of this pressure.  Care should be taken 
to eliminate thermal and hydraulic shock conditions, so that 
they do not exceed the meters maximum working pressure. 

S A F E T Y     P R O C E D U R E S 

Содержание Sotera TS06AE71

Страница 1: ...S06AE93 __ TS06AE96 with ELNC __ TS06AE71 __ TS06AE72 __ TS06AE73 S No __________________ The flow meter shipped under this general manual has specifically ACCESSORIES REGISTER Backpressure Valve None Strainer RAD register adaptor Vapor Eliminator EMR Register Differential Valve ELNC Register TS06AS86 with thermo well TS06A LPG Anodized Aluminum Electronic Dispenser Meter TS06LPG 6 22 2012 ...

Страница 2: ...eter Maintenance 7 10 Disassembly Flow Meter 9 Inlet Check Valve 10 Strainer 10 Vapor Eliminator 10 Differential Valve 10 Parts List Meter Strainer 13 Differential Valve 11 Inlet Check Valve 11 Vapor Eliminator 11 Troubleshooting 14 SCL Pulser Assembly 15 16 Meter calibration 16 ...

Страница 3: ...nt of a large gas leak Evacuate the area and notify the fire department or oth er appropriate authorities In the event of a small contained gas leak Isolate and stop the leak Prevent accidental ignition Prevent entrance of gas into other portions of the build ing Be aware that LPG is heaver than air and will seek lower levels Evacuate all people from the danger zone See that the gas is dispersed b...

Страница 4: ...means of support It is recommended that a strainer be installed upstream of each meter to prevent damage from foreign matter such as weld slag pipe scale etc A means to calibrate and prove the meter should be provid ed during installation An easy means for diverting flow into a calibration vessel should be considered Operation Requirements Upstream lines must be maintained full to prevent air from...

Страница 5: ...ter inlet valve and allow the meter and pip ing to fill slowly by gravity Crack open the outlet valve and start the pump then slowly open the inlet valve until the system is up to pressure Open the outlet valve fully to establish full flow Check the flow rate to assure the meter is operating within specified rates The meter is not designed to operate on air but the design and materials of construc...

Страница 6: ... 5 6 2 3 5 4 EMR ground 1 The SCL is model specific and in some cases also application specific Do NOT transfer to another flow meter without consulting with Tuthill 2 Use 4 conductor shielded cable 3 Terminate shields at receiving instrument register 4 Move W1 shunt jumper to match operating voltage 5 S1 must be in Q position 6 Output signal has an internal pull up resistor 1000 Ω on each channel...

Страница 7: ...057 ELPS 2057 AC power supply barrier EL0300 5 SCL inside flow meter front cover 1 This drawing does not guarantee compliance for intrinsically safe apparatus Refer to CD1000 CD1001 and State National electrical codes 2 Terminate shields only at J1 4 3 Cable lengths are limited by entity parameters ...

Страница 8: ...ith Backlight Display 10 1 Pulse AC powered through EL2057 1 This drawing does not guarantee compliance for intrinsically safe apparatus Refer to CD1000 CD1001 and State National electrical codes 2 Cable lengths are limited by entity parameters 3 ELPS output option Install U1 R3 TB6 ...

Страница 9: ... installed in the vapor vent line to allow removal of the strainer or service on the meter The vapor release vent line must be returned to the vapor space of the supply tank and normally should not be made common with the other vapor return lines or pump by pass lines When properly installed this line must permit free flow in either direction If the vent line is closed the meter will not function ...

Страница 10: ...Discard and replace the old O ring seals if it is nicked or scratched in any way It is undamaged it can be re used Examine all fasteners make sure fasteners are not bent rusted or have pulled or burred threads The threads should all appear evenly placed If the bolts are bent check the housing and cover for flatness Use a straight edge to determine flatness Use a stone to remove any burrs on the fl...

Страница 11: ...11 Flow Meter Maintenance ...

Страница 12: ...spect the meter body for damage Use 200 grit paper to remove small scratches and blemishes if the dam age is more than superficial replace the body Inspect the post and post plate Replace if there is any wear Inspect the O ring seals and replace any damaged or brittle seals Reinstall the meter in reverse order Install a new oval gear set 17 if necessary Gears should be perpendicular to each other ...

Страница 13: ...rential valve outlet flange Remove the meter as detailed in the METER DISAS SEMBLY section Remove the back check valve assembly 11 Manually open and close the valve to assure proper operations Inspect for dirt of salt build up and clean if necessary Inspect the seals for wear or damage Replace worn or brittle seals Reassemble the valve and install in the strainer hous ing This valve is optional an...

Страница 14: ...STPL SHCS FS2801 2 1 Cover 2 4 Differential Valve CP6101 3 1 O Ring UL Buna SL3224 4 1 Valve Body 3 4 Differential Valve MP6100 5 1 O Ring UL Buna SL3132 6 1 Spring 3 4 Differential Valve MS8035 7 1 Repair Kit Piston 3 4 Differential Valve RK4000 7a 2 U Cup Seal UL Viton SL1212 U 7b 1 O Ring Sq Cut UL Buna SL3212 SQ 7c 1 Seal Retainer ST6102 7d 1 Piston Brass 3 4 Differential Valve MP4000 Item Qty...

Страница 15: ...15 Exploded View ...

Страница 16: ...14 nss nss 17 Gear Set 1 GS550CC 2 GS550CC R 18 O Ring Buna 2 SL3151 4 SL3151 R 19 Meter Body 1 MB2551 2 MB2551 20 1 4 20 x 3 25 SHCS 4 FS2911 4 FS2911 21 Dowel Pins 2 MS2001 4 MS2001 22 Cover Chamber 1 MP2574 2 MP2574 22b SCL Assembly 5V regulated 1 EL0300 5 1 3 2 EL0300 5 1 3 R SCL Assembly 6 12 V or EL0300 5 3 3 or EL0300 5 3 3 23 1 4 20 x 1 25 SHCS 4 FS1803 8 FS1803 24 Gasket Dust Cover 1 SL70...

Страница 17: ...eck pump by pass setting Faulty non functioning pump Differential vale not open or not functioning Replace valve Meter frozen due to build up of salts or frozen material Clean meter internals and inspect for damage Vapor vent line valve shut or obstruction in vapor vent line Open valve or remove obstruction Strainer dirty and plugged Clean Strainer U Cups on differential valve leaking Replace U Cu...

Страница 18: ... an ECF of 0 925 100 108 would be programmed into the SCL and the output pulse frequency would be equivalent to the se lected base resolution of 100 PPL LINEARIZER MODE If a metering device is not producing an output within the limits of accuracy required for an application the SCL may be used as a linearizer A linearizer is a device which rec ognizes the output frequency of the metering device an...

Страница 19: ...5 45 increase in the prover volume To obtain a greater increase in the prover volume S2 must be placed in the minus position and S3 and S4 rotated to the proper position to obtain the desired change in pulse resolution The opposite is true if S2 is already in the minus position at the beginning of calibration Finally Re seal the flow meter Enter date and correction on the permanent flow meter reco...

Страница 20: ...20 NOTES ...

Отзывы: