5
This label is placed on the front of the machine. The covers (doors) shall
not be opened while the machine is in operation. Proper lock-out, tag-
out procedures should be followed.
This label is placed at the process outlet. The outlet can approach
temperatures as high as 400° F (204° C).
This label is placed at the process outlet. High pressure and flow exist
at the process outlet with exposure to pressure relief valve.
3. DESCRIPTION
TABLE 1 — SPECIFICATIONS
MODEL
MAX. RPM
MAWP
psi /
bar
APPROXIMATE WEIGHT
LBS. /
KG
WITHOUT MOTOR
WITH MOTOR
400
4800
18 /
1241
824 /
374
1599 /
726
800
4000
18 /
1241
2550 /
1157
3550 /
1611
1600
3200
18 /
1241
3202 /
1453
5202 /
2360
For additional bare shaft blower information, refer to the appropriate bare shaft blower manual.
NOTE
Maximum ambient temperature is 104° F (40° C)