19
6.
Clean inside of filter base plate and housing as necessary, taking care not to sweep any debris into the
blower intake piping.
7.
Place a new or cleaned element on the filter base plate.
8.
Install filter retainer housing with the nut and washer that were removed in step 3.
9. Install Qube enclosure top panel and secure the quarter-turn fasteners.
10. Unlock the power and start your Qube.
6.3 V-BELTS
Qube incorporates an innovative, automatic V-belt tensioning system combining motor mass and spring
tension to maintain a constant and appropriate force on the V-belts, lengthening belt life. (See Figure 6)
Additionally, the automatic V-belt tension system provides for even tension on the belts throughout the
operating life of the belts, reducing wear on the belts, shafts and bearings. A visual inspection of the V-belt
drive should yield the appearance shown in Figure 7.
The Qube also has a visual
indicator for the belt tension
and is set at the factory;
however, this setting may
have changed in transit,
necessitating adjustment.
When the belt is properly
tensioned the visual indicator
(pin) is at the top position. As
the belts stretch the indicator
moves downward. When the
pin reaches the lower most
position the belt tension
should be readjusted such
that the indicator is again in
the bottom position.
It is recommended to check
belt tension monthly and make
any manual adjustments
found necessary:
1. Turn off and lock out
power to your Qube.
2. Turn top latches and
open top panel of the
enclosure.
3. Remove front door by
removing (2) bolts and
lifting door.
4. If visual indicator pin has
not reached the bottom of
the indicator slot, then the
belt(s) is (are) properly
tensioned and no
adjustments are required.
If the visual indicator pin
has reached the top of
the indicator slot then
the belt(s) needs to be
re-tensioned by following
the remaining steps.
Figure 6 - Auto Belt Tension System and visual indicator
SEE
A AND B
AT RIGHT
THE BELT IS
PROPERLY TENSIONED
WHEN THE INDICATOR
IS AT THE TOP.
WHEN THE
INDICATOR IS AT THE
BOTTOM, TIGHTEN
WHERE INDICATED.
THE BELT IS
TENSIONED WHEN
INDICATOR IS AT THE
BOTTOM
SEE A AND B AT RIGHT
SEE A AND B AT RIGHT
SEE B AT RIGHT
SEE B AT RIGHT
WHEN INDICATOR IS AT
TOP, TIGHTEN WHERE
INDICATED AND MOVE
INDICATOR DOWN
THE BELT IS TENSIONED
WHEN INDICATOR IS AT
THE BOTTOM
WHEN INDICATOR IS
AT TOP, TIGHTEN
WHERE INDICATED
TIGHTEN
HERE
TIGHTEN
HERE
TIGHTEN
HERE
DETAIL A
QUBE 800
QUBE 1600
QUBE 400
DETAIL B
DETAIL A
DETAIL B
DETAIL A