21
07
Disassembly
Manual 4804 Rev C p/n 004804 0000
OTE:
N
Verify that further disassembly is
necessary if:
•
The impeller nut and locknut are not
secure.
•
The impeller has to be replaced or
requires a major cleaning.
•
The center housing has to be
replaced. Remove it by following
steps 4 through 6. However, if a
complete pump disassembly is
required, temporarily reassemble the
impeller housing and end casing with
three or four tie-rod nuts.
Then invert the pump and continue with
steps in DE Shaft Seal on page 21.
4. Loosen and remove the impeller locknut. Then
loosen and remove the impeller nut (thin nut).
Note the threading:
KLRC-40 and 75
KLRC-125 to 950
Left Hand Thread
Right Hand Thread
CW to loosen
CCW to loosen
5. Lift off the impeller and note the direction of the
blade for reassembly.
6. Remove center housing by disassembling tie-
rod nuts at the DE end casing.
DE Shaft Seal
1. Position pump vertically on support stand,
DE up.
2. Remove DE bearing housing cap and bearing
locknut with a spanner wrench.
3. Remove DE bearing housing (with nameplate).
4. Remove the loose elastomer
À
inger, the shaft
seal seat, the double-row ball bearing, and
bearing spacer from the bearing housing.
5. Remove shaft seal as described in step 5 in
NDE Shaft Seal on page 20
.
OTE:
N
For DE shaft seal replacement only, see
DE Shaft Seal and Bearing Housing on
page 24. For disassembly of DE stage
or complete disassembly, see DE Stage
on page 21.
DE Stage
1. Remove the crossover pipe at connecting
À
anges (if not already removed).
2. Remove the DE tie-rod nuts and lift off the DE
end casing. Remove the end plate from the
end casing only if it needs to be replaced.
3. Remove the impeller housing.
4. Remove shaft locknut and impeller nut. This
step is identical to step 4 in
NDE Stage on
page 20
except nut threading is in the
opposite direction on this end of the respective
pump models:
KLRC-40 and 75
KLRC-125 to 950
Left Hand Thread
Right Hand Thread
CW to loosen
CCW to loosen
5. Remove impeller and note direction of blade
for reassembly.
Center Housing and NDE Stage
1. Remove NDE tie-rod nuts and lift off the center
housing with both sets of tie-rods.
1. Lift off the NDE impeller housing.
2. Lift the shaft with NDE impeller attached from
the NDE end casing.
3. Disassemble the shaft/impeller only if the
impeller locknut is not securely fastened and
indicates fuller inspection, or if either part
needs to be replaced.
Содержание KLRC Series
Страница 6: ...iv Table of Contents Manual 4804 Rev C p n 004804 0000 ...
Страница 33: ...27 08 Reassembly Manual 4804 Rev C p n 004804 0000 Figure 8 2 Bearing Driver Tool ...
Страница 34: ...28 08 Reassembly Manual 4804 Rev C p n 004804 0000 Figure 8 3 Foot Alignment Tool ...
Страница 37: ...31 09 Troubleshooting Manual 4804 Rev C p n 004804 0000 NOTES ...
Страница 38: ...32 Parts Lists and Assembly Drawings Manual 4804 Rev C p n 004804 0000 CROSS SECTION KLRC 40 AND KLRC 75 ...
Страница 42: ...36 Parts Lists and Assembly Drawings Manual 4804 Rev C p n 004804 0000 CROSS SECTION KLRC 125 TO KLRC 525 ...